UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection: Validation for tissue oxygenation studies

SUDAKOU, A; LANGE, F; ISLER, H; LANKA, P; WOJTKIEWICZ, S; SAWOSZ, P; OSTOJIC, D; ... GEREGA, A; + view all (2021) Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection: Validation for tissue oxygenation studies. Biomedical Optics Express , 12 (10) pp. 6629-6650. 10.1364/BOE.431301. Green open access

[thumbnail of Tachtsidis_Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection- Validation for tissue oxygenation studies_VoR.pdf]
Preview
Text
Tachtsidis_Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection- Validation for tissue oxygenation studies_VoR.pdf - Published Version

Download (3MB) | Preview

Abstract

We present and validate a multi-wavelength time-domain near-infrared spectroscopy (TD-NIRS) system that avoids switching wavelengths and instead exploits the full capability of a supercontinuum light source by emitting and acquiring signals for the whole chosen range of wavelengths. The system was designed for muscle and brain oxygenation monitoring in a clinical environment. A pulsed supercontinuum laser emits broadband light and each of two detection modules acquires the distributions of times of flight of photons (DTOFs) for 16 spectral channels (used width 12.5 nm / channel), providing a total of 32 DTOFs at up to 3 Hz. Two emitting fibers and two detection fiber bundles allow simultaneous measurements at two positions on the tissue or at two source-detector separations. Three established protocols (BIP, MEDPHOT, and nEUROPt) were used to quantitatively assess the system's performance, including linearity, coupling, accuracy, and depth sensitivity. Measurements were performed on 32 homogeneous phantoms and two inhomogeneous phantoms (solid and liquid). Furthermore, measurements on two blood-lipid phantoms with a varied amount of blood and Intralipid provide the strongest validation for accurate tissue oximetry. The retrieved hemoglobin concentrations and oxygen saturation match well with the reference values that were obtained using a commercially available NIRS system (OxiplexTS) and a blood gas analyzer (ABL90 FLEX), except a discrepancy occurs for the lowest amount of Intralipid. In-vivo measurements on the forearm of three healthy volunteers during arterial (250 mmHg) and venous (60 mmHg) cuff occlusions provide an example of tissue monitoring during the expected hemodynamic changes that follow previously well-described physiologies. All results, including quantitative parameters, can be compared to other systems that report similar tests. Overall, the presented TD-NIRS system has an exemplary performance evaluated with state-of-the-art performance assessment methods.

Type: Article
Title: Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection: Validation for tissue oxygenation studies
Open access status: An open access version is available from UCL Discovery
DOI: 10.1364/BOE.431301
Publisher version: https://doi.org/10.1364/BOE.431301
Language: English
Additional information: Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10136300
Downloads since deposit
32Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item