Strain elastography for noninvasive assessment of liver fibrosis: A prospective study with histological comparison

Fang, C; Virdee, S; Jacob, J; Rufai, O; Agarwal, K; Quaglia, A; Quinlan, DJ; (2019) Strain elastography for noninvasive assessment of liver fibrosis: A prospective study with histological comparison. Ultrasound , 27 (4) pp. 262-271. 10.1177/1742271X19862836. Green open access

[thumbnail of Jacob_Blind manuscript_cleancopy.pdf]
Preview
Text
Jacob_Blind manuscript_cleancopy.pdf - Accepted Version

Download (293kB) | Preview

Abstract

The aim of this study was to prospectively evaluate the diagnostic performance of strain elastography for the assessment of liver fibrosis in patients with chronic liver disease using Ishak (0–6) histology stage as a reference standard. Ninety-eight consecutive patients with suspected chronic liver disease scheduled for liver biopsy (n = 78) or histologically confirmed cirrhosis (n = 20) were enrolled. Liver fibrosis Index (LF Index) calculated by strain elastography, liver stiffness by transient elastography and serum fibrosis markers (aspartate aminotransferase-to-platelet ratio index and King’s Score) were measured. Spearman’s correlation coefficient between the LF Index, liver stiffness, serum fibrosis markers and fibrosis stage were calculated and compared using areas under the receiver-operating characteristics (AUROCs) curves. Among 73 patients who underwent strain elastography, there was weak correlation between fibrosis stage and the LF Index (Spearman’s: ρ = 0.385 for Ishak score; P = 0.001). Among 52 patients who underwent strain elastography and transient elastography, the AUROC values using LF Index, transient elastography, aspartate aminotransferase-to-platelet ratio index and King’s Score for diagnosing significant fibrosis (Ishak score ≥ 3) were 0.79, 0.87, 0.86 and 0.85, respectively (P < 0.0001) and for diagnosing severe fibrosis/cirrhosis (Ishak score ≥ 5) were 0.83, 0.94, 0.92 and 0.92, respectively (P < 0.0001). When comparing the diagnostic performance using LF Index, transient elastography, aspartate aminotransferase-to-platelet ratio index and King’s Score, transient elastography shows a significantly higher AUROC value than LF Index in detecting severe fibrosis (P = 0.0149). The diagnostic performance of LF Index calculated by strain elastography was not statistically significantly different to the other noninvasive tests for the assessment of significant liver fibrosis but inferior to transient elastography for the assessment of severe fibrosis/cirrhosis.

Type: Article
Title: Strain elastography for noninvasive assessment of liver fibrosis: A prospective study with histological comparison
Open access status: An open access version is available from UCL Discovery
DOI: 10.1177/1742271X19862836
Publisher version: https://doi.org/10.1177/1742271X19862836
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Liver, ultrasound, real-time elastography, liver fibrosis, strain elastography
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Cancer Institute
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Respiratory Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/10080481
Downloads since deposit
108Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item