UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Flexible active electrode arrays with ASICs that fit inside the rat's spinal canal

Giagka, V; Demosthenous, A; Donaldson, N; (2015) Flexible active electrode arrays with ASICs that fit inside the rat's spinal canal. Biomedical Microdevices , 17 , Article 106. 10.1007/s10544-015-0011-5. Green open access

[thumbnail of Flexible active electrode arrays with ASICs that fit inside the rat's spinal canal.pdf]
Preview
Text
Flexible active electrode arrays with ASICs that fit inside the rat's spinal canal.pdf - Published Version

Download (4MB) | Preview

Abstract

Epidural spinal cord electrical stimulation (ESCS) has been used as a means to facilitate locomotor recovery in spinal cord injured humans. Electrode arrays, instead of conventional pairs of electrodes, are necessary to investigate the effect of ESCS at different sites. These usually require a large number of implanted wires, which could lead to infections. This paper presents the design, fabrication and evaluation of a novel flexible active array for ESCS in rats. Three small (1.7 mm2) and thin (100 μm) application specific integrated circuits (ASICs) are embedded in the polydimethylsiloxane-based implant. This arrangement limits the number of communication tracks to three, while ensuring maximum testing versatility by providing independent access to all 12 electrodes in any configuration. Laser-patterned platinum-iridium foil forms the implant’s conductive tracks and electrodes. Double rivet bonds were employed for the dice microassembly. The active electrode array can deliver current pulses (up to 1 mA, 100 pulses per second) and supports interleaved stimulation with independent control of the stimulus parameters for each pulse. The stimulation timing and pulse duration are very versatile. The array was electrically characterized through impedance spectroscopy and voltage transient recordings. A prototype was tested for long term mechanical reliability when subjected to continuous bending. The results revealed no track or bond failure. To the best of the authors’ knowledge, this is the first time that flexible active electrode arrays with embedded electronics suitable for implantation inside the rat’s spinal canal have been proposed, developed and tested in vitro.

Type: Article
Title: Flexible active electrode arrays with ASICs that fit inside the rat's spinal canal
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s10544-015-0011-5
Publisher version: http://dx.doi.org/10.1007/s10544-015-0011-5
Language: English
Additional information: Copyright © The Author(s) 2015. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Keywords: Active flexible electrode arrays, Application specific integrated circuits, Epidural stimulation, Laser patterned microelectrodes, Neurorehabilitation, Rivet bonding
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Electronic and Electrical Eng
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/1483830
Downloads since deposit
88Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item