UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Dextran- Versus Crystalloid-Based Prime in Cardiac Surgery: A Prospective Randomized Pilot Study

Barbu, M; Kolsrud, O; Ricksten, S-E; Dellgren, G; Zetterberg, H; Blennow, K; Björk, K; ... Jeppsson, A; + view all (2020) Dextran- Versus Crystalloid-Based Prime in Cardiac Surgery: A Prospective Randomized Pilot Study. The Annals of Thoracic Surgery , 110 (5) pp. 1541-1547. 10.1016/j.athoracsur.2020.03.031. Green open access

[thumbnail of 1-s2.0-S0003497520305439-main.pdf]
Preview
Text
1-s2.0-S0003497520305439-main.pdf - Accepted Version

Download (4MB) | Preview

Abstract

BACKGROUND: The optimum priming fluid for the cardiopulmonary bypass (CPB) circuit is still debated. We compared a new hyperoncotic priming solution containing dextran 40, which has an electrolyte composition that mimics extracellular fluid, with a standard crystalloid-based prime. METHODS: Eighty cardiac surgery patients were included in this double-blind randomized single-centre study. The patients were randomized to either a dextran-based prime or a crystalloid prime containing Ringer acetate and mannitol. The primary endpoint was colloid oncotic pressure (COP) in serum during CPB. Secondary endpoints included fluid balance, bleeding and transfusion requirements, pulmonary function, hemolysis, systemic inflammation, and markers of renal, hepatic, myocardial, and brain injury. Blood samples were collected before, during, and after CPB. RESULTS: COP was higher in the dextran group than in the crystalloid prime group on CPB (18.8±2.9 vs. 16.4±2.9 mmHg, p<0.001) and 10 min after CPB (19.2±2.7 vs. 16.8±2.9 mmHg, p<0.001). Patients in the dextran group required less intravenous fluid during CPB (1090±499 vs. 1437±543 ml; p=0.003) and net fluid balance was less positive 12h after surgery (+1,431±741 vs. +1,901±922 ml; p=0.014). Plasma free hemoglobin was significantly lower in the dextran group 2h after CPB (0.18±0.11 vs 0.41±0.33, p=0.001). There were no significant differences in bleeding, transfusion requirements, organ function, systemic inflammation, or brain and myocardial injury markers between the groups at any time point. CONCLUSIONS: Our results suggest that a hyperoncotic dextran-based priming solution preserves intraoperative COP compared to crystalloid prime. Larger studies with clinically valid endpoints are necessary to evaluate hyperoncotic prime solutions further.

Type: Article
Title: Dextran- Versus Crystalloid-Based Prime in Cardiac Surgery: A Prospective Randomized Pilot Study
Location: Netherlands
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.athoracsur.2020.03.031
Publisher version: https://doi.org/10.1016/j.athoracsur.2020.03.031
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Cardiopulmonary bypass, cardiac surgery, colloids
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Neurodegenerative Diseases
URI: https://discovery.ucl.ac.uk/id/eprint/10096835
Downloads since deposit
182Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item