UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Registration of prostate surfaces for image-guided robotic surgery via the da Vinci System

Sioutis, I; (2015) Registration of prostate surfaces for image-guided robotic surgery via the da Vinci System. Doctoral thesis , UCL (University College London). Green open access

[thumbnail of Edited_Version_Thesis_IliasSioutis.pdf]
Preview
Text
Edited_Version_Thesis_IliasSioutis.pdf

Download (3MB) | Preview

Abstract

Organ-confined prostate cancer represents a commonly diagnosed cancer among men rendering an early diagnosis and screening a necessity. The prostate laparoscopic surgery using the da Vinci system is a minimally invasive, computer assisted and image-guided surgery application that provides surgeons with (i) navigational assistance by displaying targeting lesions of the intraoperative prostate anatomy onto aligned preoperative high-field magnetic resonance imaging (MRI) scans of the pelvis; and (ii) an effective clinical management of intra-abdominal cancers in real time. Such an image guidance system can improve both functional and oncological outcomes as well as augment the learning curve of the process increasing simultaneously the eligibility of patients for surgical resection. By segmenting MRI scans into 3D models of intraprostatic anatomy preoperatively, and overlaying them onto 3D stereoendoscopic images acquired intraoperatively using the da Vinci surgical system, a graphical representation of intraoperative anatomy can be provided for surgical navigation. The preoperative MRI surfaces are full 3D models and the stereoendoscopic images represent partial 3D views of the prostate due to occlusion. Hence achieving an accurate non-rigid image registration of full prostate surfaces onto occluded ones in real time becomes of critical importance, especially for use intraoperatively with the stereoendoscopic and MRI imaging modalities. This work exploits the registration accuracy that can be achieved from the application of selected state-of-the-art non-rigid registration algorithms and in doing so identifies the most accurate technique(s) for registration of full prostate surfaces onto occluded ones; a series of rigorous computational registration experiments is performed on synthetic target prostate data, which are aligned manually onto the MRI prostate models before registration is initiated. This effort extends to using real target prostate data leading to visually acceptable non-rigid registration results. A great deal of emphasis is placed on examining the capacity of the selected non-rigid algorithms to recover the deformation of the intraoperative prostate surfaces; the deformation of prostate can become pronounced during the surgical intervention due to surgical-induced anatomical deformities and pathological or other factors. The warping accuracy of the non-rigid registration algorithms is measured within the space of common overlap (established between the full MRI model and the target scene) and beyond. From the results of the registrations to occluded and deformed prostate surfaces (in the space beyond common overlap) it is concluded that the modified versions of the Kernel Correlation/Thin-plane Spline (KC/TPS) and Gaussian Mixture Model/Thin-plane Spline (GMM/TPS) methodologies can provide the clinical accuracy required for image-guided prostate surgery procedures (performed by the da Vinci system) as long as the size of the target scene is greater than ca. 30% of the full MRI surface. For the modified KC/TPS and GMM/TPS non-rigid registration techniques to be clinically acceptable when the measurement noise is also included in the simulations: (i) the size of the target model must be greater than ca. 38% of the full MRI surface; (ii) the standard deviation σ of the contributing Gaussian noise must be less than 0.345 for μ=0; and (iii) the observed deformation must not be characterized by excessively increased complexity. Otherwise the contribution of Gaussian noise must be explicitly parameterized in the objective cost functions of these non-rigid algorithms. The Expectation Maximization/Thin-plane Spline (EM/TPS) non-rigid registration algorithm cannot recover the prostate surface deformation accurately in full-model-to-occluded-model registrations due to the way that the correspondences are estimated. However, EM/TPS is more accurate than KC+TPS and GMM+TPS in recovering the deformation of the prostate surface in full-model-to-full-model registrations.

Type: Thesis (Doctoral)
Title: Registration of prostate surfaces for image-guided robotic surgery via the da Vinci System
Event: UCL
Open access status: An open access version is available from UCL Discovery
Language: English
Additional information: Third party copyright material has been removed from ethesis.
UCL classification: UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Computer Science
URI: https://discovery.ucl.ac.uk/id/eprint/1471002
Downloads since deposit
188Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item