The effect of respiratory induced density variations on non-TOF PET quantitation in the lung

Holman, BF; Cuplov, V; Hutton, BF; Groves, AM; Thielemans, K; (2016) The effect of respiratory induced density variations on non-TOF PET quantitation in the lung. Physics in Medicine and Biology , 61 (8) pp. 3148-3163. 10.1088/0031-9155/61/8/3148. Green open access

[thumbnail of Thielemans_pmb_61_8_3148_redacted.pdf]
Preview
Text
Thielemans_pmb_61_8_3148_redacted.pdf

Download (534kB) | Preview

Abstract

Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant (18)F-FDG and (18)F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.

Type: Article
Title: The effect of respiratory induced density variations on non-TOF PET quantitation in the lung
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/0031-9155/61/8/3148
Publisher version: http://dx.doi.org/10.1088/0031-9155/61/8/3148
Language: English
Additional information: Copyright © 2016 Institute of Physics and Engineering in Medicine. Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence (http://creativecommons.org/licenses/by/3.0). Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Experimental and Translational Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/1481219
Downloads since deposit
83Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item