UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Normal background levels of air and surface mould reserve in UK residential building stock

Aktas, YD; Reeslev, M; Altamirano, H; May, N; D'Ayala, D; (2019) Normal background levels of air and surface mould reserve in UK residential building stock. UCL Open: Environment Preprint: London, UK. Green open access

[thumbnail of aktas_et al_Manuscript-UCLOpenEnv(3).pdf]
Preview
Text
aktas_et al_Manuscript-UCLOpenEnv(3).pdf - Submitted Version

Download (921kB) | Preview

Abstract

This paper reports results obtained from a surface (both visually clean and dirty/dusty surfaces) and active (aggressive) air testing scheme on 140 residential rooms in England, without visible water damage or mould growth, along with a few rooms with visible mould growth/water damage tested for comparison purposes, with the aim of providing background levels of mould in non-water-damaged interiors to benchmark a normal indoor environment, and in turn when there is a need for further investigation, and, possibly, remediation. Air and surface mould was quantified based on the activity of β-N-acetylhexosaminidase (EC 3.2.1.52; NAHA). The obtained readings showed a log-normal distribution. 98% of the samples obtained from visually clean surfaces were equal to or less than 25 relative fluorescence units (RFU), which is suggested to be the higher bound for the range which can be used as a success criterion for surface cleaning/remediation in non-problem buildings. Of samples obtained from visually dirty/dusty surfaces, around 98% were below 450 RFU, which is suggested to define the lower-bound for abnormally high levels of mould, rare even on dirty/dusty surfaces. Similarly, around 98% of the air samples were found to have 1700 RFU or below. Values above 1700 RFU are therefore unlikely in a non-problem indoor environment and can be indicative of a possible problem inducing mould growth. The samples with values below 1700 were further divided into three proposed sub-categories. Finally, these values were compared to those obtained in Denmark in a similar study and are currently used in national standards, and they were found highly congruent, suggesting that local climate regimes and room functions might not be as influential on indoor mould levels, or that the nuances between UK and Denmark in terms of these factors are not strong enough to lead to sizable changes in the typical indoor mould levels in these countries.

Type: Working / discussion paper
Title: Normal background levels of air and surface mould reserve in UK residential building stock
Open access status: An open access version is available from UCL Discovery
DOI: 10.14324/111.444/000020.v1
Publisher version: https://doi.org/10.14324/111.444/000020.v1
Language: English
Additional information: This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY) 4.0 (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
Keywords: mould, surface sampling, active (aggressive) air sampling, NAHA, UK, Denmark, Environmental science, Sustainability in architecture and the built environment
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Civil, Environ and Geomatic Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10139671
Downloads since deposit
23Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item