UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Assistive technologies, including orthotic devices, for the management of contractures in adults after a stroke

Mohammed Meeran, RA; Durairaj, V; Sekaran, P; Farmer, SE; Pandyan, AD; (2024) Assistive technologies, including orthotic devices, for the management of contractures in adults after a stroke. Cochrane Database of Systematic Reviews , 2024 (9) , Article CD010779. 10.1002/14651858.CD010779.pub2.

[thumbnail of Meeran_et_al-2024-Cochrane_Database_of_Systematic_Reviews.pdf] Text
Meeran_et_al-2024-Cochrane_Database_of_Systematic_Reviews.pdf - Accepted Version
Access restricted to UCL open access staff until 24 September 2025.

Download (791kB)

Abstract

Background: Contractures (reduced range of motion and increased stiffness of a joint) are a frequent complication of stroke. Contractures can interfere with function and cause cosmetic and hygiene problems. Preventing and managing contractures might improve rehabilitation and recovery after stroke. Objectives: To assess the effects of assistive technologies for the management of contractures in adults after a stroke. Search methods: We searched CENTRAL, MEDLINE, Embase, five other databases, and three trials registers in May 2022. We also searched for reference lists of relevant studies, contacted experts in the field, and ran forward citation searches. Selection criteria: Randomised controlled studies (RCTs) that used electrical, mechanical, or electromechanical devices to manage contractures in adults with stroke were eligible for inclusion in this review. We planned to include studies that compared assistive technologies against no treatment, routine therapy, or another assistive technology. Data collection and analysis: Three review authors (working in pairs) selected all studies, extracted data, and assessed risk of bias. The primary outcomes were passive joint range of motion (PROM) with and without standardised force, and indirect measures of PROM. The secondary outcomes included hygiene. We also wanted to evaluate the adverse effects of assistive technology. Effects were expressed as mean differences (MDs) or standardised mean differences (SMDs) with 95% confidence intervals (CIs). Main results: Seven studies fulfilled the inclusion criteria. Five of these were meta-analysed; they included 252 adults treated in acute and subacute rehabilitation settings. All studies compared assistive technology with routine therapy; one study also compared assistive technology with no treatment, but we were unable to obtain separate data for stroke participants. The assistive technologies used in the studies were electrical stimulation, splinting, positioning using a hinged board, and active repetitive motor training using a non-robotic device with electrical stimulation. Only one study applied stretching to end range. Treatment duration ranged from four to 12 weeks. The overall risk of bias was high for all studies. We are uncertain whether:. • electrical stimulation to wrist extensors improves passive range of wrist extension (MD −7.30°, 95% CI −18.26° to 3.66°; 1 study, 81 participants; very low-certainty evidence);
• a non-robotic device with electrical stimulation to shoulder flexors improves passive range of shoulder flexion (MD −9.00°, 95% CI −25.71° to 7.71°; 1 study; 50 participants; very low-certainty evidence);
• assistive technology improves passive range of wrist extension with standardised force (SMD −0.05, 95% CI −0.39 to 0.29; four studies, 145 participants; very low-certainty evidence):
• a non-robotic device with electrical stimulation to elbow extensors improves passive range of elbow extension (MD 0.41°, 95% CI −0.15° to 0.97°; 1 study, 50 participants; very low-certainty evidence). One study reported the adverse outcome of pain when using a hinged board to apply stretch to wrist and finger flexors, and another study reported skin breakdown when using a thumb splint. No studies reported hygiene or indirect measures of PROM. Authors' conclusions: Only seven small RCTs met the eligibility criteria of this review, and all provided very low-certainty evidence. Consequently, we cannot draw firm conclusions on the effects of assistive technology compared with routine therapy or no therapy. It was also difficult to confirm whether there is a risk of harm associated with treatment using assistive technology. Future studies should apply adequate treatment intensity (i.e. magnitude and the duration of stretch) and use valid and reliable outcome measures. Such studies might better identify the role of assistive technology in the management of contractures in adults after a stroke.

Type: Article
Title: Assistive technologies, including orthotic devices, for the management of contractures in adults after a stroke
Location: England
DOI: 10.1002/14651858.CD010779.pub2
Publisher version: http://dx.doi.org/10.1002/14651858.cd010779.pub2
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Adult, Humans, Bias, Contracture, Orthotic Devices, Randomized Controlled Trials as Topic, Range of Motion, Articular, Self-Help Devices, Stroke, Stroke Rehabilitation
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Clinical and Movement Neurosciences
URI: https://discovery.ucl.ac.uk/id/eprint/10199051
Downloads since deposit
1Download
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only