UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Haemodynamic alterations after percutaneous valve implantation

Salmonsmith, Jacob Andrew; (2019) Haemodynamic alterations after percutaneous valve implantation. Doctoral thesis (Ph.D), UCL (University College London). Green open access

[thumbnail of Final Thesis Jacob Salmonsmith PDF.pdf]
Preview
Text
Final Thesis Jacob Salmonsmith PDF.pdf - Accepted Version

Download (86MB) | Preview

Abstract

Many patients who suffer from aortic valve dysfunction are too weak to be eligible for valve replacement via surgery, due to co-morbidities and old age. Transcatheter aortic valve (TAV) implantation has been developed as an alternative to surgery, enabling replacement of the dysfunctional valve percutaneously. However, the inability to remove the native leaflets leads to the bioprosthetic being held in place inside a pseudo-cylindrical structure. The passive nature of heart valves means the surrounding fluid environment’s dynamics are critical in producing optimum performance, and would ideally be returned to the healthy, physiological state. The association of TAVs with thrombotic events, such as strokes, has not yet been fully explained. A pulse duplicator and particle image velocimetry were used to model and characterise the flow fields of a healthy, physiological aortic root and valve, which was then compared to those resulting from a number of typical post- surgical outcomes, identifying the fluid mechanisms promoted by the root geometry to optimise the ejection and closing phases of the cardiac cycle, and revealing the importance of an optimal integration of valve and root architecture, and characterising common post-surgical environments. The same techniques were then used to examine the flow dynamics of the region following TAV implantation, revealing the effect of TAV alignment with its hosts’ commissures, and how the presence of native leaflets, commonly omitted from in vitro TAV testing, affect the valve performance. Slow and stagnant flow was observed within the sinuses due to the native leaflets, whilst global valve performance was broadly unaffected, and omission of the native leaflets resulted in improved haemodynamic performance. A model of coronary arteries was incorporated into the benchtop simulation, revealing increase of flow in the upper coronary sinuses, but flow at the base of all sinuses remained very slow following TAV implantation. The elucidation of this stagnation, associated with thrombotic events, provides an explanation for the increased levels of thrombotic-associated pathologies following TAV implantation.

Type: Thesis (Doctoral)
Qualification: Ph.D
Title: Haemodynamic alterations after percutaneous valve implantation
Event: UCL (University College London)
Open access status: An open access version is available from UCL Discovery
Language: English
Additional information: Copyright © The Author 2019. Original content in this thesis is licensed under the terms of the Creative Commons Attribution 4.0 International (CC BY 4.0) Licence (https://creativecommons.org/licenses/by/4.0/). Any third-party copyright material present remains the property of its respective owner(s) and is licensed under its existing terms.
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering
URI: https://discovery.ucl.ac.uk/id/eprint/10077434
Downloads since deposit
60Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item