Ellins, EA;
Smith, KE;
Lennon, LT;
Papacosta, O;
Wannamethee, SG;
Whincup, PH;
Halcox, JP;
(2017)
Arterial pathophysiology and comparison of two devices for pulse wave velocity assessment in elderly men: the British regional heart study.
Open Heart
, 4
(2)
, Article e000645. 10.1136/openhrt-2017-000645.
Preview |
Text
e000645.full.pdf - Published Version Download (745kB) | Preview |
Abstract
OBJECTIVE: Vascular disease is highly prevalent in the elderly. This study aimed to evaluate arterial phenotype in elderly men and compare carotid–femoral pulse wave velocity (cfPWV) assessed by two techniques (Sphygmocor (S)and Vicorder (V)). METHODS: 1722 men (72–92 years), participants in the British Regional Heart Study, underwent ultrasound assessment of carotid intima–media thickness (cIMT), carotid distensibility coefficient and presence of carotid plaque. cfPWV and ankle brachial pressure index (ABPI) were also assessed. 123 men returned for between visit reproducibility assessments. RESULTS: Good reproducibility was demonstrated in all measures (Gwet’s agreement=0.8 for plaque, intraclass correlation=0.65 for ABPI and coefficient of variation <13% for all other measures). Measurements were obtained in >90% of men for all measures except cfPWV(S) and ABPI. In 1122 men with both cfPWV(V) and cfPWV(S) data, cfPWV(S) was greater than cfPWV(V) (mean difference=0.23,95%CI 0.10 to 0.37 m/s). cfPWV(V) was higher at low cfPWV values and cfPWV(S) was higher at high cfPWV values. Correlation of V transit time (TT) against S carotid and femoral TT demonstrated that the slope of the regression line for femoral TT was steeper than for carotid TT, resulting in a proportionally greater subtraction of carotid TT from femoral TT at higher PWVs. CONCLUSIONS: Reproducible, satisfactory quality non-invasive measurements of vascular phenotype were obtainable in a large proportion of elderly men. The discrepancy in results between the two PWV measures may partly be due to the differential impact of subtracting carotid TT when deriving cfPWV(S) across the clinical PWV range.
Type: | Article |
---|---|
Title: | Arterial pathophysiology and comparison of two devices for pulse wave velocity assessment in elderly men: the British regional heart study. |
Location: | England |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1136/openhrt-2017-000645 |
Publisher version: | http://dx.doi.org/10.1136/openhrt-2017-000645 |
Language: | English |
Additional information: | © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) license, which permits others to distribute, remix, adapt and build upon this work, for commercial use, provided the original work is properly cited. See: http://creativecommons.org/licenses/by/4.0/ |
Keywords: | Atherosclerosis, cardiovasclar examination, peripheral vascular disease |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Epidemiology and Health UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Epidemiology and Health > Primary Care and Population Health |
URI: | https://discovery.ucl.ac.uk/id/eprint/10043251 |
Archive Staff Only
View Item |