Deacon, L;
Jolly, S;
Keeble, F;
Wing, M;
Biskup, B;
Goldblatt, A;
Mazzoni, S;
(2017)
An electron spectrometer for proton driven plasma accelerated electrons at AWAKE: Predicted resolution of energy and emittance measurements.
In:
Proceedings of the 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD).
IEEE: Strasbourg, France.
Preview |
Text
summary.pdf - Accepted Version Download (507kB) | Preview |
Abstract
The Advanced Wakefield Experiment (AWAKE), to be constructed at CERN, will be the first experiment to demonstrate proton-driven plasma wakefield acceleration. The 400 GeV proton beam from the CERN SPS will excite a wakefield in a plasma cell several meters in length. To probe the plasma wakefield, electrons of 10-20 MeV will be injected into the wakefield following the head of the proton beam. Simulations indicate that electrons will be accelerated to GeV energies by the plasma wakefield. The AWAKE spectrometer is intended to measure both the peak energy and energy spread of these accelerated electrons. Under certain conditions it is also possible to use the spectrometer to measure the transverse beam emittance. The expected resolution of these measurements is investigated for various beam distributions, taking into account an optimised vacuum chamber and scintillator screen design and results of beam and optical tests.
Type: | Proceedings paper |
---|---|
Title: | An electron spectrometer for proton driven plasma accelerated electrons at AWAKE: Predicted resolution of energy and emittance measurements |
Event: | 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD) |
Location: | Strasbourg, France |
Dates: | 29 October 2016 - 05 November 2016 |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1109/NSSMIC.2016.8069746 |
Publisher version: | http://dx.doi.org/10.1109/NSSMIC.2016.8069746 |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Particle beams, Plasmas, Acceleration, Energy measurement, Measurement uncertainty, Plasma measurements, Uncertainty, AWAKE, plasma wakefield acceleration, electron spectrometer, emittance measurement |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences > Dept of Physics and Astronomy |
URI: | https://discovery.ucl.ac.uk/id/eprint/10038982 |
Archive Staff Only
View Item |