Kitsos, V;
Schormans, M;
Demosthenous, A;
Liu, X;
(2018)
Asymmetrical Sensing Configuration for Improved Sensitivity in Calorimetric High Flow Measurements in Constant Power Mode.
In:
2018 IEEE SENSORS.
IEEE
Preview |
Text
Kitsos_Asymmetrical Sensing Configuration for Improved Sensitivity in Calorimetric High Flow Measurements in Constant Power Mode_AAM.pdf - Accepted Version Download (795kB) | Preview |
Abstract
This work compares the resolution of calorimetric flow sensors in constant power mode using symmetrically located sensing elements to those using asymmetrical locations, for flow rates higher than the turn-over point. The experimental results show that the resolution can be improved up to six times by placing the temperature sensors in unequal distances, for the same power consumption.
Type: | Proceedings paper |
---|---|
Title: | Asymmetrical Sensing Configuration for Improved Sensitivity in Calorimetric High Flow Measurements in Constant Power Mode |
Event: | 2018 IEEE SENSORS, 28-31 October 2018, New Delhi, India |
ISBN-13: | 978-1-5386-4707-3 |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1109/ICSENS.2018.8589793 |
Publisher version: | https://doi.org/10.1109/ICSENS.2018.8589793 |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Temperature sensors , Heating systems , Temperature measurement , Fluid flow measurement , Topology |
UCL classification: | UCL UCL > Provost and Vice Provost Offices UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Electronic and Electrical Eng |
URI: | https://discovery.ucl.ac.uk/id/eprint/10055744 |




Archive Staff Only
![]() |
View Item |