UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Quantitative multi-parameter mapping of R1, PD*, MT and R2* at 3T: a multi-center validation.

Weiskopf, N; Weiskopf, N; Suckling, J; Williams, G; Correia, MM; Inkster, B; Tait, R; ... Lutti, A; + view all (2013) Quantitative multi-parameter mapping of R1, PD*, MT and R2* at 3T: a multi-center validation. Frontiers in Neuroscience , 7 95 -. 10.3389/fnins.2013.00095. Green open access

[thumbnail of 1395683.pdf]
Preview
PDF
1395683.pdf

Download (2MB)

Abstract

Multi-center studies using magnetic resonance imaging facilitate studying small effect sizes, global population variance and rare diseases. The reliability and sensitivity of these multi-center studies crucially depend on the comparability of the data generated at different sites and time points. The level of inter-site comparability is still controversial for conventional anatomical T1-weighted MRI data. Quantitative multi-parameter mapping (MPM) was designed to provide MR parameter measures that are comparable across sites and time points, i.e., 1 mm high-resolution maps of the longitudinal relaxation rate (R1 = 1/T1), effective proton density (PD*), magnetization transfer saturation (MT) and effective transverse relaxation rate (R2* = 1/T2*). MPM was validated at 3T for use in multi-center studies by scanning five volunteers at three different sites. We determined the inter-site bias, inter-site and intra-site coefficient of variation (CoV) for typical morphometric measures [i.e., gray matter (GM) probability maps used in voxel-based morphometry] and the four quantitative parameters. The inter-site bias and CoV were smaller than 3.1 and 8%, respectively, except for the inter-site CoV of R2* (<20%). The GM probability maps based on the MT parameter maps had a 14% higher inter-site reproducibility than maps based on conventional T1-weighted images. The low inter-site bias and variance in the parameters and derived GM probability maps confirm the high comparability of the quantitative maps across sites and time points. The reliability, short acquisition time, high resolution and the detailed insights into the brain microstructure provided by MPM makes it an efficient tool for multi-center imaging studies.

Type: Article
Title: Quantitative multi-parameter mapping of R1, PD*, MT and R2* at 3T: a multi-center validation.
Open access status: An open access version is available from UCL Discovery
DOI: 10.3389/fnins.2013.00095
Publisher version: http://dx.doi.org/10.3389/fnins.2013.00095
Language: English
Additional information: This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in other forums, provided the original authors and source are credited and subject to any copyright notices concerning any third-party graphics etc.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Imaging Neuroscience
URI: https://discovery.ucl.ac.uk/id/eprint/1395683
Downloads since deposit
208Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item