UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Diffusion-weighted (DW) MRI in lung cancers: ADC test-retest repeatability

Weller, A; Papoutsaki, MV; Waterton, JC; Chiti, A; Stroobants, S; Kuijer, J; Blackledge, M; ... deSouza, NM; + view all (2017) Diffusion-weighted (DW) MRI in lung cancers: ADC test-retest repeatability. European Radiology , 27 (11) pp. 4552-4562. 10.1007/s00330-017-4828-6. Green open access

[thumbnail of Papoutsaki_AAM_emss-79622.pdf]
Preview
Text
Papoutsaki_AAM_emss-79622.pdf - Accepted Version

Download (1MB) | Preview

Abstract

Purpose: To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. // Methods: Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800smm-2). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. // Results: Whole-tumour ADC values ranged from 0.66-1.94x10-3mm2s-1 (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7–9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9–5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson’s R2 = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. // Conclusion: A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change.

Type: Article
Title: Diffusion-weighted (DW) MRI in lung cancers: ADC test-retest repeatability
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s00330-017-4828-6
Publisher version: https://doi.org/10.1007/s00330-017-4828-6
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Lung Cancer, Apparent Diffusion Coefficient (ADC), Repeatability, Reproducibility, Diffusion-weighted MRI
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
URI: https://discovery.ucl.ac.uk/id/eprint/10079437
Downloads since deposit
106Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item