UCL logo

UCL Discovery

UCL home » Library Services » Electronic resources » UCL Discovery

Computation of volume flow in modulated-pressure ceramic injection moulding

Zhang, T; Evans, JRG; (1993) Computation of volume flow in modulated-pressure ceramic injection moulding. Ceramics International , 19 (6) pp. 367-373. 10.1016/0272-8842(93)90026-N.

Full text not available from this repository.

Abstract

The volume of ceramic suspension involved in oscillatory flow through the sprue and runners during modulated hold pressure moulding was calculated using the cooling characteristics of the moulding and the equation of state for the suspension. With single-gated moulds, the displaced volume is limited by the mould dimensions and the compressibility of the suspension. This restricts the heat dissipated from viscous losses in the core of the sprue and hence the extension to sprue solidification time. The calculation facilitates preliminary estimations of heat fluxes. © 1993.

Type: Article
Title: Computation of volume flow in modulated-pressure ceramic injection moulding
DOI: 10.1016/0272-8842(93)90026-N
UCL classification: UCL > School of BEAMS
UCL > School of BEAMS > Faculty of Maths and Physical Sciences
URI: http://discovery.ucl.ac.uk/id/eprint/730870
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item