Havariyoun, G; Vittoria, FA; Hagen, CK; Basta, D; Kallon, GK; Endrizzi, M; Massimi, L; ... Olivo, A; + view all (2019) A compact system for intraoperative specimen imaging based on edge illumination X-ray phase contrast. Physics in Medicine and Biology , 64 (23) , Article 235005. 10.1088/1361-6560/ab4912. Green open access

[thumbnail of Astolfo_Havariyoun_2019_Phys._Med._Biol._64_235005.pdf]
Preview
Text
Astolfo_Havariyoun_2019_Phys._Med._Biol._64_235005.pdf

Download (1MB) | Preview

Abstract

A significant number of patients receiving breast-conserving surgery (BCS) for invasive carcinoma and ductal carcinoma in situ (DCIS) may need reoperation following tumor-positive margins from final histopathology tests. All current intraoperative margin assessment modalities have specific limitations. As a first step towards the development of a compact system for intraoperative specimen imaging based on edge illumination X-ray phase contrast, we prove that the system's dimensions can be reduced without affecting imaging performance. We analysed the variation in noise and contrast to noise ratio (CNR) with decreasing system length using the edge illumination X-ray phase contrast imaging setup. Two (planar) and three (computed tomography (CT)) dimensional imaging acquisitions of custom phantoms and a breast tissue specimen were made. Dedicated phase retrieval algorithms were used to separate refraction and absorption signals. A 'single-shot' retrieval method was also used, to retrieve thickness map images, due to its simple acquisition procedure and reduced acquisition times. Experimental results were compared to numerical simulations where appropriate. The relative contribution of dark noise signal in integrating detectors is significant for low photon count statistics acquisitions. Under constant exposure factors and magnification, a more compact system provides an increase in CNR. Superior CNR results were obtained for refraction and thickness map images when compared to absorption images. Results indicate that the 'single-shot' acquisition method is preferable for a compact CT intraoperative specimen scanner; it allows for shorter acquisition times and its combination of the absorption and refraction signals ultimately leads to a higher contrast. The first CT images of a breast specimen acquired with the compact system provided promising results when compared to those of the longer length system.

Type: Article
Title: A compact system for intraoperative specimen imaging based on edge illumination X-ray phase contrast
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/1361-6560/ab4912
Publisher version: https://doi.org/10.1088/1361-6560/ab4912
Language: English
Additional information: Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
Keywords: CT phase contrast imaging, edge illumination phase contrast imaging, intraoperative imaging, phase contrast imaging, x-ray imaging, x-ray phase contrast imaging
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10082558
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item