Standard care vs. TRIVEntricular pacing in Heart Failure (STRIVE HF): a prospective multicentre randomized controlled trial of triventricular pacing vs. conventional biventricular pacing in patients with heart failure and intermediate QRS left bundle branch block.
EP Europace
, 24
(5)
pp. 796-806.
10.1093/europace/euab267.
Preview |
Text
Lambiase_euab267.pdf - Published Version Download (1MB) | Preview |
Abstract
AIMS: To determine whether triventricular (TriV) pacing is feasible and improves CRT response compared to conventional biventricular (BiV) pacing in patients with left bundle branch block (LBBB) and intermediate QRS prolongation (120-150 ms). METHODS AND RESULTS: Between October 2015 and November 2019, 99 patients were recruited from 11 UK centres. Ninety-five patients were randomized 1:1 to receive TriV or BiV pacing systems. The primary endpoint was feasibility of TriV pacing. Secondary endpoints assessed symptomatic and remodelling response to CRT. Baseline characteristics were balanced between groups. In the TriV group, 43/46 (93.5%) patients underwent successful implantation vs. 47/49 (95.9%) in the BiV group. Feasibility of maintaining CRT at 6 months was similar in the TriV vs. BiV group (90.0% vs. 97.7%, P = 0.191). All-cause mortality was similar between TriV vs. BiV groups (4.3% vs. 8.2%, P = 0.678). There were no significant differences in echocardiographic LV volumes or clinical composite scores from baseline to 6-month follow-up between groups. CONCLUSION: Implantation of two LV leads to deliver and maintain TriV pacing at 6 months is feasible without significant complications in the majority of patients. There was no evidence that TriV pacing improves CRT response or provides additional clinical benefit to patients with LBBB and intermediate QRS prolongation and cannot be recommended in this patient group. CLINICAL TRIAL REGISTRATION NUMBER: Clinicaltrials.gov: NCT02529410.
Type: | Article |
---|---|
Title: | Standard care vs. TRIVEntricular pacing in Heart Failure (STRIVE HF): a prospective multicentre randomized controlled trial of triventricular pacing vs. conventional biventricular pacing in patients with heart failure and intermediate QRS left bundle branch block |
Location: | England |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1093/europace/euab267 |
Publisher version: | https://doi.org/10.1093/europace/euab267 |
Language: | English |
Additional information: | Copyright © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
Keywords: | Cardiac resynchronization therapy, Multi-site pacing, Multi-lead left ventricular pacing, Triventricular pacing, Improving cardiac resynchronization therapy response |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences |
URI: | https://discovery.ucl.ac.uk/id/eprint/10149841 |
Archive Staff Only
View Item |