UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Validation of 3D Model-Based Maximum-Likelihood Estimation of Normalisation Factors for Partial Ring Positron Emission Tomography

Niknejad, T; Tavernier, S; Varela, J; Thielemans, K; (2016) Validation of 3D Model-Based Maximum-Likelihood Estimation of Normalisation Factors for Partial Ring Positron Emission Tomography. In: Proceedings of 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD). IEEE: Strasbourg, France. Green open access

[thumbnail of Validation of 3D model-based maximum-likelihood estimation of normalisation.pdf]
Preview
Text
Validation of 3D model-based maximum-likelihood estimation of normalisation.pdf - Accepted Version

Download (4MB) | Preview

Abstract

The next generation of organ specific Positron Emission Tomography (PET) scanners, e.g. for breast imaging, will use partial ring geometries. We propose a component-based Maximum-Likelihood (ML) estimation of normalisation factors for 3D PET data reconstruction applicable to partial ring geometries. This method is based on the Software for Tomographic Image Reconstruction (STIR) for full ring PET and is validated for a stationary partial ring scanner. The model includes the estimation for crystal efficiencies and geometric factors. The algorithm is validated using Maximum Likelihood Estimation Method (MLEM) based 3D reconstruction in STIR using Geant4 Application for Tomographic Emission (GATE) simulation data for full and partial ring scanners and experimental data from a demonstrator with partial ring geometry. The uniformity of the reconstructed images of simulated cylindrical and NEMAIQ phantoms in both scanner geometries and the image of a line source in the partial ring demonstrator is assessed. The results have shown that uniform images in both axial and transaxial directions are obtained after applying the estimated normalisation factors. The accuracy of the algorithm is validated by comparing the normalisation factors between the full and partial ring systems in simulation. We have shown that the estimated normalisation factors are almost identical, even though the separate components are not. This proves that the ML estimation of the 3D normalisation factors is valid and can be applied to the partial ring scanner.

Type: Proceedings paper
Title: Validation of 3D Model-Based Maximum-Likelihood Estimation of Normalisation Factors for Partial Ring Positron Emission Tomography
Event: IEEE Nuclear Science Symposium / Medical Imaging Conference / Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
Location: Strasbourg, FRANCE
Dates: 29 October 2016 - 06 November 2016
Open access status: An open access version is available from UCL Discovery
DOI: 10.1109/NSSMIC.2016.8069577
Publisher version: http://doi.org/10.1109/NSSMIC.2016.8069577
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Positron Emission Tomography (PET), educational PET, small dimension PET, Silicon Photomultiplier (SiPM)
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
URI: https://discovery.ucl.ac.uk/id/eprint/10053833
Downloads since deposit
165Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item