Synchrotron analysis of human organ tissue exposed to implant material

Swiatkowska, I; Mosselmans, FW; Geraki, T; Wyles, CC; Maleszewski, JJ; HENCKEL, J; Sampson, B; ... Hart, A; + view all (2018) Synchrotron analysis of human organ tissue exposed to implant material. Journal of Trace Elements in Medicine and Biology , 46 pp. 128-137. 10.1016/j.jtemb.2017.12.007. Green open access

[thumbnail of Synchrotron Analysis of Human Organ Tissue Exposed to Implant Material- FINAL SUBMITTED VERSION.pdf]
Preview
Text
Synchrotron Analysis of Human Organ Tissue Exposed to Implant Material- FINAL SUBMITTED VERSION.pdf - Accepted Version

Download (844kB) | Preview

Abstract

Background Orthopaedic implants made of cobalt-chromium alloy undergo wear and corrosion that can lead to deposition of cobalt and chromium in vital organs. Elevated cardiac tissue cobalt levels are associated with myocardial injury while chromium is a well-established genotoxin. Though metal composition of tissues surrounding hip implants has been established, few investigators attempted to characterize the metal deposits in systemic tissues of total joint arthroplasty patients. Methods We report the first use of micro-X-ray fluorescence coupled with micro-X-ray absorption spectroscopy to probe distribution and chemical form of cobalt, chromium and titanium in postmortem samples of splenic, hepatic and cardiac tissue of patients with metal-on-polyethylene hip implants (n = 5). Results Majority of the cobalt was in the 2+ oxidation state, while titanium was present exclusively as titanium dioxide, in either rutile or anatase crystal structure. Chromium was found in a range of forms including a highly oxidised, carcinogenic species (CrV/VI), which has never been identified in human tissue before. Conclusions Carcinogenic forms of chromium might arise in vital organs of total joint arthroplasty patients. Further studies are warranted with patients with metal-on-metal implants, which tend to have an increased release of cobalt and chromium compared to metal-on-polyethylene hips.

Type: Article
Title: Synchrotron analysis of human organ tissue exposed to implant material
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.jtemb.2017.12.007
Publisher version: https://doi.org/10.1016/j.jtemb.2017.12.007
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Ortho and MSK Science
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Maths and Physical Sciences
URI: https://discovery.ucl.ac.uk/id/eprint/10042116
Downloads since deposit
257Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item