UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Development and Phantom Validation of a 3D-Ultrasound-Guided System for Targeting MRI-visible Lesions during Transrectal Prostate Biopsy

Hu, Y; Kasivisvanathan, V; Simmons, L; Clarkson, M; Thompson, S; Shah, T; Ahmed, H; ... Barratt, D; + view all (2017) Development and Phantom Validation of a 3D-Ultrasound-Guided System for Targeting MRI-visible Lesions during Transrectal Prostate Biopsy. IEEE Transactions on Biomedical Engineering , 64 (4) pp. 946-958. 10.1109/TBME.2016.2582734. Green open access

[thumbnail of Hu et al 2016 Development and Phantom Validation of a 3D-Ultrasound-Guided System for Targeting MRI-visible Lesions during Transrectal Prostate Biopsy.pdf]
Preview
Text
Hu et al 2016 Development and Phantom Validation of a 3D-Ultrasound-Guided System for Targeting MRI-visible Lesions during Transrectal Prostate Biopsy.pdf

Download (1MB) | Preview

Abstract

OBJECTIVE: Three- and four-dimensional transrectal ultrasound transducers are now available from most major ultrasound equipment manufacturers, but currently are incorporated into only one commercial prostate biopsy guidance system. Such transducers offer the benefits of rapid volumetric imaging, but can cause substantial measurement distortion in electromagnetic tracking sensors, which are commonly used to enable 3D navigation. In this paper, we describe the design, development and validation of a 3D-ultrasound-guided transrectal prostate biopsy system that employs high-accuracy optical tracking to localize the ultrasound probe and prostate targets in 3D physical space. METHODS: The accuracy of the system was validated by evaluating the targeted needle placement error after inserting a biopsy needle to sample planned targets in a phantom using standard 2D ultrasound guidance versus real-time 3D guidance provided by the new system. RESULTS: The overall mean needle-segment-to-target distance error was 3.6±4.0 mm and mean needle-to-target distance was 3.2±2.4 mm. CONCLUSION: a significant increase in needle placement accuracy was observed when using the 3D guidance system compared with visual targeting of invisible (virtual) lesions using a standard B-mode ultrasound guided biopsy technique.

Type: Article
Title: Development and Phantom Validation of a 3D-Ultrasound-Guided System for Targeting MRI-visible Lesions during Transrectal Prostate Biopsy
Open access status: An open access version is available from UCL Discovery
DOI: 10.1109/TBME.2016.2582734
Publisher version: http://dx.doi.org/10.1109/TBME.2016.2582734
Language: English
Additional information: Copyright © 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
Keywords: prostate cancer, image-guided interventions, image registration, tracking, transrectal biopsy
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Targeted Intervention
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/1498975
Downloads since deposit
246Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item