UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Refurbishment of a Victorian terraced house for energy efficiency

Dimitriou, A; (2006) Refurbishment of a Victorian terraced house for energy efficiency. Doctoral thesis , UCL (University College London). Green open access

[thumbnail of Dimitriou_thesis.pdf]
Preview
Text
Dimitriou_thesis.pdf

Download (7MB) | Preview

Abstract

The impacts of global warming are now obvious. The international community has committed itself to reduce CO2 emissions, the main contributor to the greenhouse effect, both at international and national levels. In the Kyoto Protocol signed in 1997, countries have committed to reduce their greenhouse gases emissions below their 1990 levels by the period 2008-2012. The UK specifically should reduce those emissions by 12.5%. Format reason, the UK has introduced a package of policies, which promote not only the use of renewable energy resources, but most importantly the reduction in energy use, with energy efficiency. Refurbishment of existing houses has and will contribute to the reduction of energy consumption. A Victorian mid-terraced house was studied in this report, and different refurbishment measures were tested, using two software programmes: TAS and SAP. The targets were to achieve certain levels of thermal comfort, to comply with the Building Regulation for building thermal elements and to achieve a high SAP rating. Then, the cost of each measure was calculated and its CO2 emissions were compared. Heat losses were mainly through the walls and roof. Roof and mainly wall refurbishment measures reduce the heating loads the most. Ground floor insulation does not contribute to the reduction of the heating loads, on the contrary it has detrimental effect in summer, where the cooling effect coming from the ground is being reduced. Window replacement achieves a very good performance in summer resulting in the reduction of overheating. Wall and roof insulation increase the SAP rating the most, between the building elements, but boiler replacement and upgrading of heating controls increase it more. According to the SAP rating, CO2 annual emissions are reduced the most by boiler replacement and then by wall and roof. The results given by the two softwares concerning which measure is more leads more to energy efficiency, are the same. Finally, if the measures which lead to the best energy performance are combined together, then the house could cut its energy bills by half, and could have 70% reduction in CO2 emissions.

Type: Thesis (Doctoral)
Title: Refurbishment of a Victorian terraced house for energy efficiency
Open access status: An open access version is available from UCL Discovery
Language: English
Additional information: Thesis digitised by ProQuest.
UCL classification:
URI: https://discovery.ucl.ac.uk/id/eprint/1569735
Downloads since deposit
156Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item