Image quality assessment for closed-loop computer-assisted lung ultrasound.
arXiv.org: Ithaca (NY), USA.
Preview |
Text
Parker_Image quality assessment for closed-loop computer-assisted lung ultrasound_pre-print.pdf Download (397kB) | Preview |
Abstract
We describe a novel, two-stage computer assistance system for lung anomaly detection using ultrasound imaging in the intensive care setting to improve operator performance and patient stratification during coronavirus pandemics. The proposed system consists of two deep-learning-based models: a quality assessment module that automates predictions of image quality, and a diagnosis assistance module that determines the likelihood-oh-anomaly in ultrasound images of sufficient quality. Our two-stage strategy uses a novelty detection algorithm to address the lack of control cases available for training the quality assessment classifier. The diagnosis assistance module can then be trained with data that are deemed of sufficient quality, guaranteed by the closed-loop feedback mechanism from the quality assessment module. Using more than 25000 ultrasound images from 37 COVID-19-positive patients scanned at two hospitals, plus 12 control cases, this study demonstrates the feasibility of using the proposed machine learning approach. We report an accuracy of 86% when classifying between sufficient and insufficient quality images by the quality assessment module. For data of sufficient quality - as determined by the quality assessment module - the mean classification accuracy, sensitivity, and specificity in detecting COVID-19-positive cases were 0.95, 0.91, and 0.97, respectively, across five holdout test data sets unseen during the training of any networks within the proposed system. Overall, the integration of the two modules yields accurate, fast, and practical acquisition guidance and diagnostic assistance for patients with suspected respiratory conditions at point-of-care.
Type: | Working / discussion paper |
---|---|
Title: | Image quality assessment for closed-loop computer-assisted lung ultrasound |
Open access status: | An open access version is available from UCL Discovery |
Publisher version: | https://arxiv.org/abs/2008.08840v2 |
Language: | English |
Additional information: | This version is the version of record. For information on re-use, please refer to the publisher's terms and conditions. |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng |