UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Sources and magnitude of error in preparing morphine infusions for nurse-patient controlled analgesia in a UK paediatric hospital

Rashed, AN; Tomlin, S; Aguado, V; Forbes, B; Whittlesea, C; (2016) Sources and magnitude of error in preparing morphine infusions for nurse-patient controlled analgesia in a UK paediatric hospital. International Journal of Clinical Pharmacy , 38 (5) pp. 1069-1074. 10.1007/s11096-016-0369-3. Green open access

[thumbnail of Rashed_IJCP-D-15-00604R2-Morphine infusion for N-PCA_manuscript-Revised Final 20160718-Cleanversion.pdf]
Preview
Text
Rashed_IJCP-D-15-00604R2-Morphine infusion for N-PCA_manuscript-Revised Final 20160718-Cleanversion.pdf - Accepted Version

Download (193kB) | Preview

Abstract

Background Administering nurse/patient controlled analgesia (N/PCA) to children requires complex dose calculations and multiple manipulations to prepare morphine solutions in 50 mL syringes for administration by continuous infusion with additional boluses. Objective To investigate current practice and accuracy during preparation of morphine N/PCA infusions in hospital theatres and wards at a UK children's hospital. Methods Direct observation of infusion preparation methods and morphine concentration quantification using UV-Vis spectrophotometry. The British Pharmacopoeia specification for morphine sulphate injection drug content (±7.5 %) was used as a reference limit. Results Preparation of 153 morphine infusions for 128 paediatric patients was observed. Differences in preparation method were identified, with selection of inappropriate syringe size noted. Lack of appreciation of the existence of a volume overage (i.e. volume in excess of the nominal volume) in morphine ampoules was identified. Final volume of the infusion was greater than the target (50 mL) in 33.3 % of preparations. Of 78 infusions analysed, 61.5 % had a morphine concentration outside 92.5-107.5 % of label strength. Ten infusions deviated by more than 20 %, with one by 100 %. Conclusions Variation in morphine infusion preparation method was identified. Lack of appreciation of the volume overage in ampoules, volumetric accuracy of different syringe sizes and ability to perform large dilutions of small volumes were sources of inaccuracy in infusion concentration, resulting in patients receiving morphine doses higher or lower than prescribed.

Type: Article
Title: Sources and magnitude of error in preparing morphine infusions for nurse-patient controlled analgesia in a UK paediatric hospital
Location: Netherlands
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s11096-016-0369-3
Publisher version: https://doi.org/10.1007/s11096-016-0369-3
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Analgesia, Children, Medication Error, Morphine, Nurse, Opioid intravenous infusions, Paediatrics, Preparation, United Kingdom, Analgesia, Patient-Controlled, Analgesics, Opioid, Child, Child, Preschool, Dose-Response Relationship, Drug, Female, Hospitals, Pediatric, Humans, Infusions, Intravenous, Male, Medication Errors, Morphine, Nurse's Role, United Kingdom
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences > UCL School of Pharmacy
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences > UCL School of Pharmacy > Practice and Policy
URI: https://discovery.ucl.ac.uk/id/eprint/10061269
Downloads since deposit
368Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item