UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

A High Frame Rate Wearable EIT System Using Active Electrode ASICs for Lung Respiration and Heart Rate Monitoring

Wu, Y; Jiang, D; Bardill, A; de Gelidi, S; Bayford, R; Demosthenous, A; (2018) A High Frame Rate Wearable EIT System Using Active Electrode ASICs for Lung Respiration and Heart Rate Monitoring. IEEE Transactions on Circuits and Systems I: Regular Papers , 65 (11) pp. 3810-3820. 10.1109/TCSI.2018.2858148. Green open access

[thumbnail of Wu_FINAL VERSION.pdf]
Preview
Text
Wu_FINAL VERSION.pdf - Accepted Version

Download (2MB) | Preview

Abstract

A high specification, wearable, electrical impedance tomography (EIT) system with 32 active electrodes is presented. Each electrode has an application specific integrated circuit (ASIC) mounted on a flexible printed circuit board, which is then wrapped inside a disposable fabric cover containing silver-coated electrodes to form the wearable belt. It is connected to a central hub that operates all the 32 ASICs. Each ASIC comprises a high-performance current driver capable of up to 6 mA p-p output, a voltage buffer for EIT and heart rate signal recording as well as contact impedance monitoring, and a sensor buffer that provides multi-parameter sensing. The ASIC was designed in a CMOS 0.35-μm high-voltage process technology. It operates from ±9 V power supplies and occupies a total die area of 3.9 mm^{2}. The EIT system has a bandwidth of 500 kHz and employs two parallel data acquisition channels to achieve a frame rate of 107 frames/s, the fastest wearable EIT system reported to date. Measured results show that the system has a measurement accuracy of 98.88% and a minimum EIT detectability of 0.86 Q/frame. Its successful operation in capturing EIT lung respiration and heart rate biosignals from a volunteer is demonstrated.

Type: Article
Title: A High Frame Rate Wearable EIT System Using Active Electrode ASICs for Lung Respiration and Heart Rate Monitoring
Location: Taormina, ITALY
Open access status: An open access version is available from UCL Discovery
DOI: 10.1109/TCSI.2018.2858148
Publisher version: https://doi.org/10.1109/TCSI.2018.2858148
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Electrodes, Tomography, Belts, Biomedical monitoring, Monitoring, Lung, Heart rate
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Electronic and Electrical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10059226
Downloads since deposit
509Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item