UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Accuracy of intracranial electrode placement for stereoencephalography: A systematic review and meta-analysis.

Vakharia, VN; Sparks, R; O'Keeffe, AG; Rodionov, R; Miserocchi, A; McEvoy, A; Ourselin, S; (2017) Accuracy of intracranial electrode placement for stereoencephalography: A systematic review and meta-analysis. Epilepsia , 58 (6) pp. 921-932. 10.1111/epi.13713. Green open access

[thumbnail of O'Keeffe_Manuscript SEEG meta-analysis_revisionclean1.pdf]
Preview
Text
O'Keeffe_Manuscript SEEG meta-analysis_revisionclean1.pdf - Accepted Version

Download (608kB) | Preview

Abstract

OBJECTIVE: Stereoencephalography (SEEG) is a procedure in which electrodes are inserted into the brain to help define the epileptogenic zone. This is performed prior to definitive epilepsy surgery in patients with drug-resistant focal epilepsy when noninvasive data are inconclusive. The main risk of the procedure is hemorrhage, which occurs in 1-2% of patients. This may result from inaccurate electrode placement or a planned electrode damaging a blood vessel that was not detected on the preoperative vascular imaging. Proposed techniques include the use of a stereotactic frame, frameless image guidance systems, robotic guidance systems, and customized patient-specific fixtures. METHODS: Using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, a structured search of the PubMed, Embase, and Cochrane databases identified studies that involve the following: (1) SEEG placement as part of the presurgical workup in patients with (2) drug-resistant focal epilepsy for which (3) accuracy data have been provided. RESULTS: Three hundred twenty-six publications were retrieved, of which 293 were screened following removal of duplicate and non-English-language studies. Following application of the inclusion and exclusion criteria, 15 studies were included in the qualitative and quantitative synthesis of the meta-analysis. Accuracies for SEEG electrode implantations have been combined using a random-effects analysis and stratified by technique. SIGNIFICANCE: The published literature regarding accuracy of SEEG implantation techniques is limited. There are no prospective controlled clinical trials comparing different SEEG implantation techniques. Significant systematic heterogeneity exists between the identified studies, preventing any meaningful comparison between techniques. The recent introduction of robotic trajectory guidance systems has been suggested to provide a more accurate method of implantation, but supporting evidence is limited to class 3 only. It is important that new techniques are compared to the previous "gold-standard" through well-designed and methodologically sound studies before they are introduced into widespread clinical practice.

Type: Article
Title: Accuracy of intracranial electrode placement for stereoencephalography: A systematic review and meta-analysis.
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1111/epi.13713
Publisher version: http://dx.doi.org/10.1111/epi.13713
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Drug resistance, Epileptogenic zone, Robotics, Stereoencephalography, Stereotactic frame
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Clinical and Experimental Epilepsy
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences > Dept of Statistical Science
URI: https://discovery.ucl.ac.uk/id/eprint/1544746
Downloads since deposit
142Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item