Di Leonardo, Sofia;
Vella, Danila;
Pisano, Calogera;
Argano, Vincenzo;
Burriesci, Gaetano;
(2025)
Hydrodynamic Alterations Produced by Subaortic Membranes: An in Vitro Study.
IRBM
, 46
(4)
, Article 100897. 10.1016/j.irbm.2025.100897.
Preview |
PDF
1-s2.0-S1959031825000223-main.pdf - Published Version Download (2MB) | Preview |
Abstract
Background: Subaortic stenosis is an aortic disease characterised by the presence of a membrane located at the aortic valve inlet, that causes a sudden reduction of the inflow lumen. The membrane develops as a tissue growth of variable thickness that can cause a major increase in the pressure gradient. In this case, when diagnosed, it is removed by surgical resection. Methods: To investigate the haemodynamic alteration introduced by subaortic membranes, an in vitro study was designed and performed. Stiff and flexible membranes were implanted at the inlet of a bioprosthetic control valve. These mock membranes had different radial and angular alignment, modelling concentric and eccentric orifice positions. For each configuration, a range of different membrane extensions was studied, progressively reducing the orifice area at the inlet of the control valve. Results: Analysis of the hydrodynamic performances indicates that the detrimental effect of subaortic membranes becomes significant when the membrane orifice areas reduce below 75% of the unobstructed inflow lumen. Video analysis of the valve leaflets dynamics indicates that, together with a worsening in the systolic pressure gradient, the presence of subaortic membranes increases cusps fluttering. As the membrane orifice area reduces, leaflets experience faster oscillation frequencies at decreasing amplitudes. Conclusions: The fibromuscular or thin nature of the membrane has a significant role on the severity of the pathology, with higher stiffnesses generally producing worse hydrodynamics. The orifice dimension and position are also important on the systolic performance and can determine potential structural degradation and haematic damage.
Type: | Article |
---|---|
Title: | Hydrodynamic Alterations Produced by Subaortic Membranes: An in Vitro Study |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.irbm.2025.100897 |
Publisher version: | https://doi.org/10.1016/j.irbm.2025.100897 |
Language: | English |
Additional information: | This work is licensed under a Creative Commons License. The images or other third-party material in this article are included in the Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
Keywords: | Subaortic stenosis, Subaortic membrane, In vitro analysis, Hydrodynamic performance, Leaflet fluttering |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering |
URI: | https://discovery.ucl.ac.uk/id/eprint/10209374 |
Archive Staff Only
![]() |
View Item |