A strontium optical lattice clock with 1 × 10‾¹⁷uncertainty and measurement of its absolute frequency

Hobson, Richard; Bowden, William; Vianello, Alvise; Silva, Alissa; Baynham, Charles FA; Margolis, Helen S; Baird, Patrick EG; ... Hill, Ian R; + view all (2020) A strontium optical lattice clock with 1 × 10‾¹⁷uncertainty and measurement of its absolute frequency. Metrologia , 57 (6) , Article 065026. 10.1088/1681-7575/abb530. Green open access

[thumbnail of 2005.10857 (1).pdf]
Preview
Text
2005.10857 (1).pdf - Other

Download (2MB) | Preview

Abstract

We present a measurement of the absolute frequency of the 5 s2 1S0 to 5s5p 3P0 transition in 87Sr which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the measurement, and we focus in detail on how its systematic frequency shifts are evaluated with a total fractional uncertainty of 1 × 10−17. Traceability to the International System of Units is provided via comparison to International Atomic Time (TAI). Gathering data over 5- and 15-day periods, with the lattice clock operating on average 74% of the time, we measure the frequency of the transition to be 429 228 004 229 873.1 (5) Hz, which corresponds to a fractional uncertainty of 1 × 10−15. We describe in detail how this uncertainty arises from the intermediate steps linking the optical frequency standard, through our local time scale UTC(NPL), to an ensemble of primary and secondary frequency standards which steer TAI. The calculated absolute frequency of the transition is in good agreement with recent measurements carried out in other laboratories around the world.

Type: Article
Title: A strontium optical lattice clock with 1 × 10‾¹⁷uncertainty and measurement of its absolute frequency
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/1681-7575/abb530
Publisher version: http://dx.doi.org/10.1088/1681-7575/abb530
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: optical clock, SI second, absolute frequency measurement, strontium lattice clock, ACCURACY EVALUATION, LASER, TRANSITION, STANDARD, CAVITY, LEVEL, ATOMS
UCL classification: UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL
URI: https://discovery.ucl.ac.uk/id/eprint/10147641
Downloads since deposit
43Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item