UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Initial experience of the High-Density Grid catheter in patients undergoing catheter ablation for atrial fibrillation

Papageorgiou, N; Karim, N; Williams, J; Garcia, J; Creta, A; Ang, R; Srinivasan, N; ... Chow, AWC; + view all (2022) Initial experience of the High-Density Grid catheter in patients undergoing catheter ablation for atrial fibrillation. Journal of Interventional Cardiac Electrophysiology , 63 pp. 259-266. 10.1007/s10840-021-00950-y. Green open access

[thumbnail of Lambiase_HD grid Manuscript 30-12-2020R3.pdf]
Preview
Text
Lambiase_HD grid Manuscript 30-12-2020R3.pdf - Accepted Version

Download (983kB) | Preview

Abstract

Purpose: A significant proportion of patients undergoing catheter ablation for atrial fibrillation (AF) experience arrhythmia recurrence. This is mostly due to pulmonary vein reconnection (PVR). Whether mapping using High-Density Wave (HDW) technology is superior to standard bipolar (SB) configuration at detecting PVR is unknown. We aimed to evaluate the efficacy of HDW technology compared to SB mapping in identifying PVR. / Methods: High-Density (HD) multipolar Grid catheters were used to create left atrial geometries and voltage maps in 36 patients undergoing catheter ablation for AF (either due to recurrence of an atrial arrhythmia from previous AF ablation or de novo AF ablation). Nineteen SB maps were also created and compared. Ablation was performed until pulmonary vein isolation was achieved. / Results: Median time of mapping with HDW was 22.3 [IQR: 8.2] min. The number of points collected with HDW (13299.6±1362.8 vs 6952.8±841.9, p<0.001) and used (2337.3±158.0 vs 1727.5±163.8, p<0.001) was significantly higher compared to SB. Moreover, HDW was able to identify more sleeves (16 for right and 8 for left veins), where these were confirmed electrically silent by SB, with significantly increased PVR sleeve size as identified by HDW (p<0.001 for both right and left veins). Importantly, with the use of HDW, the ablation strategy changed in 23 patients (64% of targeted veins) with a significantly increased number of lesions required as compared to SB for right (p=0.005) and left veins (p=0.003). / Conclusion: HDW technology is superior to SB in detecting pulmonary vein reconnections. This could potentially result into a significant change in ablation strategy and possibly to increased success rate following pulmonary vein isolation.

Type: Article
Title: Initial experience of the High-Density Grid catheter in patients undergoing catheter ablation for atrial fibrillation
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s10840-021-00950-y
Publisher version: https://doi.org/10.1007/s10840-021-00950-y
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Atrial fibrillation, Catheter ablation, Pulmonary veins, Electrograms
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Health Informatics
URI: https://discovery.ucl.ac.uk/id/eprint/10141540
Downloads since deposit
104Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item