UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

A comparative study of blood endotoxin detection in haemodialysis patients

Wong, J; Davies, N; Jeraj, H; Vilar, E; Viljoen, A; Farrington, K; (2016) A comparative study of blood endotoxin detection in haemodialysis patients. Journal of Inflammation , 13 , Article 24. 10.1186/s12950-016-0132-5. Green open access

[thumbnail of Davies_s12950-016-0132-5.pdf]
Preview
Text
Davies_s12950-016-0132-5.pdf - Published Version

Download (655kB) | Preview

Abstract

BACKGROUND: Endotoxemia is commonly reported in patients receiving haemodialysis and implicated in the pathogenesis of systemic inflammation. The Limulus Amoebocyte Lysate (LAL) assay is the most commonly used blood endotoxin detection assay. Two kinetic variations of the assay are commercially available – the turbidimetric and chromogenic assay, it is unknown which assay is superior for endotoxin detection in uremic patients. Selection of the optimum LAL technique for endotoxin detection in haemodialysis patients is important to further understanding of the sequela of endotoxemia and development of endotoxin-lowering strategies in this population. METHOD: A turbidimetric and chromogenic LAL assay from the same manufacturer were directly compared. We investigated the ability of both LAL assays to detect endotoxin in uremic plasma. Plasma samples from haemodialysis patients and healthy controls were spiked with endotoxin and percentage spike recovery for the chromogenic and turbidimetric assay was determined. Assay accuracy and precision were compared between both LAL assays. RESULTS: The turbidimetric assay had greater accuracy than the chromogenic assay. Spike recovery was 113.8 % vs. 53.8 % for the turbidimetric and chromogenic assay respectively. Assay bias was higher in the chromogenic assay (−0.384EU/mL vs. 0.011EU/mL). The turbidimetric assay demonstrated greater precision compared to the chromogenic assay. Coefficient of variation ranged from 4.5 to 24.1 % for the turbidimetric assay and 25.8–26.5 % for the chromogenic assay. CONCLUSION: The study findings suggest that the kinetic turbidimetric LAL assay has greater accuracy and precision than the chromogenic assay and is the optimum LAL technique for endotoxin detection in haemodialysis patients, though these findings should be verified using LAL reagents from other sources.

Type: Article
Title: A comparative study of blood endotoxin detection in haemodialysis patients
Open access status: An open access version is available from UCL Discovery
DOI: 10.1186/s12950-016-0132-5
Publisher version: https://doi.org/10.1186/s12950-016-0132-5
Language: English
Additional information: © The Author(s). 2016. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
Keywords: Science & Technology, Life Sciences & Biomedicine, Immunology, Endotoxin, Haemodialysis, Inflammation, CHRONIC KIDNEY-DISEASE, PERITONEAL-DIALYSIS PATIENTS, AMEBOCYTE LYSATE LAL, SYSTEMIC INFLAMMATION, CIRCULATING ENDOTOXEMIA, ACTIVITY ASSAY, SEPTIC SHOCK, LIMULUS, PLASMA, FRAGMENTS
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Education
URI: https://discovery.ucl.ac.uk/id/eprint/1514967
Downloads since deposit
83Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item