TY  - JOUR
JF  - Journal of Physics G: Nuclear and Particle Physics
AV  - public
ID  - discovery1447964
N1  - This version is the author accepted manuscript. For information on re-use, please refer to the publisher?s terms and conditions.
Y1  - 2014/02/12/
VL  - 41
A1  - Aprile, E
A1  - Alfonsi, M
A1  - Arisaka, K
A1  - Arneodo, F
A1  - Balan, C
A1  - Baudis, L
A1  - Bauermeister, B
A1  - Behrens, A
A1  - Beltrame, P
A1  - Bokeloh, K
A1  - Brown, A
A1  - Brown, E
A1  - Bruenner, S
A1  - Bruno, G
A1  - Budnik, R
A1  - Cardoso, JMR
A1  - Chen, W-T
A1  - Choi, B
A1  - Colijn, AP
A1  - Contreras, H
A1  - Cussonneau, JP
A1  - Decowski, MP
A1  - Duchovni, E
A1  - Fattori, S
A1  - Ferella, AD
A1  - Fulgione, W
A1  - Gao, F
A1  - Garbini, M
A1  - Ghag, C
A1  - Giboni, K-L
A1  - Goetzke, LW
A1  - Grignon, C
A1  - Gross, E
A1  - Hampel, W
A1  - Itay, R
A1  - Kaether, F
A1  - Kessler, G
A1  - Kish, A
A1  - Lamblin, J
A1  - Landsman, H
A1  - Lang, RF
A1  - Calloch, ML
A1  - Levy, C
A1  - Lim, KE
A1  - Lin, Q
A1  - Lindemann, S
A1  - Lindner, M
A1  - Lopes, JAM
A1  - Lung, K
A1  - Undagoitia, TM
A1  - Massoli, FV
A1  - Fernandez, AJM
A1  - Meng, Y
A1  - Messina, M
A1  - Molinario, A
A1  - Naganoma, J
A1  - Ni, K
A1  - Oberlack, U
A1  - Orrigo, SEA
A1  - Pantic, E
A1  - Persiani, R
A1  - Piastra, F
A1  - Plante, G
A1  - Priel, N
A1  - Rizzo, A
A1  - Rosendahl, S
A1  - Santos, JMFD
A1  - Sartorelli, G
A1  - Schreiner, J
A1  - Schumann, M
A1  - Lavina, LS
A1  - Selvi, M
A1  - Shagin, P
A1  - Simgen, H
A1  - Teymourian, A
A1  - Thers, D
A1  - Vitells, O
A1  - Wang, H
A1  - Weber, M
A1  - Weinheimer, C
N2  - The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
IS  - 3
TI  - Observation and applications of single-electron charge signals in the XENON100 experiment
UR  - http://dx.doi.org/10.1088/0954-3899/41/3/035201
ER  -