UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Extracting impedance changes from a frequency multiplexed signal during neural activity in sciatic nerve of rat: preliminary study in-vitro

Hope, J; Aristovich, KY; Chapman, CAR; Volschenk, A; Vanholsbeeck, F; McDaid, A; (2019) Extracting impedance changes from a frequency multiplexed signal during neural activity in sciatic nerve of rat: preliminary study in-vitro. Physiological Measurement , 40 (3) , Article 034006. 10.1088/1361-6579/ab0c24. Green open access

[thumbnail of Hope+et+al_2019_Physiol._Meas._10.1088_1361-6579_ab0c24.pdf]
Preview
Text
Hope+et+al_2019_Physiol._Meas._10.1088_1361-6579_ab0c24.pdf - Accepted Version

Download (2MB) | Preview

Abstract

OBJECTIVE: Establish suitable frequency spacing and demodulation steps to use when extracting impedance changes from frequency division multiplexed (FDM) carrier signals in peripheral nerve.
 Approach: Experiments were performed in-vitro on cadavers immediately following euthanasia. Neural activity was evoked via stimulation of nerves in the hind paw, while carrier signals were injected, and recordings obtained, with a dual ring nerve cuff implanted on the sciatic nerve. Frequency analysis of recorded compound action potentials (CAPs) and extracted impedance changes, with the latter obtained using established demodulation methods, were used to determine suitable frequency spacing of carrier signals, and bandpass filter (BPF) bandwidth and order, for a frequency multiplexed signal.
 Main results: CAPs and impedance changes were dominant in the frequency band 200 to 500 Hz and 100 to 200 Hz, respectively. A Tukey window was introduced to remove ringing from Gibbs phenomena. A +/- 750 Hz BPF bandwidth was selected to encompass 99.99% of the frequency power of the impedance change. Modelling predicted a minimum BPF order of 16 for 2 kHz spacing, and 10 for 4 kHz spacing, were required to avoid ringing from the neighbouring carrier signal, while FDM experiments verified BPF orders of 12 and 8, respectively, were required. With a notch filter centred on the neighbouring signal, a BPF order of at least 6 or 4 was required for 2 and 4 kHz, respectively.
 Significance: The results establish drive frequency spacing and demodulation settings for use in FDM electrical impedance tomography (EIT) experiments, as well as a method for their selection, and, for the first time, demonstrates the viability of FDM-EIT of neural activity on peripheral nerve, which will be a central aspect of future real-time neural-EIT systems and EIT-based neural prosthetics interfaces.

Type: Article
Title: Extracting impedance changes from a frequency multiplexed signal during neural activity in sciatic nerve of rat: preliminary study in-vitro
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/1361-6579/ab0c24
Publisher version: https://doi.org/10.1088/1361-6579/ab0c24
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: electrical impedance, electrical impedance tomography, imaging, neural imaging, neural prosthetics
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10070053
Downloads since deposit
113Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item