Percutaneous pulmonary valve implantation in humans - Results in 59 consecutive patients

Khambadkone, S; Coats, L; Taylor, A; Boudjemline, Y; Derrick, G; Tsang, V; Cooper, J; ... Bonhoeffer, P; + view all (2005) Percutaneous pulmonary valve implantation in humans - Results in 59 consecutive patients. CIRCULATION , 112 (8) 1189 - 1197. 10.1161/CIRCULATIONAHA.104.523266. Green open access

[thumbnail of 7376.pdf]
Preview
PDF
7376.pdf

Download (552kB)

Abstract

Background - Right ventricular outflow tract (RVOT) reconstruction with valved conduits in infancy and childhood leads to reintervention for pulmonary regurgitation and stenosis in later life.Methods and Results - Patients with pulmonary regurgitation with or without stenosis after repair of congenital heart disease had percutaneous pulmonary valve implantation (PPVI). Mortality, hemodynamic improvement, freedom from explantation, and subjective and objective changes in exercise tolerance were end points. PPVI was performed successfully in 58 patients, 32 male, with a median age of 16 years and median weight of 56 kg. The majority had a variant of tetralogy of Fallot (n = 36), or transposition of the great arteries, ventricular septal defect with pulmonary stenosis (n = 8). The right ventricular (RV) pressure (64.4 +/- 17.2 to 50.4 +/- 14 mm Hg, P < 0.001), RVOT gradient (33 +/- 24.6 to 19.5 +/- 15.3, P < 0.001), and pulmonary regurgitation ( PR) (grade 2 of greater before, none greater than grade 2 after, P < 0.001) decreased significantly after PPVI. MRI showed significant reduction in PR fraction (21 +/- 13% versus 3 +/- 4%, P < 0.001) and in RV end-diastolic volume (EDV) (94 +/- 28 versus 82 +/- 24 mL (.) beat(-1) (.) m(-2), P < 0.001) and a significant increase in left ventricular EDV ( 64 +/- 12 versus 71 +/- 13 mL (.) beat(-1.) m(-2), P = 0.005) and effective RV stroke volume ( 37 +/- 7 versus 42 +/- 9 mL (.) beat(-1) (.) m(-2), P = 0.006) in 28 patients (age 19 +/- 8 years). A further 16 subjects, on metabolic exercise testing, showed significant improvement in V(O2)max (26 +/- 7 versus 29 +/- 6 mL (.) kg(-1) (.) min(-1), P < 0.001). There was no mortality.Conclusions - PPVI is feasible at low risk, with quantifiable improvement in MRI-defined ventricular parameters and pulmonary regurgitation, and results in subjective and objective improvement in exercise capacity.

Type: Article
Title: Percutaneous pulmonary valve implantation in humans - Results in 59 consecutive patients
Open access status: An open access version is available from UCL Discovery
DOI: 10.1161/CIRCULATIONAHA.104.523266
Keywords: regurgitation, pulmonary valve insufficiency, magnetic resonance imaging, exercise testing, catheterization, RIGHT-VENTRICULAR-FUNCTION, OUTFLOW TRACT OBSTRUCTION, STENT IMPLANTATION, EXERCISE PERFORMANCE, PRIMARY REPAIR, ADULTS LATE, TETRALOGY, FALLOT, REPLACEMENT, REGURGITATION
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Childrens Cardiovascular Disease
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science
URI: https://discovery.ucl.ac.uk/id/eprint/7376
Downloads since deposit
687Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item