UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

The efficacy of supplementary sonic irrigation using the EndoActivator® system determined by removal of a collagen film from an ex vivo model

Bryce, G; MacBeth, N; Gulabivala, K; Ng, YL; (2018) The efficacy of supplementary sonic irrigation using the EndoActivator® system determined by removal of a collagen film from an ex vivo model. International Endodontic Journal , 51 (4) pp. 489-497. 10.1111/iej.12870. Green open access

[thumbnail of s1-ln27192411-1812117625-1939656818Hwf-926851642IdV-141776725827192411PDF_HI0001.pdf]
Preview
Text
s1-ln27192411-1812117625-1939656818Hwf-926851642IdV-141776725827192411PDF_HI0001.pdf - Accepted Version

Download (668kB) | Preview

Abstract

Aim: To evaluate the efficacy of sonic irrigation (EndoActivator®) using various polymer tips and power-settings in a stained collagen ex-vivo model. / Methodology: Fifty human, straight single-rooted extracted teeth were prepared to size 40,.08 taper. The roots were split longitudinally; stained collagen applied to the canal surfaces, photographed and re-assembled. The canals were subjected to syringe without supplementary (Group 1, n = 10), or with supplementary sonic (groups 2–5, n = 10) irrigation. EndoActivator® tip sizes (size 15, .02 taper for groups 2 & 3, size 35,.04 taper for groups 4 & 5) and power-settings (Low for groups 2 & 4, high for groups 3 & 5) were tested. After irrigation, the canals were re-photographed and the area of residual stained-collagen was quantified using the UTHSCA Image Tool program (Version 3.0). The data were analysed using Wilcoxon signed rank test and General Linear Mixed Models. / Results: Supplementary sonic irrigation using EndoActivator® resulted in significantly (P < 0.0001) less residual collagen compared with syringe irrigation only. Agitation of irrigant using the large EndoActivator® tip with high-power resulted in significantly less (22.4% – 29.5%) residual collagen compared to other combinations (large-tip/low-power P = 0.001; small-tip/low-power P = 0.01; small-tip/high-power P = 0.04). There was no significant difference amongst the latter three groups (P > 0.5). / Conclusions: Supplementary sonic irrigation using the EndoActivator® system was significantly more effective in removing stained collagen from the canal surface than syringe irrigation alone. EndoActivator® used with large-tip (size 35, .04 taper) and high power-setting in size 40,.08 taper canals was more effective than other combinations.

Type: Article
Title: The efficacy of supplementary sonic irrigation using the EndoActivator® system determined by removal of a collagen film from an ex vivo model
Open access status: An open access version is available from UCL Discovery
DOI: 10.1111/iej.12870
Publisher version: https://doi.org/10.1111/iej.12870
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Eastman Dental Institute
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Eastman Dental Institute > Restorative Dental Sciences
URI: https://discovery.ucl.ac.uk/id/eprint/10028017
Downloads since deposit
230Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item