Characterisation of a phantom for multiwavelength quantitative photoacoustic imaging

Fonseca, M; Zeqiri, B; Beard, PC; Cox, BT; (2016) Characterisation of a phantom for multiwavelength quantitative photoacoustic imaging. Physics in Medicine and Biology , 61 (13) pp. 4950-4973. 10.1088/0031-9155/61/13/4950. Green open access

[thumbnail of Cox_Fonseca_2016_Phys._Med._Biol._61_4950.pdf] Text
Cox_Fonseca_2016_Phys._Med._Biol._61_4950.pdf

Download (1MB)

Abstract

Quantitative photoacoustic imaging (qPAI) has the potential to provide high- resolution in vivo images of chromophore concentration, which may be indicative of tissue function and pathology. Many strategies have been proposed recently for extracting quantitative information, but many have not been experimentally verified. Experimental phantom-based validation studies can be used to test the robustness and accuracy of such algorithms in order to ensure reliable in vivo application is possible. The phantoms used in such studies must have well-characterised optical and acoustic properties similar to tissue, and be versatile and stable. Polyvinyl chloride plastisol (PVCP) has been suggested as a phantom for quality control and system evaluation. By characterising its multiwavelength optical properties, broadband acoustic properties and thermoelastic behaviour, this paper examines its potential as a phantom for qPAI studies too. PVCP's acoustic properties were assessed for various formulations, as well as its intrinsic optical absorption, and scattering with added TiO2, over a range of wavelengths from 400-2000 nm. To change the absorption coefficient, pigment-based chromophores that are stable during the phantom fabrication process, were used. These yielded unique spectra analogous to tissue chromophores and linear with concentration. At the high peak powers typically used in photoacoustic imaging, nonlinear optical absorption was observed. The Grüneisen parameter was measured to be $\Gamma$   =  1.01  ±  0.05, larger than typically found in tissue, though useful for increased PA signal. Single and multiwavelength 3D PA imaging of various fabricated PVCP phantoms were demonstrated.

Type: Article
Title: Characterisation of a phantom for multiwavelength quantitative photoacoustic imaging
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/0031-9155/61/13/4950
Publisher version: http://doi.org/10.1088/0031-9155/61/13/4950
Language: English
Additional information: © 2016 Institute of Physics and Engineering in Medicine. Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
Keywords: Science & Technology, Technology, Life Sciences & Biomedicine, Engineering, Biomedical, Radiology, Nuclear Medicine & Medical Imaging, Engineering, phantoms, quantitative photoacoustic imaging, polyvinyl chloride plastisol, acoustic properties, optical scattering, optical absorption, Grneisen paramet, ACOUSTIC PROPERTIES, OPTICAL-PROPERTIES, TOMOGRAPHY, SPECTROSCOPY, WATER
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/1508950
Downloads since deposit
98Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item