UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Accuracy of Cuff-Measured Blood Pressure: Systematic Reviews and Meta-Analyses

Picone, DS; Schultz, MG; Otahal, P; Aakhus, S; Al-Jumaily, AM; Black, JA; Bos, WJ; ... Sharman, JE; + view all (2017) Accuracy of Cuff-Measured Blood Pressure: Systematic Reviews and Meta-Analyses. Journal of the American College of Cardiology , 70 (5) pp. 572-586. 10.1016/j.jacc.2017.05.064. Green open access

[thumbnail of Hughes-A_accuracy of cuff_blood pressure_aam.pdf]
Preview
Text
Hughes-A_accuracy of cuff_blood pressure_aam.pdf - Accepted Version

Download (360kB) | Preview
[thumbnail of Hughes-A_accuracy of cuff_Online_supplement_24.5.17_trackedchanges.pdf]
Preview
Text
Hughes-A_accuracy of cuff_Online_supplement_24.5.17_trackedchanges.pdf - Accepted Version

Download (3MB) | Preview

Abstract

Background Hypertension (HTN) is the single greatest cardiovascular risk factor worldwide. HTN management is usually guided by brachial cuff blood pressure (BP), but questions have been raised regarding accuracy. Objectives This comprehensive analysis determined the accuracy of cuff BP and the consequent effect on BP classification compared with intra-arterial BP reference standards. Methods Three individual participant data meta-analyses were conducted among studies (from the 1950s to 2016) that measured intra-arterial aortic BP, intra-arterial brachial BP, and cuff BP. Results A total of 74 studies with 3,073 participants were included. Intra-arterial brachial systolic blood pressure (SBP) was higher than aortic values (8.0 mm Hg; 95% confidence interval [CI]: 5.9 to 10.1 mm Hg; p < 0.0001) and intra-arterial brachial diastolic BP was lower than aortic values (−1.0 mm Hg; 95% CI: −2.0 to −0.1 mm Hg; p = 0.038). Cuff BP underestimated intra-arterial brachial SBP (−5.7 mm Hg; 95% CI: −8.0 to −3.5 mm Hg; p < 0.0001) but overestimated intra-arterial diastolic BP (5.5 mm Hg; 95% CI: 3.5 to 7.5 mm Hg; p < 0.0001). Cuff and intra-arterial aortic SBP showed a small mean difference (0.3 mm Hg; 95% CI: −1.5 to 2.1 mm Hg; p = 0.77) but poor agreement (mean absolute difference 8.0 mm Hg; 95% CI: 7.1 to 8.9 mm Hg). Concordance between BP classification using the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure cuff BP (normal, pre-HTN, and HTN stages 1 and 2) compared with intra-arterial brachial BP was 60%, 50%, 53%, and 80%, and using intra-arterial aortic BP was 79%, 57%, 52%, and 76%, respectively. Using revised intra-arterial thresholds based on cuff BP percentile rank, concordance between BP classification using cuff BP compared with intra-arterial brachial BP was 71%, 66%, 52%, and 76%, and using intra-arterial aortic BP was 74%, 61%, 56%, and 65%, respectively. Conclusions Cuff BP has variable accuracy for measuring either brachial or aortic intra-arterial BP, and this adversely influences correct BP classification. These findings indicate that stronger accuracy standards for BP devices may improve cardiovascular risk management.

Type: Article
Title: Accuracy of Cuff-Measured Blood Pressure: Systematic Reviews and Meta-Analyses
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.jacc.2017.05.064
Publisher version: http://doi.org/10.1016/j.jacc.2017.05.064
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Blood pressure determination, hemodynamics, sphygmomanometers
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Population Science and Experimental Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/1567697
Downloads since deposit
112Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item