Mind the gap between non-activated (non-aggressive) and activated (aggressive) indoor fungal testing: impact of pre-sampling environmental settings on indoor air readings

Efthymiopoulos, S.; Aktas, Y.D.; Altamirano, H.; (2023) Mind the gap between non-activated (non-aggressive) and activated (aggressive) indoor fungal testing: impact of pre-sampling environmental settings on indoor air readings. UCL Open: Environment , 5 , Article 2. 10.14324/111.444/ucloe.000055. Green open access

[thumbnail of ucloe-05-055.pdf]
Preview
Text
ucloe-05-055.pdf - Published Version

Download (4MB) | Preview

Abstract

Indoor fungal testing has been within the researchers’ scope of interest for more than a century. Various sampling and analysis techniques have been developed over the years, but no testing protocol has been yet standardised and widely accepted by the research and practitioner communities. The diversity in fungal taxa within buildings with varied biological properties and implications on the health and wellbeing of the occupants and the building fabric complicates the decision-making process for selecting an appropriate testing protocol. This study aims to present a critical review of non-activated and activated approaches to indoor testing, with an emphasis on the preparation of the indoor environment prior to sampling. The study demonstrates the differences in the outcomes of non-activated and activated testing through a set of laboratory experiments in idealised conditions and a case study. The findings suggest that larger particles are particularly sensitive to the sampling height and activation, and that non-activated protocols, despite dominating the current literature, can significantly underestimate the fungal biomass and species richness. Therefore, this paper calls for better-defined and activated protocols that can enhance robustness and reproducibility across the research domain focused on indoor fungal testing.

Type: Article
Title: Mind the gap between non-activated (non-aggressive) and activated (aggressive) indoor fungal testing: impact of pre-sampling environmental settings on indoor air readings
Open access status: An open access version is available from UCL Discovery
DOI: 10.14324/111.444/ucloe.000055
Publisher version: https://doi.org/10.14324/111.444/ucloe.000055
Language: English
Additional information: © 2023 The Authors. This is an open access article distributed under the terms of the Creative Commons Attribution Licence (CC BY) 4.0 https://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
Keywords: mould, fungal testing, particles, indoor fungi, activated, non-activated, fungal growth assessment
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Civil, Environ and Geomatic Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10165188
Downloads since deposit
41Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item