Browse by UCL Departments and Centres
A
Abbott, CA;
Chatwin, KE;
Foden, P;
Hasan, AN;
Sange, C;
Rajbhandari, SM;
Reddy, PN;
... Reeves, ND; + view all
(2019)
Innovative intelligent insole system reduces diabetic foot ulcer recurrence at plantar sites: a prospective, randomised, proof-of-concept study.
The Lancet Digital Health
, 1
(6)
e308-e318.
10.1016/s2589-7500(19)30128-1.
|
Ahmad, OF;
Lovat, LB;
(2019)
Artificial intelligence for colorectal polyp detection: are we ready for prime time?
Journal of Medical Artificial Intelligence
, 2
, Article 16. 10.21037/jmai.2019.09.02.
|
Ahmad, OF;
Soares, AS;
Mazomenos, E;
Brandao, P;
Vega, R;
Seward, E;
Stoyanov, D;
... Lovat, LB; + view all
(2019)
Artificial intelligence and computer-aided diagnosis in colonoscopy: current evidence and future directions.
[Review].
The Lancet Gastroenterology and Hepatology
, 4
(1)
pp. 71-80.
10.1016/S2468-1253(18)30282-6.
|
Ahmad, OF;
Stoyanov, D;
Lovat, LB;
(2019)
Human-machine Collaboration: Bringing Artificial Intelligence Into Colonoscopy.
Frontline Gastroenterology
, 10
(2)
pp. 198-199.
10.1136/flgastro-2018-101047.
|
Ahmad, Reem Hussain Ali;
(2019)
Nanoparticle Enhanced Radiotherapy.
Doctoral thesis (Ph.D), UCL (University College London).
|
Akintonde, A;
Grimes, H;
Moinuddin, S;
Sharma, RA;
McClelland, J;
Thielemans, K;
(2019)
EP-2067 Data driven region of interest respiratory surrogate signal extraction from CBCT data.
Presented at: 38th Annual Meeting of the European-Society-for-Radiotherapy-and-Oncology (ESTRO), Milan, Italy.
|
Akintonde, A;
Thielemans, K;
Sharma, R;
Mouches, P;
Mory, C;
Rit, S;
McClelland, J;
(2019)
Respiratory motion model derived from CBCT projection data.
In:
Proceedings of the 19th International Conference on the Use of Computers in Radiation Therapy.
ICCR
(In press).
|
Aksman, LM;
Scelsi, MA;
Marquand, AF;
Alexander, DC;
Ourselin, S;
Altmann, A;
for ADNI, .;
(2019)
Modeling longitudinal imaging biomarkers with parametric Bayesian multi-task learning.
Human Brain Mapping
, 40
(13)
pp. 3982-4000.
10.1002/hbm.24682.
|
Albelda Gimeno, L;
Martin, E;
Wright, O;
Treeby, B;
(2019)
Experimental assessment of skull aberration and transmission loss at 270 kHz for focused ultrasound stimulation of the primary visual cortex.
In:
Proceedings of the 2019 IEEE International Ultrasonics Symposium (IUS).
(pp. pp. 556-559).
IEEE: Glasgow, United Kingdom, United Kingdom.
|
Alles, EJ;
Desjardins, AE;
(2019)
Source Density Apodisation: Image Artefact Suppression through Source Pitch Non-Uniformity.
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
10.1109/tuffc.2019.2945636.
(In press).
|
Alshaikhi, J;
Doolan, PJ;
D'Souza, D;
Holloway, SM;
Amos, RA;
Royle, G;
(2019)
Impact of varying planning parameters on proton pencil beam scanning dose distributions in four commercial treatment planning systems.
Medical Physics
, 46
(3)
pp. 1150-1162.
10.1002/mp.13382.
|
Altmann, A;
Mourao-Miranda, J;
(2019)
Evidence for bias of genetic ancestry in resting state functional MRI.
In: Linguraru, Marius George and Grisan, Enrico, (eds.)
Proceedings of the IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019).
IEEE Xplore: New York, USA.
(In press).
|
Amir, Amalina;
(2019)
Making of Graphene Fibre Composites using Pressurised Gyration.
Doctoral thesis (Ph.D), UCL (University College London).
|
Ansari, R;
Zhang, EZ;
Desjardins, AE;
David, AL;
Beard, PC;
(2019)
Use of a flexible optical fibre bundle to interrogate a Fabry–Perot sensor for photoacoustic imaging.
Optics Express
, 27
(26)
pp. 37886-37899.
10.1364/OE.27.037886.
|
Anthis, AHC;
Tsolaki, E;
Didierlaurent, L;
Staubli, S;
Zboray, R;
Neels, A;
Dietrich, D;
... Herrmann, IK; + view all
(2019)
Nano-analytical characterization of endogenous minerals in healthy placental tissue: mineral distribution, composition and ultrastructure.
Analyst
, 144
(23)
pp. 6850-6857.
10.1039/c9an01312a.
|
Antonelli, M;
Cardoso, MJ;
Johnston, EW;
Appayya, MB;
Presles, B;
Modat, M;
Punwani, S;
(2019)
GAS: A genetic atlas selection strategy in multi-atlas segmentation framework.
Medical Image Analysis
, 52
pp. 97-108.
10.1016/j.media.2018.11.007.
|
Archetti, D;
Ingala, S;
Venkatraghavan, V;
Wottschel, V;
Young, AL;
Bellio, M;
Bron, EE;
... for EuroPOND Consortium, .; + view all
(2019)
Multi-study validation of data-driven disease progression models to characterize evolution of biomarkers in Alzheimer's disease.
Neuroimage Clinical
, 24
, Article 101954. 10.1016/j.nicl.2019.101954.
|
Ataka, A;
Stilli, A;
Konstantinova, J;
Wurdemann, HA;
Althoefer, K;
(2019)
Kinematic Control and Obstacle Avoidance for Soft Inflatable Manipulator.
In:
Towards Autonomous Robotic Systems.
(pp. pp. 52-64).
Springer: Cham, Switzerland.
|
Aughwane, R;
Ingram, E;
Johnstone, ED;
Salomon, LJ;
David, AL;
Melbourne, A;
(2019)
Placental MRI and its application to fetal intervention.
Prenatal Diagnosis
10.1002/pd.5526.
(In press).
|
Aughwane, R;
Schaaf, C;
Hutchinson, JC;
Virasami, A;
Zuluaga, MA;
Sebire, N;
Arthurs, OJ;
... David, AL; + view all
(2019)
Micro-CT and histological investigation of the spatial pattern of feto-placental vascular density.
Placenta
10.1016/j.placenta.2019.09.014.
(In press).
|
Avery, J;
Dowrick, T;
Witkowska-Wrobel, A;
Faulkner, M;
Aristovich, KY;
Holder, DS;
(2019)
Simultaneous EIT and EEG using frequency division multiplexing.
Physiological Measurement
, 40
(3)
, Article 034007. 10.1088/1361-6579/ab0bbc.
|
Aytac-Kipergil, E;
Alles, E;
Pauw, H;
Karia, J;
Noimark, S;
Desjardins, A;
(2019)
Versatile and scalable fabrication method for laser-generated focused ultrasound transducers.
Optics Letters
, 44
(24)
pp. 6005-6008.
10.1364/OL.44.006005.
|
B
Bailey, C;
Bourne, RM;
Siow, B;
Johnston, EW;
Brizmohun Appayya, M;
Pye, H;
Heavey, S;
... Panagiotaki, E; + view all
(2019)
VERDICT MRI validation in fresh and fixed prostate specimens using patient-specific moulds for histological and MR alignment.
NMR in Biomedicine
, Article e4073. 10.1002/nbm.4073.
(In press).
|
Bajada, CJ;
Trujillo-Barreto, NJ;
Parker, GJM;
Cloutman, LL;
Lambon Ralph, MA;
(2019)
A structural connectivity convergence zone in the ventral and anterior temporal lobes: Data-driven evidence from structural imaging.
Cortex
, 120
pp. 298-307.
10.1016/j.cortex.2019.06.014.
|
Bakaric, M;
Ivory, A;
Zeqiri, B;
Cox, BT;
Treeby, B;
(2019)
Measurement of the temperature-dependent speed of sound and change in Gruneisen parameter of tissue-mimicking materials.
In:
Proceedings of the 2019 IEEE International Ultrasonics Symposium (IUS).
(pp. pp. 1029-1032).
IEEE: Glasgow, Scotland, UK.
|
Bakaric, M;
Miloro, P;
Zeqiri, B;
Cox, BT;
Treeby, BE;
(2019)
The effect of curing temperature and time on the acoustic and optical properties of PVCP.
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
10.1109/TUFFC.2019.2947341.
(In press).
|
Bale, G;
Mitra, S;
de Roever, I;
Sokolska, M;
Price, D;
Bainbridge, A;
Gunny, R;
... Tachtsidis, I; + view all
(2019)
Oxygen dependency of mitochondrial metabolism indicates outcome of newborn brain injury.
Journal of Cerebral Blood Flow & Metabolism
, 39
(10)
pp. 2035-2047.
10.1177/0271678X18777928.
|
Bale, G;
Rajaram, A;
Kewin, M;
Morrison, L;
Bainbridge, A;
Liu, L;
Anazodo, U;
... Tachtsidis, I; + view all
(2019)
Multimodal measurements of brain tissue metabolism and perfusion in a neonatal model of hypoxic-ischaemic injury.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Bale, G;
Tachtsidis, I;
(2019)
The Use of Near‐Infrared Spectroscopy to Monitor Tissue Oxygenation, Metabolism and Injury in Low Resource Settings.
In: Atkinson, K and Mabey, D, (eds.)
Revolutionizing Tropical Medicine: Point-of-Care Tests, New Imaging Technologies and Digital Health.
(pp. 344-359).
Wiley-Blackwell: Hoboken, NJ, USA.
|
Bano, S;
Vasconcelos, F;
Amo, MT;
Dwyer, G;
Gruijthuijsen, C;
Deprest, J;
Ourselin, S;
... Stoyanov, D; + view all
(2019)
Deep Sequential Mosaicking of Fetoscopic Videos.
In:
Proceedings of the MICCAI 2019: 22nd International Conference on Medical Image Computing and Computer Assisted Intervention.
(pp. pp. 311-319).
Springer: Shenzhen, China.
|
Barkhof, F;
Parker, GJM;
(2019)
Reproducing Fingerprints: A Step toward Clinical Adoption.
Radiology
, 292
(2)
pp. 438-439.
10.1148/radiol.2019191146.
|
Battiston, M;
Schneider, T;
Grussu, F;
Yiannakas, MC;
Prados, F;
De Angelis, F;
Gandini Wheeler-Kingshott, CAM;
(2019)
Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI.
Magnetic Resonance in Medicine
, 82
(3)
pp. 1025-1040.
10.1002/mrm.27792.
|
Beard, P;
Anastasio, M;
Oraevsky, AA;
Wang, LV;
(2019)
Special Section Guest Editorial: Celebrating the Exponential Growth of Optoacoustic/Photoacoustic Imaging.
Journal of Biomedical Optics
, 24
(12)
, Article 121901. 10.1117/1.JBO.24.12.121901.
|
Beasley, D;
Eiben, B;
Doran, S;
Darcy, J;
Petts, J;
Patel, R;
White, M;
... McClelland, JR; + view all
(2019)
Secure-DICOM-Uploader: A platform for anonymising and transferring imaging data from hospital sites to remote repositories.
In:
Proceedings of the 19th International Conference on the Use of Computers in Radiation Therapy 2019.
ICCR: Montreal, Canada.
|
Beaton, L;
Tregidgo, HFJ;
Znati, SA;
Forsyth, S;
Clarkson, MJ;
Bandula, S;
Chouhan, M;
... Sharma, RA; + view all
(2019)
VEROnA Protocol: A Pilot, Open-Label, Single-Arm, Phase 0, Window-of-Opportunity Study of Vandetanib-Eluting Radiopaque Embolic Beads (BTG-002814) in Patients With Resectable Liver Malignancies.
JMIR Research Protocols
, 8
(10)
, Article e13696. 10.2196/13696.
|
Bennett, OF;
Kanber, B;
Hoskote, C;
Cardoso, MJ;
Ourselin, S;
Duncan, JS;
Winston, GP;
(2019)
Learning to see the invisible: A data-driven approach to finding the underlying patterns of abnormality in visually normal brain magnetic resonance images in patients with temporal lobe epilepsy.
Epilepsia
10.1111/epi.16380.
(In press).
|
Bergen, AA;
Arya, S;
Koster, C;
Pilgrim, MG;
Wiatrek-Moumoulidis, D;
Van der Spek, P;
Hauck, SM;
... Lengyel, I; + view all
(2019)
On the origin of proteins in human drusen: The meet, greet and stick hypothesis.
Progress in Retinal and Eye Research
, 70
pp. 558-84.
10.1016/j.preteyeres.2018.12.003.
|
Bertholet, J;
Eiben, B;
Menten, M;
Tran, EH;
Hawkes, DJ;
Wetscherek, A;
Nill, S;
... Oelfke, U; + view all
(2019)
In silico validation of motion-including dose reconstruction for MR-guided lung SBRT using a patient specific motion model.
In:
Proceedings of the 19th International Conference on the Use of Computers in Radiation Therapy.
ICCR
|
Bertholet, J;
Knopf, A-C;
Eiben, B;
McClelland, JR;
Grimwood, A;
Harris, E;
Menten, MJ;
... Oelfke, U; + view all
(2019)
Real-time intrafraction motion monitoring in external beam radiotherapy.
Physics in Medicine & Biology
10.1088/1361-6560/ab2ba8.
(In press).
|
Besleaga, T;
Badiani, S;
Lloyd, G;
Toschi, N;
Canichella, A;
Demosthenous, A;
Lambiase, PD;
(2019)
Non-Invasive Detection of Mechanical Alternans Utilizing Photoplethysmography.
IEEE Journal of Biomedical and Health Informatics
, 23
(6)
2409 -2416.
10.1109/JBHI.2018.2882550.
|
Besleaga, T;
Canichella, A;
Toschi, N;
Demosthenous, A;
Lambiase, PD;
Orini, M;
(2019)
Detecting Mechanical Alternans Utilizing Photoplethysmography.
In: Dassen, Willem and Heijman, Jordi, (eds.)
Proceedings of Computers in Cardiology (CinC) 2018.
IEEE Xplore: New York, USA.
|
Biondetti, E;
Rojas-Villabona, A;
Sokolska, M;
Pizzini, FB;
Jäger, HR;
Thomas, DL;
Shmueli, K;
(2019)
Investigating the oxygenation of brain arteriovenous malformations using quantitative susceptibility mapping.
NeuroImage
10.1016/j.neuroimage.2019.05.014.
(In press).
|
Biondetti, Emma;
(2019)
Optimising MRI magnetic susceptibility mapping for the study of brain arteriovenous malformations.
Doctoral thesis (Ph.D), UCL (University College London).
|
Blasi, A;
Lloyd-Fox, S;
Katus, L;
Elwell, CE;
(2019)
fNIRS for tracking brain development in the context of global health projects.
Photonics
, 6
(3)
10.3390/photonics6030089.
|
Bocchetta, M;
Iglesias, JE;
Cash, DM;
Warren, JD;
Rohrer, JD;
(2019)
Amygdala subnuclei are differentially affected in the different genetic and pathological forms of frontotemporal dementia.
Alzheimer's and Dementia: Diagnosis, Assessment and Disease Monitoring
, 11
pp. 136-141.
10.1016/j.dadm.2018.12.006.
(In press).
|
Bocchetta, M;
Iglesias, JE;
Russell, L;
Greaves, CV;
Marshall, C;
Scelsi, MA;
Cash, D;
... Rohrer, J; + view all
(2019)
Segmentation of medial temporal subregions reveals early right-sided involvement in semantic variant PPA.
Alzheimer's Research and Therapy
, 11
, Article 41. 10.1186/s13195-019-0489-9.
|
Bonet-Carne, E;
Johnston, E;
Daducci, A;
Jacobs, JG;
Freeman, A;
Atkinson, D;
Hawkes, DJ;
... Panagiotaki, E; + view all
(2019)
VERDICT‐AMICO: Ultrafast fitting algorithm for non‐invasive prostate microstructure characterization.
NMR in Biomedicine
, 32
(1)
, Article e4019. 10.1002/nbm.4019.
|
Bonfanti, M;
Franzetti, G;
Maritati, G;
Homer-Vanniasinkam, S;
Balabani, S;
Díaz-Zuccarini, V;
(2019)
Patient-specific haemodynamic simulations of complex aortic dissections informed by commonly available clinical datasets.
Medical Engineering & Physics
, 71
pp. 45-55.
10.1016/j.medengphy.2019.06.012.
|
Bonfanti, Mirko;
(2019)
Personalised haemodynamic simulations of aortic dissection: towards clinical translation.
Doctoral thesis (Ph.D), UCL (University College London).
|
Borges, P;
Sudre, C;
Varsavsky, T;
Thomas, D;
Drobnjak, I;
Ourselin, S;
Cardoso, MJ;
(2019)
Physics-informed brain MRI segmentation.
In: Burgos, N and Gooya, A and Svoboda, D, (eds.)
SASHIMI 2019: Simulation and Synthesis in Medical Imaging.
(pp. pp. 100-109).
Springer: Shenzhen, China.
|
Bowden, W;
Hobson, R;
Hill, IR;
Vianello, A;
Schioppo, M;
Silva, A;
Margolis, HS;
... Gill, P; + view all
(2019)
A pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock.
Scientific Reports
, 9
, Article 11704. 10.1038/s41598-019-48168-3.
|
Bragman, FJS;
Tanno, R;
Ourselin, S;
Alexander, DC;
Cardoso, MJ;
(2019)
Learning task-specific and shared representations in medical imaging.
In:
Medical Image Computing and Computer Assisted Intervention – MICCAI 2019.
(pp. pp. 374-383).
Springer Nature: Cham, Switzerland.
|
Brandao, P;
Mazomenos, E;
Stoyanov, D;
(2019)
Widening siamese architectures for stereo matching.
Pattern Recognition Letters
, 120
pp. 75-81.
10.1016/j.patrec.2018.12.002.
|
Bray, TJP;
Karsa, A;
Bainbridge, A;
Sakai, N;
Punwani, S;
Hall-Craggs, MA;
Shmueli, K;
(2019)
Association of bone mineral density and fat fraction with magnetic susceptibility in inflamed trabecular bone.
Magnetic Resonance in Medicine
10.1002/mrm.27634.
(In press).
|
Breen-Norris, J;
Siow, B;
Hipwell, B;
Roberts, T;
Lythgoe, M;
Ianus, A;
Alexander, D;
(2019)
Using Diffusion-Diffusion Exchange Spectroscopy to observe diffusion exchange in yeast.
Diffusion Fundamentals
, 31
, Article 3.
|
Brenner, T;
Munro, PRT;
Krüger, B;
Kienle, A;
(2019)
Two-dimensional simulation of optical coherence tomography images.
Scientific Reports
, 9
, Article 12189. 10.1038/s41598-019-48498-2.
|
Brigadoi, S;
Galderisi, A;
Pieropan, E;
Cooper, RJ;
Cutini, S;
Baraldi, E;
Cobelli, C;
... Trevisanuto, D; + view all
(2019)
Mapping hemodynamic changes during hypoglycemia in the very preterm neonatal brain: Preliminary results.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Brigadoi, S;
Ganglani, A;
Zhao, H;
Cooper, RJ;
(2019)
Integrating motion sensing and wearable, modular high-density diffuse optical tomography: Preliminary results.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Brombal, L;
Kallon, G;
Jiang, J;
Savvidis, S;
De Coppi, P;
Urbani, L;
Forty, E;
... Endrizzi, M; + view all
(2019)
Monochromatic Propagation-Based Phase-Contrast Microscale Computed-Tomography System with a Rotating-Anode Source.
Physical Review Applied
, 11
, Article 034004. 10.1103/PhysRevApplied.11.034004.
|
Brown, CN;
Green, BD;
Thompson, RB;
den Hollander, AI;
Lengyel, I;
Acar, IE;
Ajana, S;
... Zumbansen, M; + view all
(2019)
Metabolomics and Age-Related Macular Degeneration.
Metabolites
, 9
(1)
, Article 4. 10.3390/metabo9010004.
|
Brown, MD;
Zhang, EZ;
Treeby, BE;
Beard, PC;
Cox, BT;
(2019)
Reverberant cavity photoacoustic imaging.
Optica
, 6
(6)
pp. 821-822.
10.1364/OPTICA.6.000821.
|
Brown, P;
Tan, A-C;
El-Esawi, MA;
Liehr, T;
Blanck, O;
Gladue, DP;
Almeida, GMF;
... Shalchyan, V; + view all
(2019)
Large expert-curated database for benchmarking document similarity detection in biomedical literature search.
Database
pp. 1-66.
10.1093/database/baz085.
|
Brown, W;
Chowdhury, A;
Kanber, B;
Prados Carrasco, F;
Eshaghi, A;
Sudre, CH;
Pardini, M;
... Chard, DT; + view all
(2019)
Magnetisation transfer ratio abnormalities in primary and secondary progressive multiple sclerosis.
Multiple Sclerosis Journal
(In press).
|
Brown, W;
Prados Carrasco, F;
Eshaghi, A;
Sudre, CH;
Button, T;
Pardini, M;
Samson, RS;
... Chard, DT; + view all
(2019)
Periventricular magnetisation transfer ratio abnormalities in multiple sclerosis improve after alemtuzumab.
Multiple Sclerosis Journal
10.1177/1352458519852093.
(In press).
|
Brownlee, WJ;
Altmann, DR;
Prados Carrasco, F;
Miszkiel, KA;
Eshaghi, A;
Wheeler-Kingshott, C;
Barkhof, F;
(2019)
Early imaging predictors of long-term outcomes in relapse-onset multiple sclerosis.
Brain
, 142
(8)
pp. 2276-2287.
10.1093/brain/awz156.
|
Brownlee, WJ;
Solanky, B;
Prados, F;
Yiannakas, M;
Da Mota, P;
Riemer, F;
Cardoso, MJ;
... Ciccarelli, O; + view all
(2019)
Cortical grey matter sodium accumulation is associated with disability and secondary progressive disease course in relapse-onset multiple sclerosis.
Journal of Neurology, Neurosurgery & Psychiatry
10.1136/jnnp-2018-319634.
(In press).
|
Bulgarelli, C;
Blasi, A;
de Klerk, CCJM;
Richards, JE;
Hamilton, A;
Southgate, V;
(2019)
Fronto-temporoparietal connectivity and self-awareness in 18-month-olds: A resting state fNIRS study.
Developmental Cognitive Neuroscience
, 38
, Article 100676. 10.1016/j.dcn.2019.100676.
|
Bussu, G;
Jones, EJH;
Charman, T;
Johnson, MH;
Buitelaar, JK;
Blasi, A;
Baron-Cohen, S;
... Volein, A; + view all
(2019)
Latent trajectories of adaptive behaviour in infants at high and low familial risk for autism spectrum disorder.
Molecular Autism
, 10
(1)
, Article 13. 10.1186/s13229-019-0264-6.
|
C
Callaghan, R;
Alexander, DC;
Zhang, H;
Palombo, M;
(2019)
Contextual fibre growth to generate realistic axonal packing for diffusion MRI simulation.
Presented at: 25th Annual Meeting of the Organization for Human Brain Mapping (2019 OHBM), Rome, Italy.
|
Callaghan, R;
Alexander, DC;
Zhang, H;
Palombo, M;
(2019)
Contextual fibre growth to generate realistic axonal packing for diffusion MRI simulation.
In: Chung, A and Gee, J and Yushkevich, P and Bao, S, (eds.)
IPMI 2019: Information Processing in Medical Imaging.
(pp. 429-440).
Springer, Cham: Cham, Switzerland.
|
Calvet, L;
Bourdin, P;
Prados, F;
(2019)
Immersive technologies in higher education: Applications, challenges, and good practices.
In:
Proceedings of the 2019 3rd International Conference on Education and E-Learning.
(pp. pp. 95-99).
Association for Computing Machinery (ACM)
|
Canas, LS;
Sudre, CH;
De Vita, E;
Nihat, A;
Mok, TH;
Slattery, CF;
Paterson, RW;
... Modat, M; + view all
(2019)
Prion disease diagnosis using subject-specific imaging biomarkers within a multi-kernel Gaussian process.
NeuroImage: Clinical
, Article 102051. 10.1016/j.nicl.2019.102051.
(In press).
|
Caplan, I;
De Jager, K;
Al'joboori, Y;
Duffell, L;
Vanhoestenberghe, A;
Loureiro, R;
(2019)
Stimulation induced biopotential amplifier saturation due to common mode voltage.
Presented at: BioMedEng19, London, UK.
|
Carnevali, L;
Mancini, M;
Koenig, J;
Makovac, E;
Watson, DR;
Meeten, F;
Critchley, HD;
(2019)
Cortical morphometric predictors of autonomic dysfunction in generalized anxiety disorder.
Autonomic Neuroscience
, 217
pp. 41-48.
10.1016/j.autneu.2019.01.001.
|
Carr, E;
Mackle, EC;
Finlay, MC;
Mosse, CA;
Coote, JM;
Papakonstantinou, I;
Desjardins, AE;
(2019)
Optical interferometric temperature sensors for intravascular blood flow measurements.
In: Amelink, A and Nadkarni, SK, (eds.)
Novel Biophotonics Techniques and Applications V.
SPIE: Munich, Germany.
|
Castillo-Quan, JI;
Tain, LS;
Kinghorn, KJ;
Li, L;
Grönke, S;
Hinze, Y;
Blackwell, TK;
... Partridge, L; + view all
(2019)
A triple drug combination targeting components of the nutrient-sensing network maximizes longevity.
Proceedings of the National Academy of Sciences of the United States of America
, 116
(42)
pp. 20817-20819.
10.1073/pnas.1913212116.
|
Chalia, M;
Dempsey, LA;
Cooper, RJ;
Lee, C-W;
Gibson, AP;
Hebden, JC;
Austin, T;
(2019)
Diffuse optical tomography for the detection of perinatal stroke at the cot side: a pilot study.
Pediatric Research
, 85
pp. 1001-1007.
10.1038/s41390-018-0263-x.
|
Chan, Oliver;
(2019)
Do subchondral bone chemical changes predict ankle osteoarthritis?
Doctoral thesis (M.D(Res)), UCL (University College London).
|
Chapman, CAR;
Aristovich, K;
Donega, M;
Fjordbakk, CT;
Stathopoulou, T-R;
Viscasillas, J;
Avery, J;
... Holder, D; + view all
(2019)
Electrode fabrication and interface optimization for imaging of evoked peripheral nervous system activity with electrical impedance tomography (EIT).
Journal of Neural Engineering
, 16
(1)
, Article 016001. 10.1088/1741-2552/aae868.
|
Chapman, CAR;
Smith, TM;
Kelly, M;
Avery, J;
Rouanet, T;
Aristovich, K;
Chew, DJ;
(2019)
Optimisation of bioimpedance measurements of neuronal activity with an ex vivo preparation of Cancer pagurus peripheral nerves.
Journal of Neuroscience Methods
, 327
, Article 108322. 10.1016/j.jneumeth.2019.108322.
|
Charalambous, T;
Tur, C;
Prados, F;
Kanber, B;
Chard, DT;
Ourselin, S;
Clayden, JD;
... Toosy, AT; + view all
(2019)
Structural network disruption markers explain disability in multiple sclerosis.
Journal of Neurology, Neurosurgery and Psychiatry
, 90
(2)
pp. 219-226.
10.1136/jnnp-2018-318440.
|
Christopher, E;
Poon, MTC;
Glancz, LJ;
Hutchinson, PJ;
Kolias, AG;
Brennan, PM;
Afshari, FT;
... Zaben, M; + view all
(2019)
Outcomes following surgery in subgroups of comatose and very elderly patients with chronic subdural hematoma.
Neurosurgical Review
, 42
(2)
427`-431.
10.1007/s10143-018-0979-4.
|
Chu, KY;
Cooke, R;
Van den Heuvel, F;
Mukherjee, S;
Hawkins, MA;
(2019)
Impact of abdominal compression on setup error and image matching during radical abdominal radiotherapy.
Technical Innovations & Patient Support in Radiation Oncology
, 12
pp. 28-33.
10.1016/j.tipsro.2019.11.003.
|
Cochran, JM;
Busch, DR;
Lin, L;
Minkoff, DL;
Schweiger, M;
Arridge, S;
Yodh, AG;
(2019)
Hybrid time-domain and continuous-wave diffuse optical tomography instrument with concurrent, clinical magnetic resonance imaging for breast cancer imaging.
Journal of Biomedical Optics
, 24
(5)
, Article 051409. 10.1117/1.JBO.24.5.051409.
|
Colchester, R;
Alles, E;
Desjardins, A;
(2019)
A Directional Fibre Optic Ultrasound Transmitter Based on a Reduced Graphene Oxide and Polydimethylsiloxane Composite.
Applied Physics Letters
, 114
(11)
10.1063/1.5089750.
|
Colchester, R;
Alles, E;
Dwyer, G;
Maneas, E;
Stoyanov, D;
Desjardins, A;
(2019)
Large area all-optical ultrasound imaging using robotic control.
In:
Proceedings of the SPIE 11077, Opto-Acoustic Methods and Applications in Biophotonics IV.
SPIE: Munich, Germany.
|
Colchester, R;
Little, C;
Dwyer, G;
Noimark, S;
Alles, E;
Zhang, E;
Loder, CD;
... Desjardins, A; + view all
(2019)
All-Optical Rotational Ultrasound Imaging.
Scientific Reports
, 9
, Article 5576. 10.1038/s41598-019-41970-z.
|
Colijn, JM;
Hollander, AID;
Demirkan, A;
Cougnard-Grégoire, A;
Verzijden, T;
Kersten, E;
Meester, MA;
... E3 Consortium and EYE-RISK Consortium, .; + view all
(2019)
Increased High Density Lipoprotein-levels associated with Age-related Macular degeneration. Evidence from the EYE-RISK and E3 Consortia.
Ophthalmology
, 126
(3)
pp. 393-406.
10.1016/j.ophtha.2018.09.045.
|
Collorone, S;
Cawley, N;
Grussu, F;
Prados, F;
Tona, F;
Calvi, A;
Kanber, B;
... Ciccarelli, O; + view all
(2019)
Reduced neurite density in the brain and cervical spinal cord in relapsing–remitting multiple sclerosis: A NODDI study.
Multiple Sclerosis Journal
10.1177/1352458519885107.
(In press).
|
Collorone, S;
Prados, F;
Hagens, MH;
Tur, C;
Kanber, B;
Sudre, CH;
Lukas, C;
... MAGNIMS Study Group, .; + view all
(2019)
Single-subject structural cortical networks in clinically isolated syndrome.
Multiple Sclerosis Journal
10.1177/1352458519865739.
(In press).
|
Convery, RS;
Jiao, J;
Clarke, MTM;
Moore, KM;
Koriath, CAM;
Woollacott, IOC;
Weston, PSJ;
... Rohrer, JD; + view all
(2019)
Longitudinal (¹⁸F)AV-1451 PET imaging in a patient with frontotemporal dementia due to a Q351R MAPT mutation.
Journal of Neurology, Neurosurgery & Psychiatry
10.1136/jnnp-2019-320904.
(In press).
|
Coote, J;
Alles, EJ;
Noimark, S;
Mosse, CA;
Little, CD;
Loder, CD;
David, AL;
... Desjardins, AE; + view all
(2019)
Dynamic physiological temperature and pressure sensing with phase-resolved low-coherence interferometry.
Optics Express
, 27
(4)
pp. 5641-5654.
10.1364/OE.27.005641.
|
Cottenden, A;
(2019)
Incontinence: The engineering challenge.
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, 233
(1)
pp. 3-6.
10.1177/0954411918807991.
|
Cottenden, A;
Macaulay, M;
(2019)
An investigation of laboratory test methods for predicting the in-use leakage performance of urine-absorbing aids in nursing homes.
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, 233
(1)
pp. 23-34.
10.1177/0954411918792385.
|
D
D'Ettorre, C;
Stilli, A;
Dwyer, G;
Tran, M;
Stoyanov, D;
(2019)
Autonomous Pick-And-Place of a Novel Robotic Surgery Imaging Rail Using the dVRK Platform.
In:
Proceedings of the 12th Hamlyn Symposium on Medical Robotics 2019.
(pp. pp. 19-20).
The Hamlyn Centre (Imperial College London)
|
Davis, AT;
Muscat, S;
Palmer, AL;
Buckle, D;
Earley, J;
Williams, MGJ;
Nisbet, A;
(2019)
Radiation dosimetry changes in radiotherapy treatment plans for adult patients arising from the selection of the CT image reconstruction kernel.
BJR|Open
, 1
(1)
, Article 20190023. 10.1259/bjro.20190023.
|
De Jager, K;
Mentink, M;
Lancashire, H;
Al-Ajam, Y;
Taylor, S;
Vanhoestenberghe, A;
(2019)
Characterisation of a multi-channel multiplexed EMG recording system: towards realising variable electrode configurations.
Presented at: BioCAS 2019: Biomedical Circuits and Systems Conference, Nara, Japan.
|
De Jager, K;
Mentink, M;
Lancashire, H;
Taylor, S;
Vanhoestenberghe, A;
(2019)
Simultaneous power transfer and bidirectional serial communication for implantable electronics.
Presented at: BioMedEng19, London, UK.
|
de Klerk, CCJM;
Bulgarelli, C;
Hamilton, A;
Southgate, V;
(2019)
Selective facial mimicry of native over foreign speakers in preverbal infants.
Journal of Experimental Child Psychology
, 183
pp. 33-47.
10.1016/j.jecp.2019.01.015.
|
De Roever, I;
Vezyroglou, A;
Hebden, P;
Thornton, R;
Worley, A;
Alves, M;
Dean, E;
... Tachtsidis, I; + view all
(2019)
A new multichannel broadband NIRS system for quantitative monitoring of brain hemodynamics and metabolism during seizures.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
de Roever, Janet Isabel;
(2019)
Development of a portable multi-channel broadband near infrared spectroscopy instrument to measure brain tissue oxygenation and metabolism
during functional activation and seizures.
Doctoral thesis (Ph.D), UCL (University College London).
|
Demetriou, E;
Tachrount, M;
Ellis, M;
LINEHAN, J;
Brandner, S;
Shmueli, K;
Farrow, M;
(2019)
A multiparametric study of prion disease.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition 2019.
(pp. p. 2613).
ISMRM: Montréal, QC, Canada.
|
den Haan, J;
Csinscik, L;
Parker, T;
Paterson, RW;
Slattery, CF;
Foulkes, A;
Bouwman, FH;
... Yong, KXX; + view all
(2019)
Retinal thickness as potential biomarker in posterior cortical atrophy and typical Alzheimer's disease.
Alzheimer's Research and Therapy
, 11
, Article 62. 10.1186/s13195-019-0516-x.
|
Di Lorenzo, R;
Pirazzoli, L;
Blasi, A;
Bulgarelli, C;
Hakuno, Y;
Minagawa, Y;
Brigadoi, S;
(2019)
Recommendations for motion correction of infant fNIRS data applicable to multiple data sets and acquisition systems.
NEUROIMAGE
, 200
pp. 511-527.
10.1016/j.neuroimage.2019.06.056.
|
Di Lorenzo, R;
Blasi, A;
Junge, C;
Van den Boomen, C;
Van Rooijen, R;
Kemner, C;
(2019)
Brain Responses to Faces and Facial Expressions in 5-Month-Olds: An fNIRS Study.
Frontiers in Psychology
, 10
, Article 1240. 10.3389/fpsyg.2019.01240.
|
Dickie, BR;
Vandesquille, M;
Ulloa, J;
Boutin, H;
Parkes, LM;
Parker, GJM;
(2019)
Water-exchange MRI detects subtle blood-brain barrier breakdown in Alzheimer's disease rats.
NeuroImage
, 184
pp. 349-358.
10.1016/j.neuroimage.2018.09.030.
|
Dimitrakakis, E;
Dwyer, G;
Marcus, H;
Dorward, N;
Stoyanov, D;
(2019)
Towards the Development of a Novel Handheld Robotic Tool for the Expanded Endoscopic Endonasal Approach.
In:
CRAS 2019 Proceedings of the 9th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery.
CRAS: Genoa, Italy.
|
Djurabekova, N;
Goldberg, A;
Hauptmann, A;
Hawkes, D;
Long, G;
Lucka, F;
Betcke, M;
(2019)
Application of Proximal Alternating Linearized Minimization (PALM) and inertial PALM to dynamic 3D CT.
In:
Proceedings of SPIE - The International Society for Optical Engineering.
SPIE: Philadelphia, United States.
|
Doherty, S;
Vanhoestenberghe, A;
Duffell, L;
Hamid, R;
Knight, S;
(2019)
A Urodynamic Comparison of Neural Targets for Transcutaneous Electrical Stimulation to Acutely Suppress Detrusor Contractions Following Spinal Cord Injury.
Frontiers in Neuroscience
, 13
, Article 1360. 10.3389/fnins.2019.01360.
|
Doherty, S;
Vanhoestenberghe, A;
Hamid, R;
Knight, S;
(2019)
A Retrospective Analysis of the Presence of Bladder Sensation Following Spinal Cord Injury.
In:
Proceedings of 49th International Continence Society (ICS) Annual Meeting.
(pp. p. 378).
ICS: Gothenburg, Sweden.
|
Doherty, Sean Patrick;
(2019)
Investigation of Transcutaneous Neuromodulation Techniques and Development of a Wearable Device for Control of the Bladder following Spinal Cord Injury.
Doctoral thesis (Ph.D), UCL (University College London).
|
Donadoni, F;
Bonfanti, M;
Pichardo-Almarza, C;
Homer-Vanniasinkam, S;
Dardik, A;
Díaz-Zuccarini, V;
(2019)
An in silico study of the influence of vessel wall deformation on neointimal hyperplasia progression in peripheral bypass grafts.
Medical Engineering & Physics
, 74
pp. 137-145.
10.1016/j.medengphy.2019.09.011.
|
Donaldson, N;
(2019)
Killing the goose.
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, 233
(1)
pp. 135-137.
10.1177/0954411917740168.
|
Dong, Z;
Guo, Z;
Lee, KH;
Fang, G;
Tang, WL;
Chang, HC;
Chan, DTM;
(2019)
High-Performance Continuous Hydraulic Motor for MR Safe Robotic Teleoperation.
IEEE Robotics and Automation Letters
, 4
(2)
pp. 1964-1971.
10.1109/LRA.2019.2899189.
|
Dong, L;
Wijesinghe, P;
Sampson, DD;
Kennedy, BF;
Munro, PRT;
Oberai, AA;
(2019)
Volumetric quantitative optical coherence elastography with an iterative inversion method.
Biomedical Optics Express
, 10
(2)
pp. 384-398.
10.1364/BOE.10.000384.
|
Dong, T;
Weheliye, WH;
Angeli, P;
(2019)
Laser induced fluorescence studies on the distribution of surfactants during drop/interface coalescence.
Physics of Fluids
, 31
, Article 012106. 10.1063/1.5059554.
|
Doshi, A;
Castellazzi, G;
Muhlert, N;
Alahmadi, A;
Prados, F;
Wheeler-Kingshott, C;
Ciccarelli, O;
(2019)
180 Cognitive diagnostic criteria lead to distinct patterns of functional connectivity in secondary progressive MS.
Presented at: Annual Meeting of the Association-of-British-Neurologists (ABN), Edinburgh, Scotland.
|
Downey, D;
Brigadoi, S;
Trevithick, L;
Elliott, R;
Elwell, C;
McAllister-Williams, RH;
Anderson, IM;
(2019)
Frontal haemodynamic responses in depression and the effect of electroconvulsive therapy.
Journal of Psychopharmacology
, 33
(8)
pp. 1003-1014.
10.1177/0269881119858313.
|
Dragojević, T;
Vidal Rosas, EE;
Hollmann, JL;
Culver, JP;
Justicia, C;
Durduran, T;
(2019)
High-density speckle contrast optical tomography of cerebral blood flow response to functional stimuli in the rodent brain.
Neurophotonics
, 6
(4)
, Article 045001. 10.1117/1.NPh.6.4.045001.
|
Dravida, S;
Ono, Y;
Noah, JA;
Zhang, X;
Hirsch, J;
(2019)
Co-localization of theta-band activity and hemodynamic responses during face perception: simultaneous electroencephalography and functional near-infrared spectroscopy recordings.
Neurophotonics
, 6
(4)
, Article 045002. 10.1117/1.NPh.6.4.045002.
|
Duffell, LD;
Paddison, S;
Alahmary, AF;
Donaldson, N;
Burridge, J;
(2019)
The effects of FES cycling combined with virtual reality racing biofeedback on voluntary function after incomplete SCI: a pilot study.
Journal of NeuroEngineering and Rehabilitation
, 16
, Article 149. 10.1186/s12984-019-0619-4.
|
Dwyer, G;
Alles, E;
Colchester, R;
Maneas, E;
Ourselin, S;
Vercauteren, T;
Deprest, J;
... Stoyanov, D; + view all
(2019)
Robotic Control of All-Optical Ultrasound Imaging.
In: Scabini, S, (ed.)
Proceedings of the 9th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery.
(pp. pp. 48-49).
CRAS: Genoa, Italy.
|
Dwyer, G;
Colchester, RJ;
Alles, EJ;
Maneas, E;
Ourselin, S;
Vercauteren, T;
Deprest, J;
... Stoyanov, D; + view all
(2019)
Robotic Control of a Multi-Modal Rigid Endoscope Combining Optical Imaging with All-Optical Ultrasound.
In: Dudek, Gregory, (ed.)
Proceedings of the International Conference on Robotics and Automation (ICRA 2019).
(pp. pp. 3882-3888).
IEEE: Montreal, QC, Canada, Canada.
|
E
Ebner, M;
Patel, P;
Atkinson, D;
Caselton, L;
Taylor, S;
Bainbridge, A;
Ourselin, S;
... Vercauteren, T; + view all
(2019)
Reconstruction-based super-resolution for high-resolution abdominal MRI: A preliminary study.
In:
Proceedings of the ISMRM 27th Annual Meeting and Exhibition.
International Society for Magnetic Resonance in Medicine (ISMRM): Montreal, Canada.
|
Ebner, M;
Patel, PA;
Atkinson, D;
Caselton, L;
Firmin, L;
Amin, Z;
Bainbridge, A;
... Vercauteren, T; + view all
(2019)
Super-resolution for upper abdominal MRI: Acquisition and post-processing protocol optimization using brain MRI control data and expert reader validation.
Magnetic Resonance in Medicine
, 82
(5)
pp. 1905-1919.
10.1002/mrm.27852.
|
Ebner, M;
Wang, G;
Li, W;
Aertsen, M;
Patel, PA;
Aughwane, R;
Melbourne, A;
... Vercauteren, T; + view all
(2019)
An automated framework for localization, segmentation and super-resolution reconstruction of fetal brain MRI.
NeuroImage
, Article 116324. 10.1016/j.neuroimage.2019.116324.
(In press).
|
Ebner, Michael;
(2019)
Volumetric MRI Reconstruction from 2D Slices in the Presence of Motion.
Doctoral thesis (Ph.D), UCL (University College London).
|
Eden, D;
Gros, C;
Badji, A;
Dupont, SM;
De Leener, M;
Maranzano, J;
Zhuoquiong, R;
... Cohen-Adad, J; + view all
(2019)
Spatial distribution of multiple sclerosis lesions in the cervical spinal cord.
Brain
, 142
(3)
pp. 633-646.
10.1093/brain/awy352.
|
Ehrhardt, MJ;
Markiewicz, P;
Schönlieb, C-B;
(2019)
Faster PET reconstruction with non-smooth priors by randomization and preconditioning.
Physics in Medicine & Biology
, 64
(22)
, Article 225019. 10.1088/1361-6560/ab3d07.
|
Eiben, B;
Bertholet, J;
Tran, EH;
Wetscherek, A;
Oelfke, U;
McClelland, J;
(2019)
Geometric accuracy of surrogate-driven respiratory motion models for MR-guided lung radiotherapy.
In:
Proceedings of the 19th International Conference on the Use of Computers in Radiation Therapy.
ICCR
|
Eshaghi, A;
Kievit, RA;
Prados Carrasco, F;
Sudre, C;
Nicholas, J;
Cardoso, MJ;
Chan, D;
... Ciccarelli, O; + view all
(2019)
Applying causal models to explore the mechanism of action of simvastatin in progressive multiple sclerosis.
Proceedings of the National Academy of Sciences of The United States of America (PNAS)
, 116
(22)
10.1073/pnas.1818978116.
|
Everson, M;
Herrera, LCGP;
Li, W;
Luengo, IM;
Ahmad, O;
Banks, M;
Magee, C;
... Haidry, RJ; + view all
(2019)
Artificial intelligence for the real-time classification of intrapapillary capillary loop patterns in the endoscopic diagnosis of early oesophageal squamous cell carcinoma: A proof-of-concept study.
United European Gastroenterology Journal
, 7
(2)
pp. 297-306.
10.1177/2050640618821800.
|
F
Fidon, L;
Ebner, M;
Garcia-Peraza-Herrera, LC;
Modat, M;
Ourselin, S;
Vercauteren, T;
(2019)
Incompressible Image Registration Using Divergence-Conforming B-Splines.
Medical Image Computing and Computer Assisted Intervention - MICCAI 2019
, 11765
pp. 438-446.
10.1007/978-3-030-32245-8_49.
|
Finnerty, E;
Ramasawmy, R;
O'Callaghan, J;
Connell, JJ;
Lythgoe, M;
Shmueli, K;
Thomas, DL;
(2019)
Noninvasive quantification of oxygen saturation in the portal and hepatic veins in healthy mice and those with colorectal liver metastases using QSM MRI.
Magnetic Resonance in Medicine
, 81
(4)
pp. 2666-2675.
10.1002/mrm.27571.
|
Firth, NC;
Primativo, S;
Marinescu, R-V;
Shakespeare, TJ;
Suarez-Gonzalez, A;
Lehmann, M;
Carton, A;
... Crutch, SJ; + view all
(2019)
Longitudinal neuroanatomical and cognitive progression of posterior cortical atrophy.
Brain
, 142
(7)
pp. 2082-2095.
10.1093/brain/awz136.
|
Fisher, CK;
Smith, AM;
Walsh, JR;
Simone, AJ;
Edgar, C;
Jack, CR;
Holtzman, D;
... Kubick, W; + view all
(2019)
Machine learning for comprehensive forecasting of Alzheimer's Disease progression.
Scientific Reports
, 9
, Article 13622. 10.1038/s41598-019-49656-2.
|
Flouri, D;
David, A;
Atkinson, D;
Pratt, R;
Mufti, N;
Sokolska, M;
Ourselin, S;
... Melbourne, A; + view all
(2019)
Improved Placental Parameter Estimation Using Data-Driven Bayesian Modelling.
In: Shen, D and Liu, T and Peters, TM and Staib, LH and Essert, C and Zhou, S and Yap, PT and Khan, A, (eds.)
Medical Image Computing and Computer Assisted Intervention: MICCAI 2019 22nd International Conference, Shenzhen, China, October 13–17, 2019, Proceedings, Part III.
(pp. pp. 609-616).
Springer: Cham, Switzerland.
|
Flouri, D;
Owen, D;
Aughwane, R;
Mufti, N;
Maksym, K;
Sokolska, M;
Kendall, G;
... Melbourne, A; + view all
(2019)
Improved fetal blood oxygenation and placental estimated measurements of diffusion-weighted MRI using data-driven Bayesian modeling.
Magnetic Resonance in Medicine
10.1002/mrm.28075.
(In press).
|
Flouri, D;
Pratt, R;
Sokolska, M;
Mufti, N;
Atkinson, D;
Kendall, G;
Bainbridge, A;
... Melbourne, A; + view all
(2019)
Model-Driven Registration for 3D Placental Diffusion-Weighted MRI.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition.
International Society for Magnetic Resonance in Medicine (ISMRM): Montreal, Canada.
|
G
Galgano, J;
Pantazatos, S;
Allen, K;
Yanagihara, T;
Hirsch, J;
(2019)
Functional connectivity of PAG with core limbic system and laryngeal cortico-motor structures during human phonation.
Brain Research
, 1707
pp. 184-189.
10.1016/j.brainres.2018.11.040.
|
Gallagher, J;
Ashley, P;
Petrie, A;
Needleman, I;
(2019)
Oral health-related behaviours reported by elite and professional athletes.
British Dental Journal
, 227
(4)
pp. 276-280.
10.1038/s41415-019-0617-8.
|
Garcia-Souto, MDP;
(2019)
Is It Safe To Use Peer Assessment Of Individual Contribution Level When Assessing Group Work?
In:
EDULEARN19 Proceedings.
(pp. pp. 7614-7622).
IATED: Palma, Spain.
|
Garcia-Souto, MDP;
(2019)
Making assessment of group work fairer and more insightful for students and time-efficient for staff with the new IPAC software.
In:
INTED2019 Proceedings.
(pp. pp. 8636-8641).
IATED: Valencia, Spain.
|
Gehrung, M;
Bohndiek, SE;
Brunker, J;
(2019)
Development of a blood oxygenation phantom for photoacoustic tomography combined with online pO2 detection and flow spectrometry.
Journal of Biomedical Optics
, 24
(12)
, Article 121908. 10.1117/1.JBO.24.12.121908.
|
George, J;
Giannoni, L;
Meng, LJ;
(2019)
Energy-modulated x-ray fluorescence and luminescence emissions from therapeutic nanoparticles.
Physics in Medicine and Biology
, 64
(3)
, Article 035020. 10.1088/1361-6560/aaeec3.
|
Ghavami, N;
Hu, Y;
Gibson, E;
Bonmati, E;
Emberton, M;
Moore, CM;
Barratt, DC;
(2019)
Automatic segmentation of prostate MRI using convolutional neural networks: Investigating the impact of network architecture on the accuracy of volume measurement and MRI-ultrasound registration.
Medical Image Analysis
, 58
, Article 101558. 10.1016/j.media.2019.101558.
|
Giannoni, L;
Lange, F;
Tachtsidis, I;
(2019)
A near-infrared hyperspectral imaging system for quantitative monitoring of hemodynamics and metabolism on the exposed cortex of mice.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Gilbert, R;
Peto, T;
Lengyel, I;
Emri, E;
(2019)
Zinc Nutrition and Inflammation in the Aging Retina.
Molecular Nutrition & Food Research
, 63
(15)
, Article 1801049. 10.1002/mnfr.201801049.
|
Gollifer, R;
Menys, A;
Zarate-Lopez, N;
Chatoor, D;
Emmanuel, A;
Taylor, S;
Atkinson, D;
(2019)
MRI assessed dysmotility and texture analysis in the terminal ileum and small bowel: A pilot study comparison between Irritable Bowel Syndrome (IBS) patients with bloating and healthy controls.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition.
International Society for Magnetic Resonance in Medicine (ISMRM): Montréal, Canada.
|
Gollifer, RM;
Menys, A;
Plumb, A;
Mengoudi, K;
Puylaert, CAJ;
Tielbeek, JAW;
Ponsioen, CY;
... Atkinson, D; + view all
(2019)
Automated versus subjective assessment of spatial and temporal MRI small bowel motility in Crohn's disease.
Clinical Radiology
, 74
(10)
814.e9-814.e19.
10.1016/j.crad.2019.06.016.
|
Goodkin, O;
Pemberton, H;
Vos, SB;
Prados, F;
Sudre, CH;
Moggridge, J;
Cardoso, MJ;
... Barkhof, F; + view all
(2019)
The quantitative neuroradiology initiative framework: application to dementia.
The British Institute of Radiology
, 92
(1101)
, Article 20190365. 10.1259/bjr.20190365.
|
Grammenos, R;
Garcia Souto, M;
Chester, I;
Albelda Gimeno, L;
(2019)
Peer assessment of individual contribution in group work: a student perspective.
In:
Proceedings of the SEFI 47th Annual Conference. Varietas delectat... Complexity is the new morality.
(pp. pp. 1594-1606).
European Society for Engineering Education (SEFI)
|
Gros, C;
De Leener, B;
Badji, A;
Maranzano, J;
Eden, D;
Dupont, SM;
Talbott, J;
... Cohen-Adad, J; + view all
(2019)
Automatic segmentation of the spinal cord and intramedullary multiple sclerosis lesions with convolutional neural networks.
Neuroimage
, 184
pp. 901-915.
10.1016/j.neuroimage.2018.09.081.
|
Guney, G;
Uluc, N;
Demirkiran, A;
Aytac-Kipergil, E;
Unlu, MB;
Birgul, O;
(2019)
Comparison of noise reduction methods in photoacoustic microscopy.
Computers in Biology and Medicine
, 109
pp. 333-341.
10.1016/j.compbiomed.2019.04.035.
|
Gupta, P;
Totti, S;
Pérez-Mancera, PA;
Dyke, E;
Nisbet, A;
Schettino, G;
Webb, R;
(2019)
Chemoradiotherapy screening in a novel biomimetic polymer based pancreatic cancer model.
RSC Advances
, 9
(71)
pp. 41649-41663.
10.1039/c9ra09123h.
|
Gutierrez, A;
Rompokos, V;
Li, K;
Gillies, C;
D'Souza, D;
Solda, F;
Fersht, N;
... Underwood, T; + view all
(2019)
The impact of proton LET/RBE modeling and robustness analysis on base-of-skull and pediatric craniopharyngioma proton plans relative to VMAT.
Acta Oncologica
10.1080/0284186X.2019.1653496.
(In press).
|
H
Haddow, L;
Sudre, CH;
Sokolska, M;
Gilson, RC;
Williams, I;
Golay, X;
Ourselin, S;
... Jäger, R; + view all
(2019)
Magnetic resonance imaging of cerebral small vessel disease in men living with HIV and HIV negative men aged 50 and above.
AIDS Research and Human Retroviruses
, 35
(5)
pp. 453-460.
10.1089/AID.2018.0249.
|
Hamid, S;
Donaldson, IA;
Hu, Y;
Rodell, R;
Villarini, B;
Bonmati, E;
Tranter, P;
... Ahmed, HU; + view all
(2019)
The SmartTarget Biopsy Trial: A Prospective, Within-person Randomised, Blinded Trial Comparing the Accuracy of Visual-registration and Magnetic Resonance Imaging/Ultrasound Image-fusion Targeted Biopsies for Prostate Cancer Risk Stratification.
European Urology
, 75
(5)
pp. 733-740.
10.1016/j.eururo.2018.08.007.
|
Hannan, Sana;
(2019)
Imaging fast neural activity in the brain during epilepsy with electrical impedance tomography.
Doctoral thesis (Ph.D), UCL (University College London).
|
Harrison, IF;
Whitaker, R;
Bertelli, PM;
O'Callaghan, JM;
Csincsik, L;
Bocchetta, M;
Ma, D;
... Lengyel, I; + view all
(2019)
Optic nerve thinning and neurosensory retinal degeneration in the rTg4510 mouse model of frontotemporal dementia.
Acta Neuropathologica Communications
, 7
, Article 4. 10.1186/s40478-018-0654-6.
|
Havariyoun, G;
Vittoria, FA;
Hagen, CK;
Basta, D;
Kallon, GK;
Endrizzi, M;
Massimi, L;
... Olivo, A; + view all
(2019)
A compact system for intraoperative specimen imaging based on edge illumination X-ray phase contrast.
Physics in Medicine and Biology
, 64
(23)
, Article 235005. 10.1088/1361-6560/ab4912.
|
Hobson, NJ;
Weng, X;
Siow, B;
Veiga, C;
Ashford, M;
Thanh, NT;
Schätzlein, AG;
(2019)
Clustering superparamagnetic iron oxide nanoparticles produces organ-targeted high-contrast magnetic resonance images.
Nanomedicine
, 14
(9)
pp. 1135-1152.
10.2217/nnm-2018-0370.
|
Hochuli, R;
An, L;
Beard, PC;
Cox, BT;
(2019)
Estimating blood oxygenation from photoacoustic images: can a simple linear spectroscopic inversion ever work?
Journal of Biomedical Optics
, 24
(12)
, Article 121914. 10.1117/1.JBO.24.12.121914.
|
Holyoake, DLP;
Partridge, M;
Hawkins, MA;
(2019)
Systematic review and meta-analysis of small bowel dose-volume and acute toxicity in conventionally-fractionated rectal cancer radiotherapy.
Radiotherapy and Oncology
, 138
pp. 38-44.
10.1016/j.radonc.2019.05.001.
|
Hope, J;
Aristovich, K;
Chapman, C;
Vanholsbeeck, F;
McDaid, A;
(2019)
Optimal frequency range for electrical impedance tomography of neural activity in peripheral nerve.
Presented at: 9th International IEEE EMBS Conference on Neural Engineering, San Francisco, CA, USA.
|
Hope, J;
Aristovich, KY;
Chapman, CAR;
Volschenk, A;
Vanholsbeeck, F;
McDaid, A;
(2019)
Extracting impedance changes from a frequency multiplexed signal during neural activity in sciatic nerve of rat: preliminary study in-vitro.
Physiological Measurement
, 40
(3)
, Article 034006. 10.1088/1361-6579/ab0c24.
|
Hu, Y;
Gibson, E;
Barratt, DC;
Emberton, M;
Noble, JA;
Vercauteren, T;
(2019)
Conditional Segmentation in Lieu of Image Registration.
In:
Proceedings of the nternational Conference on Medical Image Computing and Computer-Assisted Intervention MICCAI 2019.
(pp. pp. 401-409).
Springer: Shenzhen, China.
|
Huynh, N;
Lucka, F;
Zhang, E;
Betcke, M;
Arridge, SR;
Beard, PC;
Cox, BT;
(2019)
Single-pixel camera photoacoustic tomography.
Journal of Biomedical Optics
, 24
(12)
pp. 1-6.
10.1117/1.JBO.24.12.121907.
|
I
Irzan, H;
O'Reilly, H;
Ourselin, S;
Marlow, N;
Melbourne, A;
(2019)
A Framework For Memory Performance Prediction From Brain Volume In Preterm-Born Adolescents.
In:
2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019).
(pp. pp. 400-403).
IEEE: Venice, Italy.
|
J
Jacob, J;
Bartholmai, BJ;
Van Moorsel, CHM;
Rajagopalan, S;
Devaraj, A;
Van Es, HW;
Moua, T;
... Wells, AU; + view all
(2019)
Longitudinal prediction of outcome in idiopathic pulmonary fibrosis using automated CT analysis.
[Letter].
European Respiratory Journal
, 54
(3)
, Article 1802341. 10.1183/13993003.02341-2018.
|
Jacob, J;
Owens, C;
Brody, AS;
Semple, T;
Watson, T;
Calder, A;
Garcia-Pena, P;
... Bush, A; + view all
(2019)
Evaluation of Inter-Observer Variation for CT Identification of Childhood Interstitial Lung Disease.
[Letter].
American Journal of Respiratory and Critical Care Medicine
, 5
(3)
, Article 00100-2019. 10.1183/23120541.00100-2019.
|
Jager, KD;
Mentink, M;
Lancashire, H;
Al-Ajam, Y;
Taylor, S;
Vanhoestenberghe, A;
(2019)
Characterisation of a multi-channel multiplexed EMG recording system: towards realising variable electrode configurations.
In:
2019 IEEE Biomedical Circuits and Systems Conference (BioCAS).
IEEE: Nara, Japan.
|
Janus, J;
Kanber, B;
Mahbuba, W;
Beynon, C;
Ramnarine, KV;
Lambert, DG;
Samani, NJ;
... Kelly, ME; + view all
(2019)
A Preclinical Ultrasound Method for the Assessment of Vascular Disease Progression in Murine Models.
Ultrasound
, 27
(2)
pp. 85-93.
10.1177/1742271X18793919.
|
Javaherian, A;
Holman, S;
(2019)
Direct quantitative photoacoustic tomography for realistic acoustic media.
Inverse Problems
, 35
(8)
, Article 084004. 10.1088/1361-6420/ab091e.
|
Johnson, SP;
Ogunlade, O;
Lythgoe, MF;
Beard, P;
Pedley, RB;
(2019)
Longitudinal Photoacoustic Imaging of the Pharmacodynamic Effect of Vascular Targeted Therapy on Tumors.
Clinical Cancer Research
, 25
(24)
pp. 7436-7447.
10.1158/1078-0432.CCR-19-0360.
|
Johnston, EW;
Bonet-Carne, E;
Ferizi, U;
Yvernault, B;
Pye, H;
Patel, D;
Clemente, J;
... Punwani, S; + view all
(2019)
VERDICT MRI for Prostate Cancer: Intracellular Volume Fraction versus Apparent Diffusion Coefficient.
Radiology
, 291
(2)
pp. 391-397.
10.1148/radiol.2019181749.
|
Johnstone, R;
Atkinson, D;
Chouhan, M;
Sharma, R;
McClelland, J;
(2019)
Free-breathing MRI of the upper abdomen assisted by motion modelling.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition.
International Society for Magnetic Resonance in Medicine (ISMRM): Montréal, Canada.
|
Johnstone, RI;
Guerrero-Urbano, T;
Michaelidou, A;
Greener, T;
Miles, E;
Eaton, D;
Thomas, C;
(2019)
Guidance on the use of MRI for treatment planning in radiotherapy clinical trials.
British Journal of Radiology
, 92
, Article 20190161. 10.1259/bjr.20190161.
|
Jonasson, C;
Schaller, V;
Zeng, L;
Olsson, E;
Frandsen, C;
Castro, A;
Nilsson, L;
... Johansson, C; + view all
(2019)
Modelling the effect of different core sizes and magnetic interactions inside magnetic nanoparticles on hyperthermia performance.
Journal Of Magnetism And Magnetic Materials
, 477
pp. 198-202.
10.1016/j.jmmm.2018.09.117.
|
Jones, C;
Christens-Barry, WA;
Terras, M;
Toth, MB;
Gibson, A;
(2019)
Affine registration of multispectral images of historical documents for optimized feature recovery.
Digital Scholarship in the Humanities
10.1093/llc/fqz054.
(In press).
|
K
Kanber, B;
Nachev, P;
Barkhof, F;
Calvi, A;
Cardoso, M;
Cortese, R;
Prados Carrasco, F;
... Ciccarelli, O; + view all
(2019)
High-dimensional detection of imaging response to treatment in multiple sclerosis.
npj Digital Medicine
, 2
, Article 49. 10.1038/s41746-019-0127-8.
|
Karsa, A;
Goodburn, R;
Shmueli, K;
(2019)
SEGUE Unwraps MRI Phase Images Acquired in Mouse Brains at 9.4 Tesla Faster than PRELUDE.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition.
International Society for Magnetic Resonance in Medicine (ISMRM): Montréal, Canada.
|
Karsa, A;
Punwani, S;
Shmueli, K;
(2019)
The effect of low resolution and coverage on the accuracy of susceptibility mapping.
Magnetic Resonance in Medicine
, 81
(3)
pp. 1833-1848.
10.1002/mrm.27542.
|
Karsa, A;
Punwani, S;
Shmueli, K;
(2019)
High Repeatability of Quantitative Susceptibility Mapping (QSM) in the Head and Neck With a View to Detecting Hypoxic Cancer Sites.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition.
International Society for Magnetic Resonance in Medicine (ISMRM): Montréal, Canada.
|
Karsa, A;
Punwani, S;
Shmueli, K;
(2019)
High Repeatability of Quantitative Susceptibility Mapping (QSM) in the Head and Neck With a View to Detecting Hypoxic Cancer Sites.
Presented at: 5th International Workshop on MRI Phase Contrast and Quantitative Susceptibility Mapping, Seoul, Seoul, Korea.
|
Karsa, A;
Shmueli, K;
(2019)
Comparison of Two Truncation-based K-space Methods for Susceptibility Calculation: TKD_{Shmueli} and TKD_{Wharton}.
Presented at: 5th International Workshop on MRI Phase Contrast and Quantitative Susceptibility Mapping, Seoul, Seoul, Korea.
|
Katus, L;
Hayes, N;
Mason, L;
Blasi, A;
McCann, S;
Darboe, M;
de Haan, M;
... Elwell, C; + view all
(2019)
Implementing neuroimaging and eye tracking methods to assess neurocognitive development of young infants in low- and middle-income countries [version 2; peer review: 2 approved].
Gates Open Research
, 3
, Article 1113. 10.12688/gatesopenres.12951.2.
|
Katus, L;
Hayes, NJ;
Mason, L;
Blasi, A;
McCann, S;
Darboe, MK;
de Haan, M;
... Elwell, CE; + view all
(2019)
Implementing neuroimaging and eye tracking methods to assess neurocognitive development of young infants in low- and middle-income countries.
Gates Open Research
, 3
, Article 1113. 10.12688/gatesopenres.12951.2.
|
Kaura, A;
Tan, M;
Nip, L;
Whitcroft, KL;
Mehta, N;
Hannan, SA;
Leung, TS;
... Andrews, P; + view all
(2019)
A North London Pilot Survey to Assess the Need for a Medical Device in Diagnosing Chronic Rhinosinusitis in Primary Care.
Open Journal of Otolaryngology
, 2
(2)
pp. 24-29.
|
Kaynezhad, P;
Mitra, S;
Bale, G;
Bauer, C;
Lingam, I;
Meehan, C;
Avdic-Belltheus, A;
... Tachtsidis, I; + view all
(2019)
Quantification of the severity of hypoxic-ischemic brain injury in a neonatal preclinical model using measurements of cytochrome-c-oxidase from a miniature broadband-near-infrared spectroscopy system.
Neurophotonics
, 6
(4)
, Article 045009. 10.1117/1.NPh.6.4.045009.
|
Kelleter, L;
Zhen-Hong Tham, B;
Saakyan, R;
Griffiths, J;
Amos, R;
Jolly, S;
Gibson, A;
(2019)
Technical note: Simulation of dose build-up in proton pencil beams.
Medical Physics
, 46
(8)
pp. 3734-3738.
10.1002/mp.13660.
|
Khan, S;
Zollitsch, CW;
Arroo, DM;
Cheng, H;
Verzhbitskiy, I;
Sud, A;
Feng, YP;
... Kurebayashi, H; + view all
(2019)
Spin dynamics study in layered van der Waals single-crystal Cr2Ge2Te6.
Physical Review B
, 100
, Article 134437. 10.1103/PhysRevB.100.134437.
|
Khodadad, D;
Nordebo, S;
Seifnaraghi, N;
Yerworth, R;
Waldmann, AD;
Mueller, B;
Frerichs, I;
... Bayford, R; + view all
(2019)
The Value of Phase Angle in Electrical Impedance Tomography Breath Detection.
In: Chew, WC and He, S, (eds.)
2018 Progress in Electromagnetics Research Symposium (PIERS-Toyama).
(pp. pp. 1040-1043).
IEEE: Toyama, Japan.
|
Khong, J;
Speller, R;
Moss, R;
Dorkings, S;
Moss, K;
(2019)
Rapid prototyping of cost efficient X-ray collimators.
Manufacturing Letters
, 20
pp. 49-53.
10.1016/j.mfglet.2019.05.001.
|
Kissane, RWP;
Wright, O;
Al'Joboori, YD;
Marczak, P;
Ichiyama, RM;
Egginton, S;
(2019)
Effects of treadmill training on microvascular remodeling in the rat after spinal cord injury.
Muscle & Nerve
, 59
(3)
pp. 370-379.
10.1002/mus.26379.
|
Klaser, K;
Varsavsky, T;
Markiewicz, P;
Atkinson, D;
Thielemans, K;
Hutton, B;
Cardoso, M;
(2019)
Improved MR to CT synthesis for PET/MR attenuation correction using Imitation Learning.
In: Burgos, N and Gooya, A and Svoboda, D, (eds.)
Simulation and Synthesis in Medical Imaging. SASHIMI 2019. Lecture Notes in Computer Science, vol 11827.
Springer: Cham.
|
Kovácsová, Z;
Bale, G;
Veesa, JD;
Dehghani, H;
Tachtsidis, I;
(2019)
A broadband multi-distance approach to measure tissue oxygen saturation with continuous wave near-infrared spectroscopy.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Koychev, I;
Lawson, J;
Chessell, T;
Mackay, C;
Gunn, R;
Sahakian, B;
Rowe, JB;
... Lovestone, S; + view all
(2019)
Deep and Frequent Phenotyping study protocol: an observational study in prodromal Alzheimer's disease.
BMJ Open
, 9
(3)
, Article e024498. 10.1136/bmjopen-2018-024498.
|
Kuijf, HJ;
Biesbroek, JM;
de Bresser, J;
Heinen, R;
Andermatt, S;
Bento, M;
Berseth, M;
... Biessels, GJ; + view all
(2019)
Standardized Assessment of Automatic Segmentation of White Matter Hyperintensities; Results of the WMH Segmentation Challenge.
IEEE Transactions on Medical Imaging
, 38
(11)
pp. 2556-2568.
10.1109/TMI.2019.2905770.
|
L
Lacher, Rene Michel;
(2019)
3D breast surface reconstructions from consumer-grade RGB-D cameras.
Doctoral thesis (Ph.D), UCL (University College London).
|
Lacher, RM;
Vasconcelos, F;
Williams, N;
Rindermann, G;
Hipwell, J;
Hawkes, D;
Stoyanov, D;
(2019)
Nonrigid reconstruction of 3D breast surfaces with a low-cost RGBD camera for surgical planning and aesthetic evaluation.
Medical Image Analysis
, 53
pp. 11-25.
10.1016/j.media.2019.01.003.
|
Lancashire, H;
Ajam, Y;
Dowling, R;
Pendegrass, C;
Blunn, G;
(2019)
Hard-wired Epimysial Recordings from Normal and Reinnervated Muscle using a Bone-Anchored Device.
Plastic and Reconstructive Surgery - Global Open
, 7
(9)
, Article e2391. 10.1097/GOX.0000000000002391.
|
Lancashire, HT;
Jiang, D;
Demosthenous, A;
Donaldson, N;
(2019)
An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces.
IEEE Transactions on Biomedical Circuits and Systems
, 13
(2)
pp. 259-270.
10.1109/TBCAS.2019.2891284.
|
Lange, F;
Dunne, L;
Hale, L;
Tachtsidis, I;
(2019)
MAESTROS: A multi-wavelength time domain NIRS system to monitor changes in oxygenation and oxidation state of cytochrome-c-oxidase.
IEEE Journal of Selected Topics in Quantum Electronics
, 25
(1)
, Article 7100312. 10.1109/JSTQE.2018.2833205.
|
Lange, F;
Tachtsidis, I;
(2019)
Clinical Brain Monitoring with Time Domain NIRS: A Review and Future Perspectives.
[Review].
Applied Sciences
, 9
(8)
, Article 1612. 10.3390/app9081612.
|
Lange, F;
Tachtsidis, I;
(2019)
Short and mid-term reproducibility analysis of cerebral tissue saturation measured by time domain-NIRS.
In:
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Lanka, P;
Yang, L;
Orive-Miguel, D;
Veesa, JD;
Tagliabue, S;
Sudakou, A;
Samaei, S;
... Pifferi, A; + view all
(2019)
The BITMAP exercise: a multi-laboratory performance assessment campaign of diffuse optical instrumentation.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Leijsen, R;
Fuchs, P;
Brink, W;
Webb, A;
Remis, R;
(2019)
Developments in Electrical-Property Tomography Based on the Contrast-Source Inversion Method.
Journal of Imaging
, 5
(2)
, Article 25. 10.3390/jimaging5020025.
|
Leung, TS;
Outlaw, F;
MacDonald, LW;
Meek, J;
(2019)
Jaundice Eye Color Index (JECI): quantifying the yellowness of the sclera in jaundiced neonates with digital photography.
Biomedical Optics Express
, 10
(3)
pp. 1250-1256.
10.1364/BOE.10.001250.
|
Li, K;
Vakharia, VN;
Sparks, R;
Rodionov, R;
Vos, SB;
McEvoy, AW;
Miserocchi, A;
... Duncan, JS; + view all
(2019)
Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts.
Epilepsia
10.1111/epi.16294.
(In press).
|
Li, Q;
Lin, J;
Clancy, NT;
Elson, DS;
(2019)
Estimation of tissue oxygen saturation from RGB images and sparse hyperspectral signals based on conditional generative adversarial network.
International Journal of Computer Assisted Radiology and Surgery
, 14
(6)
pp. 987-995.
10.1007/s11548-019-01940-2.
|
Lindenroth, L;
Housden, RJ;
Wang, S;
Back, J;
Rhode, K;
Liu, H;
(2019)
Design and integration of a parallel, soft robotic end-effector for extracorporeal ultrasound.
IEEE Transactions on Biomedical Engineering
10.1109/TBME.2019.2957609.
(In press).
|
Lingam, I;
Meehan, C;
Avdic-Belltheus, A;
Martinello, K;
Hristova, M;
Kaynezhad, P;
Bauer, C;
... Robertson, NJ; + view all
(2019)
Short-term effects of early initiation of magnesium infusion combined with cooling after hypoxia-ischemia in term piglets.
Pediatric Research
, 86
pp. 699-708.
10.1038/s41390-019-0511-8.
|
Little, CD;
Poduval, RK;
Caulfield, R;
Noimark, S;
Colchester, RJ;
Loder, CD;
Tiwari, MK;
... Desjardins, AE; + view all
(2019)
Micron resolution, high-fidelity three-dimensional vascular optical imaging phantoms.
Journal of Biomedical Optics
, 24
(2)
, Article 020502. 10.1117/1.JBO.24.2.020502.
|
Lloyd-Fox, S;
Blasi, A;
McCann, S;
Rozhko, M;
Katus, L;
Mason, L;
Austin, T;
... BRIGHT project team; + view all
(2019)
Habituation and novelty detection fNIRS brain responses in 5- and 8-month-old infants: The Gambia and UK.
Developmental Science
, Article e12817. 10.1111/desc.12817.
(In press).
|
Lo, E;
Menezes, L;
Torii, R;
(2019)
On boundary conditions in computation of CT-based FFR: a study integrating pet perfusion images in CFD.
In:
Proceedings of the 6th International Conference on Computational and Mathematical Biomedical Engineering.
(pp. pp. 119-122).
Computational and Mathematical Biomedical Engineering (CMBE): Cardiff, UK.
|
Lo, EWC;
Menezes, LJ;
Torii, R;
(2019)
Impact of inflow boundary conditions on the calculation of CT-based FFR.
Fluids
, 4
(2)
, Article 60. 10.3390/fluids4020060.
|
Lorenzi, M;
Filippone, M;
Frisoni, GB;
Alexander, DC;
Ourselin, S;
Alzheimer's Disease Neuroimaging Initiative, .;
(2019)
Probabilistic disease progression modeling to characterize diagnostic uncertainty: Application to staging and prediction in Alzheimer's disease.
NeuroImage
, 190
pp. 56-68.
10.1016/j.neuroimage.2017.08.059.
|
Lourenço, A;
Bouchard, H;
Galer, S;
Royle, G;
Palmans, H;
(2019)
The influence of nuclear interactions on ionization chamber perturbation factors in proton beams: FLUKA simulations supported by a Fano test.
Medical Physics
, 46
(2)
pp. 885-891.
10.1002/mp.13281.
|
Lundell, H;
Nilsson, M;
Dyrby, TB;
Parker, GJM;
Cristinacce, PLH;
Zhou, F-L;
Topgaard, D;
(2019)
Multidimensional diffusion MRI with spectrally modulated gradients reveals unprecedented microstructural detail.
Scientific Reportsvolume
, 9
, Article 9026. 10.1038/s41598-019-45235-7.
|
M
Ma, D;
Holmes, HE;
Cardoso, MJ;
Modat, M;
Harrison, IF;
Powell, NM;
O'Callaghan, JM;
... Ourselin, S; + view all
(2019)
Study the Longitudinal in vivo and Cross-Sectional ex vivo Brain Volume Difference for Disease Progression and Treatment Effect on Mouse Model of Tauopathy Using Automated MRI Structural Parcellation.
Frontiers in Neuroscience
, 13
, Article 11. 10.3389/fnins.2019.00011.
|
Macdonald, CM;
Arridge, SR;
Munro, PRT;
(2019)
Solving the inverse problem in OCT using full-wave adjoint models.
In:
2019 IEEE Photonics Conference (IPC).
IEEE: San Antonio, TX, USA.
|
Macdonald, CM;
Munro, PRT;
(2019)
Synthesizing scanning-mode acquisition in full-wave modelling of OCT.
In:
Progress in Biomedical Optics and Imaging - Proceedings of SPIE.
SPIE: Munich, Germany.
|
Mackle, EC;
Maneas, E;
Little, C;
Carr, E;
Xia, W;
Nikitichev, D;
Rakhit, RD;
... Desjardins, AE; + view all
(2019)
Wall-less vascular poly(vinyl) alcohol gel ultrasound imaging phantoms using 3D printed vessels.
In: Liang, R and Hwang, J and Pfefer, TJ and Vargas, G, (eds.)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE.
SPIE
|
Manara, A;
Varelas, P;
Smith, M;
(2019)
Neurological determination of death in isolated brainstem lesions: A case report to highlight the issues involved.
Journal of the Intensive Care Society
10.1177/1751143719832169.
(In press).
|
Mancini, M;
Crampsie, S;
Thomas, DL;
Jaunmuktane, Z;
Holton, JL;
Iglesias, JE;
(2019)
Hierarchical Joint Registration of Tissue Blocks With Soft Shape Constraints For Large-Scale Histology of The Human Brain.
In:
2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019).
(pp. pp. 666-669).
IEEE: Venice, Italy.
|
Mancini, M;
Vos, S;
Vakharia, V;
O'Keeffe, A;
Trimmel, K;
Barkhof, F;
Dorfer, C;
... Ourselin, S; + view all
(2019)
Automated fiber tract reconstruction for surgery planning: Extensive validation in language-related white matter tracts.
NeuroImage: Clinical
, 23
, Article 101883. 10.1016/j.nicl.2019.101883.
|
Maneas, E;
Aughwane, R;
Huynh, N;
Xia, W;
Ansari, R;
Kuniyil Ajith Singh, M;
Hutchinson, JC;
... Desjardins, AE; + view all
(2019)
Photoacoustic imaging of the human placental vasculature.
Journal of Biophotonics
, Article e201900167. 10.1002/jbio.201900167.
(In press).
|
Maneas, Efthymios;
(2019)
Multimodal and multiscale imaging of the human placental vasculature.
Doctoral thesis (Ph.D), UCL (University College London).
|
Marques, DM;
Guggenheim, JA;
Ansari, R;
Zhang, EZ;
Beard, PC;
Munro, PRT;
(2019)
On the intuitive understanding of interrogating Fabry-Perot etalon with a focused beam.
In:
Photons Plus Ultrasound: Imaging and Sensing 2019.
(pp. 108780Q-108780Q).
SPIE
|
Marques, DM;
Guggenheim, JA;
Ansari, R;
Zhang, EZ;
Beard, PC;
Munro, PRT;
(2019)
Probing the optical readout characteristics of Fabry-Perot ultrasound sensors through realistic modelling.
In:
Proceedings of the Opto-Acoustic Methods and Applications in Biophotonics IV.
SPIE
|
Martin, E;
Treeby, B;
(2019)
Investigation of the repeatability and reproducibility of hydrophone measurements of medical ultrasound fields.
Journal of the Acoustical Society of America
, 145
(3)
pp. 1270-1282.
10.1121/1.5093306.
|
Martin-Sanchez, D;
Kovylina, M;
Ponce-Alcantara, S;
Garcia-Ruperez, J;
(2019)
Thermo-Optic Coefficient of Porous Silicon in the Infrared Region and Oxidation Process at Low Temperatures.
Journal of The Electrochemical Society
, 166
(6)
B355-B359.
10.1149/2.0341906jes.
|
Martin-Sanchez, D;
Ponce-Alcantara, S;
Garcia-Ruperez, J;
(2019)
Sensitivity Comparison of a Self-Standing Porous Silicon Membrane Under Flow-Through and Flow-Over Conditions.
IEEE Sensors Journal
, 19
(9)
pp. 3276-3281.
10.1109/JSEN.2019.2893885.
|
Martin-Sanchez, D;
Ponce-Alcantara, S;
Martinez-Perez, P;
Garcia-Ruperez, J;
(2019)
Macropore Formation and Pore Morphology Characterization of Heavily Doped p-Type Porous Silicon.
Journal of The Electrochemical Society
, 166
(2)
B9-B12.
10.1149/2.0051902jes.
|
Martinello, KA;
Meehan, C;
Avdic-Belltheus, A;
Lingam, I;
Ragab, S;
Hristova, M;
Tann, CJ;
... Robertson, NJ; + view all
(2019)
Acute LPS sensitization and continuous infusion exacerbates hypoxic brain injury in a piglet model of neonatal encephalopathy.
Scientific Reports
, 9
(1)
, Article 10184. 10.1038/s41598-019-46488-y.
|
Massimi, L;
Hagen, CK;
Endrizzi, M;
Munro, PRT;
Havariyoun, G;
Hawker, PMS;
Smit, B;
... Olivo, A; + view all
(2019)
Laboratory-based x-ray phase contrast CT technology for clinical intra-operative specimen imaging.
In:
Medical Imaging 2019: Physics of Medical Imaging.
SPIE: San Diego, California, United States.
|
Maughan Jones, Charlotte Joanna;
(2019)
Application of x-ray phase imaging in the estimation of tissue optical scattering.
Doctoral thesis (Ph.D), UCL (University College London).
|
McDermott, BJ;
Avery, J;
O'Halloran, M;
Aristovich, KY;
Porter, E;
(2019)
Bi-frequency symmetry difference electrical impedance tomography—a novel technique for perturbation detection in static scenes.
Physiological Measurement
, 40
(4)
, Article 044005. 10.1088/1361-6579/ab08ba.
|
Merle, BMJ;
Colijn, JM;
Cougnard-Grégoire, A;
de Koning-Backus, APM;
Delyfer, MN;
Kiefte-de Jong, JC;
Meester-Smoor, M;
... Vasiliev, V; + view all
(2019)
Mediterranean Diet and Incidence of Advanced Age-Related Macular Degeneration: The EYE-RISK Consortium.
Ophthalmology
, 126
(3)
pp. 381-390.
10.1016/j.ophtha.2018.08.006.
|
Meyfroidt, G;
Gunst, J;
Martin-Loeches, I;
Smith, M;
Robba, C;
Taccone, FS;
Citerio, G;
(2019)
Management of the brain-dead donor in the ICU: general and specific therapy to improve transplantable organ quality.
Intensive Care Medicin
, 45
(3)
pp. 343-353.
10.1007/s00134-019-05551-y.
|
Mihalik, A;
Brudfors, M;
Robu, M;
Ferreira, FS;
Lin, H;
Rau, A;
Wu, T;
... Oxtoby, NP; + view all
(2019)
ABCD Neurocognitive Prediction Challenge 2019: Predicting Individual Fluid Intelligence Scores from Structural MRI Using Probabilistic Segmentation and Kernel Ridge Regression.
In: Pohl, K and Thompson, W and Adeli, E and Linguraru, M, (eds.)
Adolescent Brain Cognitive Development Neurocognitive Prediction. ABCD-NP 2019. Lecture Notes in Computer Science.
(pp. pp. 133-142).
Springer: Cham.
|
Minhas, K;
Roebuck, DJ;
Barnacle, A;
De Coppi, P;
Sebire, N;
Patel, PA;
(2019)
Diagnostic yield and safety of ultrasound-guided bowel mass biopsies in children.
Pediatric Radiology
10.1007/s00247-019-04472-8.
(In press).
|
Mitsides, N;
Alsehli, FMS;
Mc Hough, D;
Shalamanova, L;
Wilkinson, F;
Alderdice, J;
Mitra, R;
... Mitra, S; + view all
(2019)
Salt and Water Retention Is Associated with Microinflammation and Endothelial Injury in Chronic Kidney Disease.
Nephron
, 143
(4)
pp. 234-242.
10.1159/000502011.
|
Moccia, M;
Prados Carrasco, F;
Filippi, M;
Rocca, M;
Valsasina, P;
Brownlee, W;
Zecca, C;
... for the MAGNIMS Study Group, .; + view all
(2019)
Longitudinal spinal cor atrophy in multiple sclerosis using the generalised boundary shift integral.
Annals of Neurology
, 86
(5)
pp. 704-713.
10.1002/ana.25571.
|
Modregger, P;
Meganck, J;
Hagen, CK;
Massimi, L;
Olivo, A;
Endrizzi, M;
(2019)
Improved iterative tomographic reconstruction for x-ray imaging with edge-illumination.
Physics in Medicine and Biology
10.1088/1361-6560/ab439d.
(In press).
|
Moriconi, S;
Rehwald, R;
Zuluaga, MA;
Jäger, HR;
Nachev, P;
Ourselin, S;
Cardoso, MJ;
(2019)
Towards Quantifying Neurovascular Resilience.
Lecture Notes in Computer Science
, 11794
pp. 149-157.
10.1007/978-3-030-33327-0_18.
|
Moriconi, S;
Zuluaga, MA;
Jager, HR;
Nachev, P;
Ourselin, S;
Cardoso, MJ;
(2019)
Inference of Cerebrovascular Topology with Geodesic Minimum Spanning Trees.
IEEE Transactions on Medical Imaging
, 38
(1)
pp. 225-239.
10.1109/TMI.2018.2860239.
|
Moss, RM;
Wilson, MD;
Morton, EJ;
Speller, RD;
(2019)
Hybrid Angular- and Energy-Dispersive X-ray Diffraction Computed Tomography.
In:
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).
IEEE: Sydney, Australia.
|
Munro, P;
(2019)
Rigorous multi-slice wave optical simulation of x-ray propagation in inhomogeneous space.
Journal of the Optical Society of America A
, 36
(7)
pp. 1197-1208.
10.1364/JOSAA.36.001197.
|
Murdoch, R;
Kawadler, J;
Kirkham, F;
Shmueli, K;
(2019)
MRI susceptibility mapping suggests elevated brain iron in sickle cell anaemia.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition. SMRT 28th Annual Meeting.
(pp. pp. 1-3).
International Society for Magnetic Resonance in Medicine (ISMRM)
|
Murdoch, R;
Stotesbury, H;
Kawadler, J;
Kirkham, F;
Shmueli, K;
(2019)
MRI susceptibility mapping shows decreased venous oxygen saturation in sickle cell anaemia.
In:
Proceedings of the ISMRM 27th Annual Meeting & Exhibition. SMRT 28th Annual Meeting.
(pp. pp. 1-3).
International Society for Magnetic Resonance in Medicine (ISMRM)
|
N
Neary-Zajiczek, L;
Essmann, C;
Clancy, N;
Haider, A;
Miranda, E;
Shaw, M;
Gander, A;
... Stoyanov, D; + view all
(2019)
Whole-sample mapping of cancerous and benign tissue properties.
In:
Medical Image Computing and Computer Assisted Intervention – MICCAI 2019.
(pp. pp. 760-768).
Springer Nature: Cham, Switzerland.
|
Nikitichev, DI;
Murawski, K;
Harris, G;
Perkins, G;
Mosse, S;
Maneas, E;
Xia, W;
... Hebden, J; + view all
(2019)
3D printed kidney phantoms for an LED-based photoacoustic and ultrasound imaging system.
In: Kress, Bernard, (ed.)
Proceedings Volume 10878, Photons Plus Ultrasound: Imaging and Sensing 2019.
SPIE: Bellingham, WA, USA.
|
Nixon, M;
Outlaw, F;
MacDonald, LW;
Leung, TS;
(2019)
The importance of a device specific calibration for smartphone colorimetry.
In:
27th Color and Imaging Conference Final Program and Proceedings.
(pp. pp. 49-54).
Society for Imaging Science and Technology: Paris, France.
|
O
Ogunlade, O;
Ho, J;
Kalber, T;
Hynds, R;
Zhang, E;
Janes, SM;
Birchall, M;
... Beard, P; + view all
(2019)
Monitoring neovascularization and integration of decellularized human scaffolds using photoacoustic imaging.
Photoacoustics
, 13
pp. 76-84.
10.1016/j.pacs.2019.01.001.
(In press).
|
Olivo, A;
Vittoria, FA;
Modregger, P;
Kallon, GK;
Massimi, L;
Jiang, J;
Savvidis, S;
... Endrizzi, M; + view all
(2019)
Flexible solutions for lab-based phase contrast and dark field CT and micro-CT.
In:
iCT 2019 Session: New Methods & Optimization.
(pp. pp. 23652-1).
NDT.net: Padova, Italy.
|
Orbes-Arteaga, M;
Varsavsky, T;
Sudre, CH;
Eaton-Rosen, Z;
Haddow, LJ;
Sørensen, L;
Nielsen, M;
... Cardoso, MJ; + view all
(2019)
Multi-domain adaptation in brain MRI through paired consistency and adversarial learning.
In:
Domain Adaptation and Representation Transfer and Medical Image Learning with Less Labels and Imperfect Data.
(pp. pp. 54-62).
Springer: Cham, Switzerland.
|
Orive-Miguel, D;
Lanka, P;
Yang, L;
Tagliabue, S;
Sudakou, A;
Samaei, S;
Veesa, JD;
... Pifferi, A; + view all
(2019)
The BitMap dataset: an open dataset on performance assessment of diffuse optics instruments.
In: Dehghani, H and Wabnitz, H, (eds.)
Diffuse Optical Spectroscopy and Imaging VII.
SPIE: Munich, Germany.
|
Outlaw, F;
Nixon, M;
Brako, NO;
MacDonald, LW;
Meek, J;
Enweronu-Laryea, C;
Leung, TS;
(2019)
Smartphone colorimetry using ambient subtraction: Application to neonatal jaundice screening in Ghana.
In:
UbiComp/ISWC 2019- - Adjunct Proceedings of the 2019 ACM International Joint Conference on Pervasive and Ubiquitous Computing and Proceedings of the 2019 ACM International Symposium on Wearable Computers.
(pp. pp. 172-175).
ACM: London, UK.
|
Oxtoby, NP;
Ferreira, FS;
Mihalik, A;
Wu, T;
Brudfors, M;
Lin, H;
Rau, A;
... Mourão-Miranda, J; + view all
(2019)
ABCD Neurocognitive Prediction Challenge 2019: Predicting Individual Residual Fluid Intelligence Scores from Cortical Grey Matter Morphology.
In: Pohl, K and Thompson, W and Adeli, E and Linguraru, M, (eds.)
Adolescent Brain Cognitive Development Neurocognitive Prediction. ABCD-NP 2019. Lecture Notes in Computer Science, vol 11791.
(pp. pp. 114-123).
Springer: Cham.
|
P
Pagliazzi, M;
Vidal-Rosas, EE;
Sekar, SKV;
Di Sieno, L;
Colombo, L;
Contini, D;
Torricelli, A;
... Durduran, T; + view all
(2019)
In vivo Time Domain Speckle Contrast Optical Spectroscopy.
In: Dehghani, H and Wabnitz, H, (eds.)
(Proceedings) Conference on Diffuse Optical Spectroscopy and Imaging VII held at European Conferences on Biomedical Optics.
SPIE: Munich, Germany.
|
Papadimitriou, K;
Hebden, J;
Arridge, S;
Powell, S;
(2019)
A dual-wavelength spread spectrum-based spectroscopic system For time-domain near-infrared diffuse optical imaging.
In: Fantini, S and Tromberg, BJ and Sevick-Muraca, E and Taroni, P, (eds.)
Proceedings of SPIE. Optical Tomography and Spectroscopy of Tissue XIII.
SPIE: San Francisco (CA), USA.
|
Partridge, TA;
Ahmed, M;
Choudhary, SB;
van der Walle, CF;
Patel, SM;
Bishop, SM;
Mantle, MD;
(2019)
Application of Magnetic Resonance to Assess Lyophilized Drug Product Reconstitution.
Pharmaceutical Research
, 36
(5)
p. 71.
10.1007/s11095-019-2591-x.
|
Pasco, G;
Davies, K;
Ribeiro, H;
Tucker, L;
Allison, C;
Baron-Cohen, S;
Johnson, MH;
... Salomone, E; + view all
(2019)
Comparison of Parent Questionnaires, Examiner-Led Assessment and Parents’ Concerns at 14 Months of Age as Indicators of Later Diagnosis of Autism.
Journal of Autism and Developmental Disorders
10.1007/s10803-019-04335-z.
(In press).
|
Patel, PA;
Gibson, C;
Minhas, KS;
Stuart, S;
De Coppi, P;
Roebuck, DJ;
(2019)
Pancreatic pseudocyst drainage in children by image-guided cystogastrostomy and stent insertion.
Pediatric Radiology
10.1007/s00247-019-04471-9.
(In press).
|
Patel, PA;
Minhas, K;
Ang, J;
Stuart, S;
De Coppi, P;
Gnannt, R;
(2019)
Non-vascular interventional radiology in the paediatric alimentary tract.
European Journal of Radiology
, 112
pp. 72-81.
10.1016/j.ejrad.2018.12.012.
|
Patrick, PS;
Bogart, LK;
Macdonald, TJ;
Southern, P;
Powell, MJ;
Zaw-Thin, M;
Voelcker, NH;
... Bear, JC; + view all
(2019)
Surface radio-mineralisation mediates chelate-free radiolabelling of iron oxide nanoparticles.
Chemical Science
, 10
(9)
pp. 2592-2597.
10.1039/c8sc04895a.
|
Perdue, KL;
Jensen, SKG;
Kumar, S;
Richards, JE;
Kakon, SH;
Haque, R;
Petri, WA;
... Nelson, CA; + view all
(2019)
Using functional near-infrared spectroscopy to assess social information processing in poor urban Bangladeshi infants and toddlers.
Developmental Science
, Article e12839. 10.1111/desc.12839.
(In press).
|
Pfeiffer, M;
Funke, I;
Robu, MR;
Bodenstedt, S;
Strenger, L;
Engelhardt, S;
Roß, T;
... Speidel, S; + view all
(2019)
Generating large labeled data sets for laparoscopic image processing tasks using unpaired image-to-image translation.
In:
Proceedings of the Generating large labeled data sets for laparoscopic image processing tasks using unpaired image-to-image translation.
(pp. pp. 119-127).
Springer: Shenzhen, China.
|
Phillips, I;
Ezhil, V;
Hussein, M;
South, C;
Nisbet, A;
Alobaidli, S;
Prakash, V;
... Evans, P; + view all
(2019)
Textural analysis and lung function study: Predicting lung fitness for radiotherapy from a CT scan.
BJR | Open
, 1
(1)
, Article 20180001. 10.1259/bjro.20180001.
|
Pichat, Jonas;
(2019)
Registration of histology and magnetic resonance imaging of the brain.
Doctoral thesis (Ph.D), UCL (University College London).
|
Pinti, P;
Scholkmann, F;
Hamilton, A;
Burgess, P;
Tachtsidis, I;
(2019)
Current Status and Issues Regarding Pre-processing of fNIRS Neuroimaging Data: An Investigation of Diverse Signal Filtering Methods Within a General Linear Model Framework.
Frontiers in Human Neuroscience
, 12
, Article 505. 10.3389/fnhum.2018.00505.
|
Pohle, U;
Baumann, E;
Pulwer, S;
Villringer, C;
Zhang, E;
Gerhardt, H;
Laufer, J;
(2019)
Development of a backward-mode photoacoustic microscope using a Fabry-Perot sensor.
In: Oraevsky, AA and Wang, LV, (eds.)
Photons Plus Ultrasound: Imaging and Sensing 2019;.
SPIE: San Francisco, CA, USA.
|
Pombo, G;
Gray, R;
Varsavsky, T;
Ashburner, J;
Nachev, P;
(2019)
Bayesian Volumetric Autoregressive generative models for better semisupervised learning.
In:
Proceedings of the International Conference on Medical Image Computing and Computer-Assisted Intervention MICCAI 201.
(pp. pp. 429-437).
Springer
|
Ponce-Alcantara, S;
Martin-Sanchez, D;
Kovylina, M;
Perez-Marquez, A;
Maudes, J;
Murillo, N;
Garcia-Ruperez, J;
(2019)
Dual Refractive Index and Viscosity Sensing Using Polymeric Nanofibers Optical Structures.
IEEE Sensors Journal
, 19
(24)
pp. 11850-11857.
10.1109/jsen.2019.2938832.
|
Pote, I;
Wang, S;
Sethna, V;
Blasi, A;
Daly, E;
Kuklisova-Murgasova, M;
Lloyd-Fox, S;
... BASIS Team; + view all
(2019)
Familial risk of autism alters subcortical and cerebellar brain anatomy in infants and predicts the emergence of repetitive behaviors in early childhood.
Autism Research
10.1002/aur.2083.
(In press).
|
Powell, E;
Prados, F;
Chard, D;
Toosy, A;
Clayden, JD;
Wheeler-Kingshott, CGAM;
(2019)
Edge Weights and Network Properties in Multiple Sclerosis.
In: Frangi, Alejandro and Alberola-Lopez, Carlos, (eds.)
Proceedings of the 21st International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2018).
(pp. pp. 281-291).
Springer: Cham, Switzerland.
|
Powell, S;
Cox, BT;
Arridge, SR;
(2019)
A pseudospectral method for solution of the radiative transport equation.
Journal of Computational Physics
, 384
pp. 376-382.
10.1016/j.jcp.2019.01.024.
|
Price, Tony;
Allport, Phil;
Green, Stuart;
Shaikh, Saad;
Radogna, Raffaella;
Walker, Daniel;
Kelleter, Laurent;
... Jolly, Simon; + view all
(2019)
Proof of principle detector for fast patient quality assurance.
Presented at: 58th Annual Conference of the Particle Therapy Co-operative Group {PTCOG58), Manchester, UK.
|
Pryor, R;
Norvaisas, P;
Marinos, G;
Best, L;
Thingholm, LB;
Quintaneiro, LM;
De Haes, W;
... Cabreiro, F; + view all
(2019)
Host-Microbe-Drug-Nutrient Screen Identifies Bacterial Effectors of Metformin Therapy.
Cell
, 178
(6)
1299-1312.e29.
10.1016/j.cell.2019.08.003.
|
Q
Quan, K;
Tanno, R;
Duong, M;
Nair, A;
Shipley, R;
Jones, M;
Brereton, C;
... Jacob, J; + view all
(2019)
Modelling Airway Geometry as Stock Market Data Using Bayesian Changepoint Detection.
In: Suk, H and Liu, M and Yan, P and Lian, C, (eds.)
MLMI 2019: Machine Learning in Medical Imaging.
(pp. pp. 345-354).
Springer: Shenzhen, China.
|
Quan, K;
Tanno, R;
Shipley, RJ;
Brown, JS;
Jacob, J;
Hurst, JR;
Hawkes, DJ;
(2019)
Reproducibility of an airway tapering measurement in computed tomography with application to bronchiectasis.
Journal of Medical Imaging
, 6
(3)
, Article 034003. 10.1117/1.JMI.6.3.034003.
|
R
Ramalhinho, J;
Tregidgo, H;
Allam, M;
Travlou, N;
Gurusamy, K;
Davidson, B;
Hawkes, D;
... Clarkson, M; + view all
(2019)
Registration of Untracked 2D Laparoscopic Ultrasound Liver Images to CT Using Content-Based Retrieval and Kinematic Priors.
In: Wang, Q and Gomez, A and Hutter, J and McLeod, K and Zimmer, V and Zettinig, O and Licandro, R and Robinson, E and Christiaens, D and Abaci Turk, E and Melbourne, A, (eds.)
Smart Ultrasound Imaging and Perinatal, Preterm and Paediatric Image Analysis.
(pp. pp. 11-19).
Springer: Shenzhen, China.
|
Ramasawmy, DR;
Cox, BT;
Treeby, B;
(2019)
The influence of strain-optic coefficients on the transduction mechanism of planar glass etalon Fabry-Perot ultrasound sensors.
In:
Proceedings of the 2019 IEEE International Ultrasonics Symposium (IUS).
(pp. pp. 2523-2526).
IEEE: Glasgow, Scotland, UK.
|
Ramasawmy, DR;
Martin, E;
Guggenheim, JA;
Zhang, EZ;
Beard, PC;
Treeby, BE;
Cox, BT;
(2019)
Analysis of the Directivity of Glass Etalon Fabry-Pérot Ultrasound Sensors.
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
10.1109/TUFFC.2019.2921735.
(In press).
|
Rau, A;
Edwards, PJE;
Ahmad, OF;
Riordan, P;
Janatka, M;
Lovat, LB;
Stoyanov, D;
(2019)
Implicit domain adaptation with conditional generative adversarial networks for depth prediction in endoscopy.
International Journal of Computer Assisted Radiology and Surgery
, 14
(7)
pp. 1167-1176.
10.1007/s11548-019-01962-w.
|
Rau, C;
Batey, D;
Cipiccia, S;
Shi, X;
Marathe, S;
Storm, M;
Bodey, A;
(2019)
New imaging opportunities at the DIAMOND beamline I13L.
In: Lai, B and Somogyi, A, (eds.)
X-Ray Nanoimaging: Instruments and Methods IV.
SPIE: San Diego, CA, USA.
|
Rau, C;
Storm, M;
Marathe, S;
Bodey, AJ;
Cipiccia, S;
Batey, D;
Shi, X;
... Zanette, I; + view all
(2019)
Multi-Scale Imaging at the Diamond Beamline I13.
In: Gwo, S and Huang, DJ and Wei, DH, (eds.)
Proceedings of the 13th International Conference on Synchrotron Radiation Instrumentation – SRI2018.
American Institute of Physics (AIP): Taipei, Taiwan.
|
Rau, C;
Storm, M;
Marathe, S;
Bodey, AJ;
Zdora, M;
Cipiccia, S;
Batey, D;
... Connolly, B; + view all
(2019)
Fast multi-scale imaging using the beamline I13L at the diamond light source.
In:
Proceedings of SPIE - The International Society for Optical Engineering.
SPIE: San Diego, California, USA.
|
Ravagli, E;
Mastitskaya, S;
Thompson, N;
Aristovich, KY;
Holder, DS;
(2019)
Optimization of the electrode drive pattern for imaging fascicular compound action potentials in peripheral nerve with fast neural electrical impedance tomography (EIT).
Physiological Measurement
10.1088/1361-6579/ab54eb.
(In press).
|
Ravi, D;
Ghavami, N;
Alexander, DC;
Ianus, A;
(2019)
Current Applications and Future Promises of Machine Learning in Diffusion MRI.
In: Frangi, Alejandro and Alberola-Lopez, Carlos and Porras, Antonio R, (eds.)
Proceedings of the 21st International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2018).
(pp. pp. 105-121).
Springer: Cham, Switzerland.
|
Ravi, D;
Szczotka, AB;
Pereira, SP;
Vercauteren, T;
(2019)
Adversarial training with cycle consistency for unsupervised super-resolution in endomicroscopy.
Medical Image Analysis
, 53
pp. 123-131.
10.1016/j.media.2019.01.011.
|
Rehman, F; Thomas, G; Anderlini, E; |