Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors

Tsai, Y-J; Bousse, A; Arridge, S; Stearns, CW; Hutton, BF; Thielemans, K; (2021) Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors. IEEE Transactions on Radiation and Plasma Medical Sciences , 5 (3) pp. 362-372. 10.1109/trpms.2020.3025540. Green open access

[thumbnail of journal_submission_on_joint_reconstruction.pdf]
Preview
Text
journal_submission_on_joint_reconstruction.pdf - Accepted Version

Download (969kB) | Preview

Abstract

Two algorithms for solving misalignment issues in penalized PET/CT reconstruction using anatomical priors are proposed. Both approaches are based on a recently published joint motion estimation and image reconstruction method. The first approach deforms the anatomical image to align it with the functional one while the second approach deforms both images to align them with the measured data. Our current implementation alternates between alignment estimation and image reconstruction. We have chosen parallel level sets (PLSs) as a representative anatomical penalty, incorporating a spatially variant penalty strength. The performance was evaluated using simulated nontime-of-flight data generated with an XCAT phantom in the thorax region. We used the attenuation map in the anatomical prior. The results demonstrated that both methods can estimate the misalignment and deform the anatomical image accordingly. However, the performance of the first approach depends highly on the workflow of the alternating process. The second approach shows a faster convergence rate to the correct alignment and is less sensitive to the workflow. The presence of anatomical information improves the convergence rate of misalignment estimation for the second approach but slow it down for the first approach. Both approaches show improved performance in misalignment estimation as the data noise level decreases.

Type: Article
Title: Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors
Open access status: An open access version is available from UCL Discovery
DOI: 10.1109/trpms.2020.3025540
Publisher version: https://doi.org/10.1109/TRPMS.2020.3025540
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Anatomical prior, misalignment estimation, penalized image reconstruction
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Computer Science
URI: https://discovery.ucl.ac.uk/id/eprint/10128563
Downloads since deposit
39Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item