UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Clinical and methodological factors affecting non-transferrin-bound iron values using a novel fluorescent bead assay

Garbowski, MW; Ma, Y; Fucharoen, S; Srichairatanakool, S; Hider, R; Porter, JB; (2016) Clinical and methodological factors affecting non-transferrin-bound iron values using a novel fluorescent bead assay. Translational Research , 177 19-30.e5. 10.1016/j.trsl.2016.05.005. Green open access

[thumbnail of 1-s2.0-S1931524416300652-main.pdf]
Preview
Text
1-s2.0-S1931524416300652-main.pdf - Published Version

Download (2MB) | Preview

Abstract

Nontransferrin-bound iron (NTBI) is a heterogeneously speciated plasma iron, typically detectable when transferrin saturation (TfSat) exceeds 75%. Here, we examine factors affecting NTBI levels by a recently discovered direct chelator-based (CP851) fluorescent bead-linked flow-cytometric assay (bead-NTBI), compared with the established indirect nitrilotriacetate (NTA) assay in 122 iron-overloaded patients, including 64 on recent iron chelation therapy and 13 healthy volunteers. Both methods correlated (r = 0.57, P < 0.0001) but with low agreement, attributable to 2 major factors: (1) the NTA method, unlike the bead method, is highly dependent on TfSat, with NTBI under-estimation at low TfSat and over-estimation once Tf is saturated, (2) the bead method detects <3-fold higher values than the NTA assay in patients on recent deferiprone-containing chelation due to greater detection of chelate complexes but lower values for patients on deferasirox. The optimal timing of sample collection relative to chelation dosing requires further study. Patients with splenectomy, high-storage iron, and increased erythropoiesis had greater discrepancy between assays, consistent with differential access by both methods to the NTBI pools associated with these clinical variables. The bead-NTBI assay has advantages over the NTA assay, being less dependent on TfSat, hence of less tendency for false-negative or false-positive values at low and high TfSat, respectively.

Type: Article
Title: Clinical and methodological factors affecting non-transferrin-bound iron values using a novel fluorescent bead assay
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.trsl.2016.05.005
Publisher version: http://dx.doi.org/10.1016/j.trsl.2016.05.005
Language: English
Additional information: Copyright © 2016 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Cancer Institute
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Cancer Institute > Research Department of Haematology
URI: https://discovery.ucl.ac.uk/id/eprint/1517936
Downloads since deposit
113Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item