Understanding flame extinction in timber under external heating using high-activation energy asymptotics

Cuevas, JI; Guibaud, A; Maluk, C; Torero, JL; (2022) Understanding flame extinction in timber under external heating using high-activation energy asymptotics. Combustion and Flame , 235 , Article 111645. 10.1016/j.combustflame.2021.111645. Green open access

[thumbnail of CNF-D-21-00419_Revised_manuscript.pdf]
Preview
Text
CNF-D-21-00419_Revised_manuscript.pdf - Accepted Version

Download (1MB) | Preview

Abstract

The present study analyses the flame extinction of timber under different levels of external heating and oxygen contents in the surrounding atmosphere. An existing theoretical framework conceived initially for the analysis of a counter-flow diffusion flame established above the surface of a condensed fuel is extended for charring materials to deliver a fundamental understanding of the self-extinction of timber. This study shows that the energy balance at the burning surface is influenced primarily by the magnitude of external heating conditions, which directly influences the evolution of bulk properties such as flame temperature, location, and stagnation plane position. Variations in the oxygen content had a lesser influence over these bulk properties. For all investigated conditions, the limits of the strain rate range where a flame can be sustained were shown to vary substantially, and critical Damköhler number (Da) analyses were conducted. Blow-off at high strain rates (low Da) occurs for all investigated conditions. The value of this critical Da decreases when increasing either the magnitude of the external heating or the oxygen content as flame temperature increases. Quenching at low strain rates (high Da) is only found for sufficiently low magnitudes of external heating. There, the associated critical Da increases when increasing either the external heating or the oxygen content. Above a certain degree of external heating, the flame can be theoretically sustained even at infinitely-low strain rates. By comparing these results to experimental data, the experimental critical Da at quenching was found to behave like the theoretical results but with a lower sensitivity to variations in the parameters studied. To account for this discrepancy, a fuel dilution parameter is introduced to incorporate the complex dependencies of timber decomposition and surface reactions not captured by the theoretical framework.

Type: Article
Title: Understanding flame extinction in timber under external heating using high-activation energy asymptotics
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.combustflame.2021.111645
Publisher version: https://doi.org/10.1016/j.combustflame.2021.111645
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Flame extinction, Timber, Counter-flow, Damköhler number, Asymptotic analysis
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Civil, Environ and Geomatic Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10135308
Downloads since deposit
30Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item