UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal

Hakim, Uzair; Pinti, Paola; Noah, Adam J; Zhang, Xian; Burgess, Paul; Hamilton, Antonia; Hirsch, Joy; (2022) Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal. Neurophotonics , 9 (2) , Article 025001. 10.1117/1.NPh.9.2.025001. Green open access

[thumbnail of Hakim_025001_1.pdf]
Preview
Text
Hakim_025001_1.pdf - Published Version

Download (3MB) | Preview

Abstract

SIGNIFICANCE: There is a longstanding recommendation within the field of fNIRS to use oxygenated ( HbO 2 ) and deoxygenated (HHb) hemoglobin when analyzing and interpreting results. Despite this, many fNIRS studies do focus on HbO 2 only. Previous work has shown that HbO 2 on its own is susceptible to systemic interference and results may mostly reflect that rather than functional activation. Studies using both HbO 2 and HHb to draw their conclusions do so with varying methods and can lead to discrepancies between studies. The combination of HbO 2 and HHb has been recommended as a method to utilize both signals in analysis. AIM: We present the development of the hemodynamic phase correlation (HPC) signal to combine HbO 2 and HHb as recommended to utilize both signals in the analysis. We use synthetic and experimental data to evaluate how the HPC and current signals used for fNIRS analysis compare. APPROACH: About 18 synthetic datasets were formed using resting-state fNIRS data acquired from 16 channels over the frontal lobe. To simulate fNIRS data for a block-design task, we superimposed a synthetic task-related hemodynamic response to the resting state data. This data was used to develop an HPC-general linear model (GLM) framework. Experiments were conducted to investigate the performance of each signal at different SNR and to investigate the effect of false positives on the data. Performance was based on each signal's mean T -value across channels. Experimental data recorded from 128 participants across 134 channels during a finger-tapping task were used to investigate the performance of multiple signals [ HbO 2 , HHb, HbT, HbD, correlation-based signal improvement (CBSI), and HPC] on real data. Signal performance was evaluated on its ability to localize activation to a specific region of interest. RESULTS: Results from varying the SNR show that the HPC signal has the highest performance for high SNRs. The CBSI performed the best for medium-low SNR. The next analysis evaluated how false positives affect the signals. The analyses evaluating the effect of false positives showed that the HPC and CBSI signals reflect the effect of false positives on HbO 2 and HHb. The analysis of real experimental data revealed that the HPC and HHb signals provide localization to the primary motor cortex with the highest accuracy. CONCLUSION: We developed a new hemodynamic signal (HPC) with the potential to overcome the current limitations of using HbO 2 and HHb separately. Our results suggest that the HPC signal provides comparable accuracy to HHb to localize functional activation while at the same time being more robust against false positives.

Type: Article
Title: Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1117/1.NPh.9.2.025001
Publisher version: https://doi.org/10.1117/1.NPh.9.2.025001
Language: English
Additional information: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/).
Keywords: functional near-infrared spectroscopy, hemodynamic response, neuroscience
UCL classification: UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > Div of Psychology and Lang Sciences > Institute of Cognitive Neuroscience
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > Div of Psychology and Lang Sciences
URI: https://discovery.ucl.ac.uk/id/eprint/10149610
Downloads since deposit
82Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item