UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Tissue Equivalent Curved Organic X-ray Detectors Utilizing High Atomic Number Polythiophene Analogues

Nanayakkara, M Prabodhi A; He, Qiao; Ruseckas, Arvydas; Karalasingam, Anushanth; Matjacic, Lidija; Masteghin, Mateus G; Basiricò, Laura; ... Silva, S Ravi P; + view all (2023) Tissue Equivalent Curved Organic X-ray Detectors Utilizing High Atomic Number Polythiophene Analogues. Advanced Science , Article 2304261. 10.1002/advs.202304261. (In press). Green open access

[thumbnail of Tissue Equivalent Curved Organic X ray Detectors.pdf]
Preview
Text
Tissue Equivalent Curved Organic X ray Detectors.pdf - Published Version

Download (4MB) | Preview

Abstract

Organic semiconductors are a promising material candidate for X-ray detection. However, the low atomic number (Z) of organic semiconductors leads to poor X-ray absorption thus restricting their performance. Herein, the authors propose a new strategy for achieving high-sensitivity performance for X-ray detectors based on organic semiconductors modified with high –Z heteroatoms. X-ray detectors are fabricated with p-type organic semiconductors containing selenium heteroatoms (poly(3-hexyl)selenophene (P3HSe)) in blends with an n-type fullerene derivative ([6,6]-Phenyl C71 butyric acid methyl ester (PC70BM). When characterized under 70, 100, 150, and 220 kVp X-ray radiation, these heteroatom-containing detectors displayed a superior performance in terms of sensitivity up to 600 ± 11 nC Gy−1 cm−2 with respect to the bismuth oxide (Bi2O3) nanoparticle (NP) sensitized organic detectors. Despite the lower Z of selenium compared to the NPs typically used, the authors identify a more efficient generation of electron-hole pairs, better charge transfer, and charge transport characteristics in heteroatom-incorporated detectors that result in this breakthrough detector performance. The authors also demonstrate flexible X-ray detectors that can be curved to a radius as low as 2 mm with low deviation in X-ray response under 100 repeated bending cycles while maintaining an industry-standard ultra-low dark current of 0.03 ± 0.01 pA mm−2.

Type: Article
Title: Tissue Equivalent Curved Organic X-ray Detectors Utilizing High Atomic Number Polythiophene Analogues
Location: Germany
Open access status: An open access version is available from UCL Discovery
DOI: 10.1002/advs.202304261
Publisher version: https://doi.org/10.1002/advs.202304261
Language: English
Additional information: Copyright © 2023 The Authors. Advanced Science published by Wiley-VCH GmbH This is an open access article under the terms of the Creative Commons Attribution License, https://creativecommons.org/licenses/by/4.0/, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Keywords: Flexible; heteroatom; organic electronics; photonics; x-ray detectors
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10180903
Downloads since deposit
9Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item