Huang, Xiaoqin; Sun, Jian; Gupta, Krati; Montesano, Giovanni; Crabb, David P; Garway-Heath, David F; Brusini, Paolo; ... Yousefi, Siamak; + view all (2022) Detecting glaucoma from multi-modal data using probabilistic deep learning. Frontiers in Medicine , 9 , Article 923096. 10.3389/fmed.2022.923096. Green open access

[thumbnail of Garwa y Heath_Detecting glaucoma from multi-modal data using probabilistic deep learning_VoR.pdf]
Preview
Text
Garwa y Heath_Detecting glaucoma from multi-modal data using probabilistic deep learning_VoR.pdf - Published Version

Download (3MB) | Preview

Abstract

Objective: To assess the accuracy of probabilistic deep learning models to discriminate normal eyes and eyes with glaucoma from fundus photographs and visual fields. Design: Algorithm development for discriminating normal and glaucoma eyes using data from multicenter, cross-sectional, case-control study. Subjects and participants: Fundus photograph and visual field data from 1,655 eyes of 929 normal and glaucoma subjects to develop and test deep learning models and an independent group of 196 eyes of 98 normal and glaucoma patients to validate deep learning models. Main outcome measures: Accuracy and area under the receiver-operating characteristic curve (AUC). Methods: Fundus photographs and OCT images were carefully examined by clinicians to identify glaucomatous optic neuropathy (GON). When GON was detected by the reader, the finding was further evaluated by another clinician. Three probabilistic deep convolutional neural network (CNN) models were developed using 1,655 fundus photographs, 1,655 visual fields, and 1,655 pairs of fundus photographs and visual fields collected from Compass instruments. Deep learning models were trained and tested using 80% of fundus photographs and visual fields for training set and 20% of the data for testing set. Models were further validated using an independent validation dataset. The performance of the probabilistic deep learning model was compared with that of the corresponding deterministic CNN model. Results: The AUC of the deep learning model in detecting glaucoma from fundus photographs, visual fields, and combined modalities using development dataset were 0.90 (95% confidence interval: 0.89–0.92), 0.89 (0.88–0.91), and 0.94 (0.92–0.96), respectively. The AUC of the deep learning model in detecting glaucoma from fundus photographs, visual fields, and both modalities using the independent validation dataset were 0.94 (0.92–0.95), 0.98 (0.98–0.99), and 0.98 (0.98–0.99), respectively. The AUC of the deep learning model in detecting glaucoma from fundus photographs, visual fields, and both modalities using an early glaucoma subset were 0.90 (0.88,0.91), 0.74 (0.73,0.75), 0.91 (0.89,0.93), respectively. Eyes that were misclassified had significantly higher uncertainty in likelihood of diagnosis compared to eyes that were classified correctly. The uncertainty level of the correctly classified eyes is much lower in the combined model compared to the model based on visual fields only. The AUCs of the deterministic CNN model using fundus images, visual field, and combined modalities based on the development dataset were 0.87 (0.85,0.90), 0.88 (0.84,0.91), and 0.91 (0.89,0.94), and the AUCs based on the independent validation dataset were 0.91 (0.89,0.93), 0.97 (0.95,0.99), and 0.97 (0.96,0.99), respectively, while the AUCs based on an early glaucoma subset were 0.88 (0.86,0.91), 0.75 (0.73,0.77), and 0.92 (0.89,0.95), respectively. Conclusion and relevance: Probabilistic deep learning models can detect glaucoma from multi-modal data with high accuracy. Our findings suggest that models based on combined visual field and fundus photograph modalities detects glaucoma with higher accuracy. While probabilistic and deterministic CNN models provided similar performance, probabilistic models generate certainty level of the outcome thus providing another level of confidence in decision making.

Type: Article
Title: Detecting glaucoma from multi-modal data using probabilistic deep learning
Location: Switzerland
Open access status: An open access version is available from UCL Discovery
DOI: 10.3389/fmed.2022.923096
Publisher version: https://doi.org/10.3389/fmed.2022.923096
Language: English
Additional information: Copyright © 2022 Huang, Sun, Gupta, Montesano, Crabb, Garway-Heath, Brusini, Lanzetta, Oddone, Turpin, McKendrick, Johnson and Yousefi. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
Keywords: Science & Technology, Life Sciences & Biomedicine, Medicine, General & Internal, General & Internal Medicine, deep learning, artificial intelligence, glaucoma, fundus photograph, visual field, automated diagnosis, RETINAL NERVE-FIBER, VISUAL-FIELD DEFECTS, DISC RATIO, CUP, CLASSIFIERS, VARIABILITY, AGREEMENT, DIAGNOSIS, LAYER, HEAD
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > Institute of Ophthalmology
URI: https://discovery.ucl.ac.uk/id/eprint/10165678
Downloads since deposit
8Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item