Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis

Gill, Simrat; Bunting, Karina V; Sartini, Claudio; Cardoso, Victor Roth; Ghoreishi, Narges; Uh, Hae-Won; Williams, John A; ... Kotecha, Dipak; + view all (2022) Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis. Heart 10.1136/heartjnl-2021-320417. (In press). Green open access

[thumbnail of Banerjee_Smartphone detection of atrial fibrillation using photoplethysmography_AOP.pdf]
Preview
Text
Banerjee_Smartphone detection of atrial fibrillation using photoplethysmography_AOP.pdf - Published Version

Download (1MB) | Preview

Abstract

OBJECTIVES: Timely diagnosis of atrial fibrillation (AF) is essential to reduce complications from this increasingly common condition. We sought to assess the diagnostic accuracy of smartphone camera photoplethysmography (PPG) compared with conventional electrocardiogram (ECG) for AF detection. METHODS: This is a systematic review of MEDLINE, EMBASE and Cochrane (1980-December 2020), including any study or abstract, where smartphone PPG was compared with a reference ECG (1, 3 or 12-lead). Random effects meta-analysis was performed to pool sensitivity/specificity and identify publication bias, with study quality assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) risk of bias tool. RESULTS: 28 studies were included (10 full-text publications and 18 abstracts), providing 31 comparisons of smartphone PPG versus ECG for AF detection. 11 404 participants were included (2950 in AF), with most studies being small and based in secondary care. Sensitivity and specificity for AF detection were high, ranging from 81% to 100%, and from 85% to 100%, respectively. 20 comparisons from 17 studies were meta-analysed, including 6891 participants (2299 with AF); the pooled sensitivity was 94% (95% CI 92% to 95%) and specificity 97% (96%-98%), with substantial heterogeneity (p<0.01). Studies were of poor quality overall and none met all the QUADAS-2 criteria, with particular issues regarding selection bias and the potential for publication bias. CONCLUSION: PPG provides a non-invasive, patient-led screening tool for AF. However, current evidence is limited to small, biased, low-quality studies with unrealistically high sensitivity and specificity. Further studies are needed, preferably independent from manufacturers, in order to advise clinicians on the true value of PPG technology for AF detection.

Type: Article
Title: Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1136/heartjnl-2021-320417
Publisher version: http://dx.doi.org/10.1136/heartjnl-2021-320417
Language: English
Additional information: http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
Keywords: atrial fibrillation, photoplethysmography, smartphone
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Health Informatics
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
URI: https://discovery.ucl.ac.uk/id/eprint/10145231
Downloads since deposit
56Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item