Esbrand, CJ; Arvanitis, CD; Pani, S; Price, BD; Griffiths, JA; Metaxas, M; ... Speller, RD; + view all (2009) Characterisation of the Components of a Prototype Scanning Intelligent Imaging System for Use in Digital Mammography: The I-ImaS System. In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. (pp. 1419 - 1425). IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC

Full text not available from this repository.

Abstract

The physical performance characteristics of a prototype scanning digital mammography (DM) system have been investigated. The I-ImaS system utilises CMOS MAPS technology promoting on-chip data processing; consequently statistical analysis is therefore achievable in real-time for the purpose of exposure modulation via a feedback mechanism during the image acquisition procedure. The imager employs a dual array of twenty CMOS APS sensing devices each individually coupled to a 100 mu m thick thallium doped structured CsI scintillator. The x-ray performance of the sensors was characterised where the presampled modulation transfer function (MTF), normalised noise power spectrum (NNPS), and the detective quantum efficiency (DQE) was determined. The presampled MTF was measured utilising the slit technique and was found to be 0.1 at 6 lp/mm. The NNPS measured utilising a W/Al target/filter combination hardened with 38 mm PMMA was seen to decrease with increasing exposure as expected and the manifesting DQE was 0.30 at close to zero spatial frequency at an exposure of 1.75 mR. Preliminary image stitching of the individual steps acquired from the scanning system is presented. A conventionally acquired image that is without the implementation of beam modulation or off-line intelligence is compared and contrasted to an intelligently off-line processed image. Results indicate the implementation of real-time intelligence

Type:Proceedings paper
Title:Characterisation of the Components of a Prototype Scanning Intelligent Imaging System for Use in Digital Mammography: The I-ImaS System
Event:Symposium on Radiation Measurements and Applications
Location:Berkeley, CA
Dates:2008-06-02 - 2008-06-05
DOI:10.1109/TNS.2009.2015762
Keywords:CMOS active pixels sensors, data acquisition, detector characterisation, digital mammography, medical imaging, NOISE POWER SPECTRUM, RADIOGRAPHY, DETECTORS, PERFORMANCE, QUALITY
UCL classification:UCL > School of Life and Medical Sciences > Faculty of Medical Sciences > Surgery and Interventional Science (Division of)
UCL > School of BEAMS > Faculty of Engineering Science > Institute of Biomedical Engineering
UCL > School of BEAMS > Faculty of Engineering Science > Medical Physics and Bioengineering

Archive Staff Only: edit this record