UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

The ATHENA X-ray Integral Field Unit (X-IFU)

Barret, D; Lam Trong, T; Den Herder, JW; Piro, L; Cappi, M; Houvelin, J; Kelley, R; ... Cobo, B; + view all (2018) The ATHENA X-ray Integral Field Unit (X-IFU). In: Proceedings of SPIE Astronomical Telescopes + Instrumentation 2018. (pp. 106991G). SPIE: Austin, Texas, United States. Green open access

[thumbnail of Barret_VoE.pdf]
Preview
Text
Barret_VoE.pdf - Published Version

Download (1MB) | Preview

Abstract

The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ∼ 5" pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at ∼ 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 μm. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of ∼ 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (< 50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. A factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.

Type: Proceedings paper
Title: The ATHENA X-ray Integral Field Unit (X-IFU)
Event: SPIE Astronomical Telescopes + Instrumentation 2018
ISBN-13: 9781510619517
Open access status: An open access version is available from UCL Discovery
DOI: 10.1117/12.2312409
Publisher version: https://doi.org/10.1117/12.2312409
Language: English
Additional information: © 2018 SPIE. This version is the version of record. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences > Dept of Space and Climate Physics
URI: https://discovery.ucl.ac.uk/id/eprint/10055625
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item