Non-invasive measurement of hepatic venous oxygen saturation (ShvO₂) with quantitative susceptibility mapping in normal mouse liver and livers bearing colorectal metastases

Finnerty, E; Ramasawmy, R; O'Callaghan, J; Connell, J; Lythgoe, M; Shmueli, K; Thomas, D; (2017) Non-invasive measurement of hepatic venous oxygen saturation (ShvO₂) with quantitative susceptibility mapping in normal mouse liver and livers bearing colorectal metastases. BioRxiv: Cold Spring Harbor, NY, USA. Green open access

[thumbnail of Walker-Samuel_Non-invasive measurement of hepatic venous oxygen saturation (ShvO2)_AAM.pdf]
Preview
Text
Walker-Samuel_Non-invasive measurement of hepatic venous oxygen saturation (ShvO2)_AAM.pdf - Accepted Version

Download (609kB) | Preview

Abstract

PURPOSE: The purpose of this prospective study was to investigate the potential of QSM to noninvasively measure hepatic venous oxygen saturation (ShvO2). Materials & Methods: All animal studies were performed in accordance with the UK Home Office Animals Science Procedures Act (1986) and UK National Cancer Research Institute (NCRI) guidelines. QSM data was acquired from a cohort of mice (n=10) under both normoxic (medical air, 21% O2/balance N), and hyperoxic conditions (100% O2). Susceptibility measurements were taken from large branches of the portal and hepatic vein under each condition and were used to calculate venous oxygen saturation in each vessel. Blood was extracted from the IVC of three mice under norm- and hyperoxic conditions, and oxygen saturation was measured using a blood gas analyser to act as a gold standard. QSM data was also acquired from a cohort of mice bearing colorectal liver metastases (CRLM). SvO2 was calculated from susceptibility measurements made in the portal and hepatic veins, and compared to the healthy animals. RESULTS: SvO2 calculated from QSM measurements showed a significant increase of 14.93% in the portal vein (p < 0.05), and an increase of 21.39% in the hepatic vein (p < 0.01). Calculated results showed excellent agreement with those from the blood gas analyser (26.14% increase). ShvO2 was significantly lower in the disease cohort (30.18 ± 11.6%), than the healthy animals (52.67 ± 17.8%) (p < 0.05), but differences in the portal vein were not significant. CONCLUSION: QSM is a feasible tool for non-invasively measuring hepatic venous oxygen saturation and can detect differences in oxygen consumption in livers bearing colorectal metastases.

Type: Working / discussion paper
Title: Non-invasive measurement of hepatic venous oxygen saturation (ShvO₂) with quantitative susceptibility mapping in normal mouse liver and livers bearing colorectal metastases
Open access status: An open access version is available from UCL Discovery
DOI: 10.1101/193656
Publisher version: https://doi.org/10.1101/193656
Language: English
Additional information: This version is the version of record. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
URI: https://discovery.ucl.ac.uk/id/eprint/10068346
Downloads since deposit
32Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item