UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy

Kang, X; Cannie, MM; Arthurs, OJ; Segers, V; Fourneau, C; Bevilacqua, E; Cos Sanchez, T; ... Jani, JC; + view all (2017) Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy. European Radiology , 27 (8) pp. 3542-3553. 10.1007/s00330-016-4725-4. Green open access

[thumbnail of Arthurs_Post-mortem whole-body magnetic resonance imaging of human fetuses_extracted.pdf]
Preview
Text
Arthurs_Post-mortem whole-body magnetic resonance imaging of human fetuses_extracted.pdf - Accepted Version

Download (2MB) | Preview

Abstract

OBJECTIVE: To prospectively compare diagnostic accuracy of fetal post-mortem whole-body MRI at 3-T vs. 1.5-T. METHODS: Between 2012 and 2015, post-mortem MRI at 1.5-T and 3-T was performed in fetuses after miscarriage/stillbirth or termination. Clinical MRI diagnoses were assessed using a confidence diagnostic score and compared with classical autopsy to derive a diagnostic error score. The relation of diagnostic error for each organ group with gestational age was calculated and 1.5-T with 3-T was compared with accuracy analysis. RESULTS: 135 fetuses at 12-41 weeks underwent post-mortem MRI (followed by conventional autopsy in 92 fetuses). For all organ groups except the brain, and for both modalities, the diagnostic error decreased with gestation (P < 0.0001). 3-T MRI diagnostic error was significantly lower than that of 1.5-T for all anatomic structures and organ groups, except the orbits and brain. This difference was maintained for fetuses <20 weeks gestation. Moreover, 3-T was associated with fewer non-diagnostic scans and greater concordance with classical autopsy than 1.5-T MRI, especially for the thorax, heart and abdomen in fetuses <20 weeks. CONCLUSION: Post-mortem fetal 3-T MRI improves confidence scores and overall accuracy compared with 1.5-T, mainly for the thorax, heart and abdomen of fetuses <20 weeks of gestation. KEY POINTS: • In PM-MRI, diagnostic error using 3-T is lower than that with 1.5-T. • In PM-MRI, diagnostic scan rate is higher using 3-T than 1.5-T. • In PM-MRI, concordance with classical autopsy increases with 3-T. • PM-MRI using 3-T is particularly interesting for thoracic and abdominal organs. • PM-MRI using 3-T is particularly interesting for fetuses < 20 weeks' gestation.

Type: Article
Title: Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy
Location: Germany
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s00330-016-4725-4
Publisher version: http://dx.doi.org/10.1007/s00330-016-4725-4
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: 3-Tesla, Accuracy, Classical post-mortem, Post-mortem MRI, Virtual autopsy
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health > Developmental Neurosciences Dept
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health > Population, Policy and Practice Dept
URI: https://discovery.ucl.ac.uk/id/eprint/1539665