UCL logo

UCL Discovery

UCL home » Library Services » Electronic resources » UCL Discovery

Browse by UCL Departments and Centres

Up a level
Export as [feed] Atom [feed] RSS 1.0 [feed] RSS 2.0
Group by: Author | Type
Number of items: 44.

Article

Boone, K; Lewis, A; Holder, DS; (1993) Electrical impedance tomography (EIT) imaging of cortical spreading depression in the anaesthetized rabbit. Journal of Physiology , 473

Duncan, A; Whitlock, TL; Cope, M; Delpy, DT; (1993) Multiwavelength, wideband, intensity-modulated optical spectrometer for near-infrared spectroscopy and imaging. Proceedings of SPIE , 1888 pp. 248-257.

Edwards, A; Richardson, C; van, DZP; Elwell, C; Wyatt, J; (1993) Measurement of haemoglobin flow using near infrared spectroscopy (NIRS). Journal of Applied Physiology , 75 (4) pp. 1884-1889.

Firbank, M; Hiraoka, M; Delpy, DT; (1993) Development of a stable and reproducible tissue-equivalent phantom for use in infrared spectroscopy and imaging. Proceedings of SPIE , 1888 pp. 264-270.

Galgut, PN; Todd-Pokropek, A; (1993) Recurrence of destructive periodontal disease after treatment. A long term study. Bulletin of the Group of International Research Scientists in Stomatology and Odontology , 36 (1) pp. 15-21.

Holder, DS; (1993) EIT and scalp electrodes. Clinical and Physiological Applications of Electrical Impedance Tomography 185 - ?.

Holder, DS; (1993) Localization of functional activity in the brain by electrical impedance tomography (EIT). Electroencephalography and Clinical Neurophysiology , 87 (2) S60 - ?.

Holder, DS; (1993) Opportunities for EIT in the nervous system. Clinical and Physiological Applications of Electrical Impedance Tomography 166 - 175.

Holder, DS; (1993) Physiological constraints to imaging brain function using scalp electrodes. Clinical and Physiological Applications of Electrical Impedance Tomography. D. Holder (ed). UCL Press, London 185 - 200.

Holder, DS; Binnie, CD; Polkey, CE; (1993) Cerebral impedance changes during seizures in human subjects: implications for non-invasive focus detection by electrical impedance tomography (EIT). Brain Topography , 5 331 - ?.

Holder, DS; Brown, BH; (1993) Biomedical applications of EIT: a critical review. Clinical and physiological applications of electrical impedance tomography 6 - 40.

Holder, DS; Temple, AJ; (1993) Effectiveness of the Sheffield EIT system in distinguishing patients with pulmonary pathology from a series of normal subjects. Clinical and physiological applications of electrical impedance tomography 277 - 298.

Holder, DS; Temple, AJ; (1993) Effectiveness of the Sheffield KIT system in. Clinical and Physiological Applications of Electrical Impedance Tomography 277 - ?.

Martinez-Davalos, A; Speller, RD; (1993) A preliminary evaluation of a CCD-based digital x-ray system. Physica Medica , 9 (2-3) pp. 209-213.

Matcher, SJ; Cope, M; Delpy, DT; (1993) Quantification of tissue chromophore concentration via water-peak measurements in near-infrared spectroscopy. Proceedings of SPIE , 1888 pp. 239-247.

Matousek, P; Hester, RE; Moore, JN; Parker, AW; Phillips, D; Toner, WT; Towrie, M; (1993) High repetition rate picosecond time-resolved resonance Raman spectroscopy apparatus. Measurement Science and Technology , 4 (10) pp. 1090-1095. 10.1088/0957-0233/4/10/011.

Neelin, P; Crossman, J; Hawkes, DJ; Ma, Y; Evans, AC; (1993) Validation of an MRI/PET landmark registration method using 3D simulated PET images and point simulations. COMPUT MED IMAGING GRAPH , 17 (895-61) pp. 351-356.

Newell, JC; Isaacson, D; Cheney, M; Saulnier, GJ; Gisser, DG; Goble, JC; Cook, RD; (1993) In vivo impedance images using sinusoidal current patterns. Clinical and Physiological Applications of Electrical Impedance Tomography 277 - 298.

PANKHURST, QA; GIBBS, MRJ; (1993) MOMENT CANTING IN 3D-BASED AMORPHOUS FERROMAGNETS. J PHYS-CONDENS MAT , 5 (19) 3275 - 3288.

Philp, EJ; Cottenden, AM; (1993) Picking and choosing. Nursing Times , 89 (30) pp. 70-83.

Philp, EJ; Cottenden, AM; Ledger, DJ; (1993) Mix and match. Nursing Times , 89 (16) pp. 70-74.

Philp, EJ; Cottenden, AM; Ledger, DJ; (1993) A testing time. Nursing Times , 89 (4) pp. 59-62.

Philp, EJC; A M, L; D, J; (1993) Well disposed? Nursing Times , 89 (16) pp. 65-68.

SPELLER, R; Baba-Hamed, T; (1993) Dual energy probe for tissue characterisation. Physics in medicine and biology , 38 pp. 379-388.

Schweiger, M; Arridge, SR; Delpy, DT; (1993) Application of the finite-element method for the forward and inverse models in optical tomography. Journal of Mathematical Imaging and Vision , 3 (3) pp. 263-283. 10.1007/BF01248356.

Schweiger, M; Arridge, SR; Hiraoka, M; Firbank, M; Delpy, DT; (1993) Comparison of a finite-element forward model with experimental phantom results: application to image reconstruction. Proceedings of SPIE , 1888 pp. 179-190.

Smallwood, RH; Nour, S; Mangnall, YF; Smythe, A; Holder, DS; (1993) Impedance imaging and gastric motility. Clinical and Physiological Applications of Electrical Impedance Tomography 145 - 153.

Takei, Y; Edwards, AD; Lorek, A; Peebles, DM; Belai, A; Cope, M; Delpy, DT; (1993) Effects of N-omega-nitro-L-arginine methyl ester on the cerebral circulation of newborn piglets quantified in vivo by near-infrared spectroscopy. Pediatric Research , 34 pp. 354-359.

Thornburn, P; Cottenden, A; Ledger, D; (1993) Mind the quality. Care Weekly (Apr 15) p. 14.

van der Zee, P; Essenpreis, M; Delpy, DT; (1993) Optical properties of brain tissue. Proceedings of SPIE , 1888 pp. 454-465.

Book

Holder, D; (1993) Clinical and physiological applications of electrical impedance tomography. CRC Press

Book chapter

Cady, EB; Boesch, C; Martin, E; (1993) Magnetic resonance spectroscopy. In: Haddad, J and Saliba, E, (eds.) Perinatal Asphyxia. (pp. 166-194). Springer: Heidelberg.

Report

Martinez-Davalos, A; SPELLER, R; Miller, DJ; Shekhtman, LI; Baru, SE; Khabakhpashev, AG; Ponomorev, OA; (1993) A low-dose digital x-ray system with improved spatial resolution: preliminary evaluation. Publications of the European Organisation for Nuclear Research

Conference item

Beard, PC; Cornforth, RJ; Essenpreis, M; Mills, TN; (1993) Photoacoustic response of post mortem human aorta to 10ns laser pulses. Presented at: Lasers in Medicine - Proceedings of the 11th International Congress, Munich,.

Cady, EB; Lorek, A; Penrice, J; Edwards, AD; Brown, G; Owen-Reece, H; Kirkbride, V; (1993) Proton metabolite spin-spin relaxation and ATP control of the Na+/K+ pump during and after acute cerebral hypoxia-ischaemia in the newborn piglet. Presented at: European Society for Magnetic Resonance in Neuropediatrics 3rd Biennial Meeting, Brussels, Belgium..

Cady, EB; Roth, S; Lorek, A; Wylezinska, M; Aldridge, RF; (1993) A probehead for combined imaging, 1H PRESS, and 31P ISIS absolute quantitation of the brains of newborn human infants. Presented at: Society for Magnetic Resonance in Medicine, 12th Annual Meeting, New York, USA..

Cady, EB; Wyatt, JS; Lorek, A; Penrice, J; Roth, S; Aldridge, RF; Wylezinska, M; (1993) 1H magnetic resonance spectroscopy studies of the brains of newborn infants following perinatal hypoxia-ischaemia. Presented at: British Institute of Radiology "Progress in In Vivo Magnetic Resonance", London, UK..

Cady, EB; Wyatt, JS; Lorek, A; Penrice, J; Roth, S; Aldridge, RF; Wylezinska, M; (1993) Studies by localised 1H magnetic resonance spectroscopy of the brains of normal newborn infants and following perinatal hypoxia-ischaemia. Presented at: European Society for Magnetic Resonance in Neuropediatrics 3rd Biennial Meeting, Brussels, Belgium..

Cady, EB; Wyatt, JS; Lorek, A; Takei, Y; Penrice, J; Edwards, AD; Roth, S; (1993) Delayed cerebral energy failure following recovery from acute hypoxia-ischaemia in the newborn piglet: 31P and 1H magnetic resonance spectroscopy studies. Presented at: European Society for Magnetic Resonance in Neuropediatrics 3rd Biennial Meeting, Brussels, Belgium..

Cady, EB; Wyatt, JS; Takei, Y; Lorek, A; Cooper, C; Edwards, AD; Roth, S; (1993) Cerebral energy failure secondary to acute hypoxia-ischaemia in the newborn pig studied by 1H magnetic resonance spectroscopy. Presented at: Society for Magnetic Resonance Medicine, 12th Annual Meeting, New York, USA..

Cady, EB; Wyatt, JS; Takei, Y; Lorek, A; Edwards, AD; Roth, S; Peebles, D; (1993) 31P magnetic resonance spectroscopy studies of cerebral energy failure secondary to acute hypoxia-ischaemia in the newborn pig. Presented at: Society for Magnetic Resonance in Medicine, 12th Annual Meeting, New York, USA..

Cady, EB; Wyatt, JS; Takei, Y; Lorek, A; Penrice, J; Edwards, AD; Roth, S; (1993) Cerebral energy failure secondary to acute hypoxia-ischaemia: Continuous 7 tesla 31P and 1H magnetic resonance spectroscopy studies over 48 hours. Presented at: British Institute of Radiology "Progress in In Vivo Magnetic Resonance", London, UK..

Wylezinska, M; Cady, EB; (1993) Quality assurance in 31P ISIS absolute quantitation. Presented at: Society for Magnetic Resonance in Medicine, 12th Annual Meeting, New York, USA..

Other

(1993) Chapter 49: Urinary functions and alterations; Chapter 50: Water and electrodes; Chapter 51: Acidosis and Alkalosis. [Translation into Chinese]. McGraw-Hill, New York.

This list was generated on Sun Dec 4 02:56:24 2016 GMT.