UCL logo

UCL Discovery

UCL home » Library Services » Electronic resources » UCL Discovery

Conversion of Umbilicial Arterial Doppler Waveforms (UADWs) to Cardiac Cycle Triggering Signals (CCTSs) - A Preparatory Study of On-Line Motion-Gated Three-Dimensional (3D) Fetal Echocardiography

Deng, J; Kalache, KD; Hanson, MA; Peebles, DM; Linney, AD; Lees, WR; Rodeck, CH; (2001) Conversion of Umbilicial Arterial Doppler Waveforms (UADWs) to Cardiac Cycle Triggering Signals (CCTSs) - A Preparatory Study of On-Line Motion-Gated Three-Dimensional (3D) Fetal Echocardiography. Ultrasound in Medicine and Biology , 27 (1) pp. 51-59.

Full text not available from this repository.

Abstract

To remove motions artefacts, a device was built to convert 'noisy' umbilical arterial Doppler waveforms (UADWs) from an ultrasound(US) system into sharp ECG R-wave-like cardiac cycle triggering signals (CCTSs). These CCTSs were then used to gate a simultaneous (online) 3-D acquisition of sectional fetal echocardiograms from another US system. To test the conversion performance, a study was carried out in sheep fetal twins. Pulmonary arterial flow waveforms (PAFWs) from implanted probes were traced, in the meantime, to determine the reference cardiac cycle. Interference caused by running the two nonsynchronised US systems was controlled to three degrees (not-noticeable, moderate and severe) together with high (>/40 cm/s) and low (<40) flow velocities on UADWs. The conversion efficiency, assessed by the percentage of UADWs converted into CCTSs,was in the range of 83% to 100% for not-noticeable and moderated interference,and 0% to 71% for severe interference. The triggering accuracy, assessed by [time lag mean between the onsets of PAFWs and corresponding CCTSs) - (its 99% confidence level)]/ the mean, was 90% to 96% for the not-noticeable interference high and low flow groups and for the moderate interference high flow group; 19-93% for the moderate interference low flow group; and from not obtainable up to 90% for the severe interference groups. The results show that UADWs can be uses as a satisfactory on-line motion-gating source even in the presence of moderated interference. The major problems are from severe interference or moderate interference with low flow velocity, which can be minimised/eliminated by the integration of the individual systems involved

Type: Article
Title: Conversion of Umbilicial Arterial Doppler Waveforms (UADWs) to Cardiac Cycle Triggering Signals (CCTSs) - A Preparatory Study of On-Line Motion-Gated Three-Dimensional (3D) Fetal Echocardiography
Keywords: 3D, accuracy, ACQUISITION, artefacts, Arterial, As, cardiac, confidence, CONVERSION, cycle, DEVICE, DOPPLER, Dynamic three dimensional ultrasound/Fetal heart, echocardiography, efficiency, fetal, fetal echocardiography, flow, groups, integration, Low, Motion, on-line, ONLINE, ONSET, PERCENTAGE, performance, PROBE, PROBES, Problems, pulmonary, RANGE, Result, sheep, signal, signals, simultaneous, SYSTEM, SYSTEMS, Three-dimensional, together, TWIN, Twins, Umbilical, US, Use, VELOCITY, Waveform
UCL classification: UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > The Ear Institute
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Pop Health Sciences > Inst for Women's Health
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Pop Health Sciences > Inst for Women's Health > Maternal and Fetal Medicine
URI: http://discovery.ucl.ac.uk/id/eprint/63215
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item